1. Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium.
- Author
-
Krane M, Boehm J, Prinzing A, Ziegelmueller J, Holfeld J, and Lange R
- Subjects
- Adolescent, Adult, Aged, Autografts, Female, Heart Valve Prosthesis Implantation, Humans, Male, Middle Aged, Prosthesis Design, Retrospective Studies, Treatment Outcome, Young Adult, Aortic Valve surgery, Aortic Valve Insufficiency surgery, Aortic Valve Stenosis surgery, Bioprosthesis, Heart Valve Prosthesis, Hemodynamics, Pericardium transplantation
- Abstract
Background: Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) offers an alternative treatment modality to overcome drawbacks of conventional prosthetic aortic valve replacement., Methods: Between October 2016 and April 2019, 103 patients underwent surgery. Mean follow-up was 426 ± 270 days. Aortic stenosis was the leading diagnosis in 80 patients (77.7%) and aortic regurgitation in 23 (22.3%), respectively. Mean age was 54.0 ± 16.4 years (range, 13.8-78.5). A bicuspid valve was found in 81 patients (78.6%). Transthoracic echocardiography was performed at discharge and at 6 to 12 months after surgery. During AVNeo surgery valve sizing for an Abbott/St Jude Trifecta bioprosthesis (virtually implanted Trifecta bioprosthesis; St Jude Medical, St Paul, MN) was performed to compare pressure gradients and effective orifice area with published data., Results: Trileaflet aortic valve reconstruction was achieved in all patients. In 38 patients neocommissures were created (36.9%). Mean cross-clamp time was 135 ± 20 minutes. Four patients underwent reoperation; the overall freedom from reoperation was 96.1%. Echocardiographic 6- to 12-months follow-up after surgery was available in 93.8% of patients and did not show any change in hemodynamic parameters compared with discharge. Comparison between AVNeo and virtually implanted Trifecta Bioprosthesis revealed a significantly lower mean pressure gradient (8.5 ± 3.7 mm Hg vs 10.2 ± 2.0 mm Hg, P < .001) and higher mean effective orifice area (2.2 ± 0.7 cm
2 vs 2.1 ± 0.4 cm2 , P = .037) for AVNeo., Conclusions: AVNeo shows low reoperation rates after surgery within the first 2 years. The hemodynamic performance is excellent, and the effective orifice area and mean pressure gradient remain stable within the first year., (Copyright © 2021 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)- Published
- 2021
- Full Text
- View/download PDF