- Humans, Hip Joint surgery, Cohort Studies, Retrospective Studies, Reproducibility of Results, Acetabulum surgery, Treatment Outcome, Arthroplasty, Replacement, Hip adverse effects, Arthroplasty, Replacement, Hip methods, Hip Prosthesis adverse effects, Robotic Surgical Procedures adverse effects, Developmental Dysplasia of the Hip surgery
- Abstract
Purposes: Due to the morphological diversity of deformities, technical difficulties, improperly designed components, and so on, THA remains a challenging task in dysplastic hips, especially in highly dislocated hips. The purpose of this study was to comprehensively evaluate the clinical outcomes of robot-assisted THA in patients with DDH through a large cohort study, including the precision of acetabular cup positioning, indicators of inflammatory response, indicators of muscle damage, and complications., Methods: We retrospectively analyzed patients with DDH who underwent THA in our prospectively constructed joint registry between August 2018 and August 2022. Finally, 147 manual THAs and 147 robotic-assisted THAs were included in the final analysis. Patient demographics, indicators of inflammation, indicators of muscle damage, operative time, Harris hip scores (HHS), and forgotten joint score (FJS) were recorded for analysis. The precision of the positioning of the acetabular component was assessed with plain radiographs., Results: In the Crowe II/III groups, the reconstructed center of rotation (COR) in the robotic-assisted group was closer to the anatomical COR with less variation than the manual group (absolute horizontal distances of COR 3.5 ± 2.8 vs. 5.4 ± 4.9 mm, p < 0.05; absolute vertical distances of COR 6.4 ± 4.1 vs. 11.7 ± 8.2 mm, p = 0.001). For all Crowe subtypes, the robotic-assisted THA significantly increased the proportion of acetabular cups located in the safety zone within 5° (all p < 0.05). Interleukin-6 and creatine kinase levels were slightly lower and significantly different in the robotic-assisted group at three days postoperatively (all p < 0.05)., Conclusions: Compared to the manual technique, the robot-assisted technique improved the precision and reproducibility of acetabular component positioning, particularly in DDH patients with Crowe types II/III. The robotic-assisted technique did not increase operative time, bleeding, complications, or revision rates, and had a slighter early inflammatory response and muscle damage., (© 2024. The Author(s) under exclusive licence to SICOT aisbl.)
- Published
- 2024
- Full Text
- View/download PDF