1. Si pixel detectors in the detection of EC/EC decay.
- Author
-
Jose, J. M., Čermák, P., Fajt, L., Loaiza, P., Rukhadze, N. I., Shitov, Yu. A., and Štekl, I.
- Subjects
SILICON compounds ,ELECTRON capture ,NUCLEAR counters ,PARTICLES (Nuclear physics) ,BETA decay ,CADMIUM isotopes - Abstract
The SPT collaboration has been investigating the applicability of pixel detectors in the detection of two neutrino double electron capture (2vEC/EC) in
106 Cd. The collaboration has proposed a Silicon Pixel Telescope (SPT) where a pair of Si pixel detectors with enriched Cd foil in the middle forms the detection unit. The Pixel detector gives spatial information along with energy of the particle, thus helps to identify and remove the background signals. Four units of SPT prototype (using 0.5 and 1 mm Si sensors) were fabricated and installed in the LSM underground laboratory, France. Recent progress in the SPT experiment and preliminary results from background measurements are presented. [ABSTRACT FROM AUTHOR]- Published
- 2015
- Full Text
- View/download PDF