1. A Comparison of Clinical Outcomes After Total Knee Arthroplasty in Patients Who Have and Do Not Have Self-Reported Nickel Allergy: Matched and Unmatched Cohort Comparisons.
- Author
-
Siljander BR, Chandi SK, Cororaton AD, Debbi EM, McLawhorn AS, Sculco PK, and Chalmers BP
- Subjects
- Humans, Male, Female, Aged, Middle Aged, Treatment Outcome, Osteoarthritis, Knee surgery, Prosthesis Failure, Cohort Studies, Arthroplasty, Replacement, Knee adverse effects, Nickel adverse effects, Self Report, Reoperation statistics & numerical data, Hypersensitivity, Patient Reported Outcome Measures, Knee Prosthesis adverse effects
- Abstract
Background: The impact of a preoperative self-reported nickel allergy in patients undergoing primary total knee arthroplasty (TKA) remains unclear. The aim of this study was to compare the revision rates and outcomes of patients who have a self-reported nickel allergy undergoing primary TKA to patients who do not have a self-reported nickel allergy., Methods: Over 5 years, a total of 284 TKAs in patients who have and 17,735 in patients who do not have a self-reported nickel allergy were performed. Revision rates and differences in preoperative and postoperative patient-reported outcome measures, including Knee Osteoarthritis Outcome Score Joint Replacement (KOOS JR), Visual Analog Scale, Lower Extremity Activity Scale, and the Patient-Reported Outcomes Measurement Information System Mental and Physical Scores, were compared., Results: Survivorship free of all-cause revision at 1 year was similar for patients who have and do not have a self-reported nickel allergy (99.5% [95% CI (confidence interval): 98.6 to 100.0] versus 99.3% [95% CI: 99.1 to 99.4]), P = .49). Patients who have a self-reported nickel allergy undergoing primary TKA had no difference in KOOS JR, Visual Analog Scale, or Lower Extremity Activity Scale scores at 6 weeks and 1 year and slightly worse Patient-Reported Outcomes Measurement Information System mental and physical scores at 6 weeks compared to patients who did not have an allergy. Matched analysis revealed no difference in 6-week or 1-year KOOS, JR scores between patients who did and did not have a self-reported nickel allergy when stratified by implant class (nickel-free versus standard cobalt-chromium) (P = .113 and P = .415, respectively)., Conclusions: Patients who have a self-reported nickel allergy can be advised that, on average, their clinical outcome scores will improve similarly to patients who do not have a self-reported nickel allergy, and revision rates will be similar., (Copyright © 2024 Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF