1. Long-term outcomes after aortic root repair using selective sinus replacement
- Author
-
Vadim Irimie, Lukas Lehmkuhl, Akram Ahmidou, Gjoko Kucinoski, Anno Diegeler, Atanas Jankulowski, Alaa Atieh, Paul P. Urbanski, Xiaochun Zhan, and Tarvo Thamm
- Subjects
Pulmonary and Respiratory Medicine ,Aortic valve ,medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Hazard ratio ,medicine.disease ,Surgery ,Dissection ,medicine.anatomical_structure ,Bicuspid aortic valve ,Aneurysm ,cardiovascular system ,medicine ,Pericardium ,Cardiac skeleton ,Cardiology and Cardiovascular Medicine ,business ,Computed tomography angiography - Abstract
Objectives The study aim was to evaluate long-term results after anatomic restoration of the aortic root. Methods During an 18-year period, a total of 669 patients underwent valve-sparing root repair (aneurysm 554, dissection 115) using selective sinus replacement. None/trivial, mild, moderate, and severe (grades 3+ and 4+) insufficiency were present in 57, 146, 204, and 262 patients, respectively. Results The anatomic repair was adjusted to the existing aortic annulus diameter, which was 27.0 ± 3.0 mm on average. Replacement of 1, 2, or 3 sinuses of Valsalva was performed in 209, 234, and 226 patients, respectively. Altogether, 454 additional procedures on the cusps were performed, mostly as cusp patch plasty with pericardium (210). Thirty-day mortality was 0.6%. The mean follow-up duration was 7.1 ± 4.1 years (range, 0.01-19.1 years). The estimated freedom from relevant aortic insufficiency grade 3+ or greater (15 events) was 98% ± 1%, 97% ± 1%, and 94% ± 3% at 5, 10, and 15 years, respectively. On echocardiogram, no patient revealed a considerable change of the form or size of the repaired root, which was confirmed radiologically in 160 patients who received computed tomography angiography for any reason. Multivariate logistic regression analysis identified cusp prolapse/pseudo-prolapse as the only independent risk factor for the development of recurrent insufficiency grade 2+ or greater (41 occurrences), with a hazard ratio of 3.258 (95% confidence interval, 1.658-6.403; P = .001). An association between aortic annulus size and functional results could not be demonstrated. Conclusions Patient-tailored root repair using isolated sinus replacement offers excellent functional long-term results regardless of underlying root pathology or annulus size. Aortic cusp pathology was decisive for long-term valve function.
- Published
- 2021