1. Correction methodology for the spectral interfering γ-rays overlapping to the analytical peaks used in the analysis of 232Th.
- Author
-
Yücel H, Köse E, Esen AN, and Bor D
- Subjects
- Algorithms, Gamma Rays, Radiation Dosage, Radioisotopes chemistry, Reference Standards, Thorium chemistry, Uranium chemistry, Artifacts, Radioisotopes analysis, Spectrometry, Gamma methods, Thorium analysis, Uranium analysis
- Abstract
In the γ-ray spectrometric analysis of the radionuclides, a correction factor is generally required for the spectral interfering γ-rays in determining the net areas of the analytical peaks because some interfering γ-rays often might contribute to the analytical peaks of interest. In present study, a correction methodology for the spectral interfering γ-rays (CSI) is described. In particular, in the analysis of (232)Th contained in samples, the interfering γ-rays due to (226)Ra, (235)U, (238)U and their decay products often overlap to the peaks of interest from (232)Th decay products, and vise versa. For the validation of the proposed CSI method, several certified reference materials (CRM) containing U and Th were measured by using a 76.5% efficient n-type Ge detector. The required correction factors were quantified for spectral interference, self-absorption and true coincidence summing (TCS) effects for the relevant γ-rays. The measured results indicate that if one ignores the contributions of the interfering γ-rays to the analytical peaks at 583.2 keV of (208)Tl and 727.3 keV of (212)Bi, this leads to a significantly systematic influence on the resulted activities of (232)Th. The correction factors required for spectral interference and TCS effects are estimated to be ∼13.6% and ∼15.4% for 583.2 keV peak. For the 727.3 keV peak, the correction factor is estimated to be ∼15% for spectral interference, and ∼5% for the TCS effects at the presently used detection geometry. On the other hand, the measured results also indicate that ignoring the contribution of the interfering γ-rays to the areas of the analytical peaks at 860.6 keV of (208)Tl, 338.3 and 911.2 keV of (228)Ac does not lead to any significant systematic influence on the (232)Th analysis. Because these factors are remained generally less than ∼5%, i.e., within overall uncertainty limits. The present study also showed that in view of both the spectral interference and TCS effects, the "cleaner" analytical peaks are seen at 338.3 keV (11.25%) and 911.2 keV (26.13%) of (228)Ac when high resolution γ-rays spectrometry was used in the (232)Th activity measurements. Therefore, they can be adopted as the "reference" peaks in the (232)Th analysis., (Copyright © 2011 Elsevier Ltd. All rights reserved.)
- Published
- 2011
- Full Text
- View/download PDF