1. A randomized prospective mechanistic cardiac magnetic resonance study correlating catheter stability, late gadolinium enhancement and 3 year clinical outcomes in robotically assisted vs. standard catheter ablation.
- Author
-
Arujuna A, Karim R, Zarinabad N, Gill J, Rhode K, Schaeffter T, Wright M, Rinaldi CA, Cooklin M, Razavi R, O'Neill MD, and Gill JS
- Subjects
- Contrast Media, Female, Gadolinium, Humans, Longitudinal Studies, Male, Middle Aged, Prospective Studies, Reproducibility of Results, Sensitivity and Specificity, Statistics as Topic, Treatment Outcome, Atrial Fibrillation pathology, Atrial Fibrillation surgery, Catheter Ablation methods, Magnetic Resonance Imaging, Cine methods, Robotic Surgical Procedures methods, Surgery, Computer-Assisted methods
- Abstract
Aims: To prospectively compare cardiac magnetic resonance late gadolinium enhancement (LGE) findings created by standard vs. robotically assisted catheter ablation lesions and correlate these with clinical outcomes., Methods and Results: Forty paroxysmal atrial fibrillation patients (mean age 54 ± 13.8 years) undergoing first left atrial ablation were randomized to either robotic-assisted navigation (Hansen Sensei(®) X) or standard navigation. Pre-procedural, acute (24 h post-procedure) and late (beyond 3 months) scans were performed with LGE and T2W imaging sequences and percentage circumferential enhancement around the pulmonary vein (PV) antra were quantified. Baseline pre-procedural enhancements were similar in both groups. On acute imaging, mean % encirclements by LGE and T2W signal were 72% and 80% in the robotic group vs. 60% (P = 0.002) and 76%(P = 0.45) for standard ablation. On late imaging, the T2W signal resolved to baseline in both groups. Late gadolinium enhancement remained the predominant signal with 56% encirclement in the robotic group vs. 45% in the standard group (P = 0.04). At 6 months follow-up, arrhythmia-free patients had an almost similar mean LGE encirclement (robotic 64%, standard 60%, P = 0.45) but in recurrences, LGE was higher in the robotic group (43% vs. 30%, P = 0.001). At mean 3 years follow-up, 1.3 procedures were performed in the robotic group compared with 1.9 (P < 0.001) in the standard to achieve a success rate of 80% vs. 75%., Conclusion: Robotically assisted ablation results in greater LGE around the PV antrum. Effective lesions created through improved catheter stability and contact force during initial treatment may have a role in reducing subsequent re-do procedures., (© The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.)
- Published
- 2015
- Full Text
- View/download PDF