1. The value of bronchodilator response in FEV1 and FeNO for differentiating between chronic respiratory diseases: an observational study.
- Author
-
Gong Z, Huang J, Xu G, Chen Y, Xu M, Ma Y, Zhao W, Wang Y, Liang J, Ou C, Liu L, Cai S, and Zhao H
- Subjects
- Humans, Breath Tests, Bronchodilator Agents pharmacology, Bronchodilator Agents therapeutic use, Forced Expiratory Volume, Fractional Exhaled Nitric Oxide Testing, Asthma diagnosis, Asthma drug therapy, Pulmonary Disease, Chronic Obstructive diagnosis, Pulmonary Disease, Chronic Obstructive drug therapy
- Abstract
Background: There is no uniform standard for a strongly positive bronchodilation test (BDT) result. In addition, the role of bronchodilator response in differentiating between asthma, chronic obstructive pulmonary disease (COPD), and asthma-COPD overlap (ACO) in patients with a positive BDT result is unclear. We explored a simplified standard of a strongly positive BDT result and whether bronchodilator response combined with fractional exhaled nitric oxide (FeNO) can differentiate between asthma, COPD, and ACO in patients with a positive BDT result., Methods: Three standards of a strongly positive BDT result, which were, respectively, defined as post-bronchodilator forced expiratory volume in 1-s responses (ΔFEV
1 ) increasing by at least 400 mL + 15% (standard I), 400 mL (standard II), or 15% (standard III), were analyzed in asthma, COPD, and ACO patients with a positive BDT result. Receiver operating characteristic curves were used to determine the optimal values of ΔFEV1 and FeNO. Finally, the accuracy of prediction was verified by a validation study., Results: The rates of a strongly positive BDT result and the characteristics between standards I and II were consistent; however, those for standard III was different. ΔFEV1 ≥ 345 mL could predict ACO diagnosis in COPD patients with a positive BDT result (area under the curve [AUC]: 0.881; 95% confidence interval [CI] 0.83-0.94), with a sensitivity and specificity of 90.0% and 91.2%, respectively, in the validation study. When ΔFEV1 was < 315 mL combined with FeNO < 28.5 parts per billion, patients with a positive BDT result were more likely to have pure COPD (AUC: 0.774; 95% CI 0.72-0.83)., Conclusion: The simplified standard II can replace standard I. ΔFEV1 and FeNO are helpful in differentiating between asthma, COPD, and ACO in patients with a positive BDT result., (© 2024. The Author(s).)- Published
- 2024