1. Early clinical and procedural outcomes in large series of 34-mm self-expanding transcatheter aortic valve replacement.
- Author
-
Ali Z, Sharma P, Mengesha T, Dalmar A, Ammar KA, Allaqaband SQ, O'Hair DP, Khandheria BK, Jain R, and Bajwa T
- Subjects
- Aged, Aged, 80 and over, Aortic Valve diagnostic imaging, Aortic Valve physiopathology, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis mortality, Aortic Valve Stenosis physiopathology, Female, Hospital Mortality, Humans, Male, Postoperative Complications mortality, Postoperative Complications therapy, Prosthesis Design, Recovery of Function, Retrospective Studies, Risk Factors, Severity of Illness Index, Time Factors, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement mortality, Treatment Outcome, Aortic Valve surgery, Aortic Valve Stenosis surgery, Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement instrumentation
- Abstract
Objectives: We aimed to evaluate early clinical and procedural outcomes with the 34-mm Evolut R transcatheter aortic valve replacement (TAVR) prosthesis., Background: The 34-mm Evolut R (Medtronic, Minneapolis, MN) self-expanding TAVR prosthesis was designed to treat patients with larger annuli., Methods: Clinical, demographic, procedural, and echocardiographic data on consecutive patients who underwent TAVR with a 34-mm Evolut R prosthesis at our institution were collected and analyzed., Results: One hundred ninety-six patients underwent TAVR with this prosthesis from November 2016 to July 2018, a majority (n = 188, 96%) through transfemoral access and with conscious sedation (n = 182, 93%). Mean age, Society of Thoracic Surgery risk score, and follow-up were 82 ± 8 years, 5.4 ± 5%, and 8.2 ± 5.3 months, respectively. Mean aortic valve (AV) peak velocity was 4.0 ± 0.6 m/s, mean AV gradient was 38 ± 13 mmHg, AV area was 0.79 ± 0.23 cm
2 ; calcium score was 3,503 ± 1,970 Agatston units, and perimeter was 85 ± 4.3 mm. Device implantation was successful in all but one patient. Postprocedure mean AV peak velocity, AV mean gradient, and AV area were 1.9 ± 0.4 m/s, 7 ± 3 mmHg, and 2.6 ± 0.7 cm2 , respectively. New pacemaker requirement rate was 16%, and moderate paravalvular leak was present in six patients (3%), which improved to mild in three patients at 6-month follow-up. In-hospital, 30-day, 6-month, and 12-month survival rates were 98%, 96% (hospital discharge), 96% (30-day), 89% (6-month), and 83% (12-month)., Conclusion: These data demonstrate high success and good procedural, echocardiographic, and clinical outcomes of 34-mm Evolut R in patients with large annuli., (© 2019 Wiley Periodicals, Inc.)- Published
- 2020
- Full Text
- View/download PDF