1. Safety of contrast-enhanced ultrasonography in dogs and cats: 488 cases (2002-2011)
- Author
-
Nathalie Rademacher, Pascaline Pey, Stefanie Ohlerth, James C. Brown, Melissa C. Bucknoff, O. Travetti, Robert T. O'Brien, Lorrie Gaschen, Wm. Todd Drost, Jennifer A. Reetz, Jimmy Saunders, Daniela S Alder, Olivier Taeymans, Rachel E. Pollard, Gabriela S. Seiler, Cintia R. Oliveira, Federica Rossi, Miriam M. Shanaman, University of Zurich, Seiler, Gabriela S., Brown, James C., Reetz, Jennifer A., Taeymans, Olivier, Bucknoff, Melissa, Rossi, Federica, Ohlerth, Stefanie, Alder, Daniela, Rademacher, Nathalie, Drost, Wm Tod, Pollard, Rachel E., Travetti, Olga, Pey, Pascaline, Saunders, Jimmy H., Shanaman, Miriam M., Oliveira, Cintia R., O'Brien, Robert T., and Gaschen, Lorrie
- Subjects
medicine.medical_specialty ,10253 Department of Small Animals ,3400 General Veterinary ,Contrast Media ,Cat Diseases ,Dogs ,Retrospective Studie ,Dog ,Stress Echocardiography ,Medicine ,Animals ,Dog Diseases ,Adverse effect ,Cause of death ,Retrospective Studies ,Ultrasonography ,CATS ,General Veterinary ,medicine.diagnostic_test ,Animal ,business.industry ,Incidence (epidemiology) ,Medical record ,Cat ,Retrospective cohort study ,Cat Disease ,Case-Control Studies ,Cats ,Veterinary (all) ,570 Life sciences ,biology ,Radiology ,Dog Disease ,Case-Control Studie ,business ,Myelography - Abstract
Objective—To determine the incidence of adverse events within 24 hours after contrast-enhanced ultrasonography (CEUS) in dogs and cats and compare the risk of death within 24 hours after imaging for animals that underwent ultrasonography with and without injection of a contrast agent. Design—Retrospective case-control study. Animals—750 animals (411 case dogs, 238 control dogs, 77 case cats, and 24 control cats). Procedures—At 11 institutions, medical records were reviewed of dogs and cats that had CEUS performed (cases) as were medical records of dogs and cats with clinical signs similar to those of case animals that had ultrasonography performed without injection of a contrast agent (controls). Information regarding signalment; preexisting disease; type, dose, and administration route of contrast agent used; immediate (within 1 hour after CEUS) and delayed (> 1 and ≤ 24 hours after CEUS) adverse events; and occurrence and cause of death (when available) was extracted from each medical record. Risk of death within 24 hours after ultrasonography was compared between case and control animals. Results—Of the 411 case dogs, 3 had immediate adverse events (vomiting or syncope) and 1 had a delayed adverse event (vomiting). No adverse events were recorded for case cats. Twenty-three of 357 (6.4%) clinically ill case animals and 14 of 262 (5.3%) clinically ill control animals died within 24 hours after ultrasonography; risk of death did not differ between cases and controls. Conclusions and Clinical Relevance—Results indicated that CEUS was safe in dogs and cats.
- Published
- 2013