64 results on '"Marta Arias"'
Search Results
2. Comparison of efficacy and safety of the new generation helixone dialyzers
- Author
-
Francisco Maduell, José Jesús Broseta, Diana Rodríguez-Espinosa, Lida María Rodas, Miquel Gómez, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Maria del Carmen Salgado, Nayra Rico, and Rosa Ramos
- Subjects
Eficacia ,Helixona ,Hemodiafiltración ,Reacciones adversas ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. Material and methods: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. Results: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34 L. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of β2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5 g lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. Conclusion: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation. Resumen: Introducción: Recientemente se han desarrollado dializadores de helixona de nueva generación como parte del esfuerzo continuo para mejorar la biocompatibilidad del dializador y evitar reacciones adversas a los dializadores sintéticos. Este estudio tuvo como objetivo evaluar el rendimiento y la pérdida de albúmina de esta nueva serie de dializadores en hemodiafiltración y compararla con dializadores de helixona de la generación anterior. Material y métodos: Se realizó un estudio prospectivo en 19 pacientes. Cada paciente recibió ocho sesiones de diálisis con los mismos parámetros de diálisis de rutina; sólo varió el dializador: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax y FX CorAL 800. Los índices de reducción (RR) de urea, creatinina, ß2-microglobulina, mioglobina, cadenas ligeras kappa (κFLC), prolactina, α1-microglobulina, α1-glicoproteína ácida, cadenas ligeras lambda (λFLC) y albúmina se compararon intraindividualmente. También se midió la pérdida de albúmina del dializado. Resultados: Todos los tratamientos fueron bien tolerados. La media de líquido de reposición osciló entre 31 y 34 litros. La comparación de los tratamientos de diálisis no mostró diferencias entre moléculas pequeñas e incluso del tamaño de las β2-microglobulinas. Se encontraron pocas diferencias entre los RR de mioglobina, κFLC, prolactina, α1-microglobulina y λFLC. Las pérdidas de albúmina en el dializado fueron similares, con menos de 2,5 gramos por sesión. El dializador FX80 CorDiax mostró puntuaciones de eliminación global ligeramente más altas que el resto de los evaluados, a excepción del FX CorAL 800. Conclusión: La nueva generación de dializadores de helixona, actualizado para minimizar el riesgo de reacciones adversas, ha mantenido la eficacia y la pérdida de albúmina conseguidas por la generación de helixona previa.
- Published
- 2024
- Full Text
- View/download PDF
3. Correlation of plasmatic sodium determined by the laboratory and that determined by the dialysis machine
- Author
-
Joaquim Casals, José Jesús Broseta, Rosa María Fernández, Diana Rodriguez-Espinosa, Jimena del Risco, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Naira Rico, and Francisco Maduell
- Subjects
Dialisancia iónica ,Hemodiálisis ,individualización ,Sodio plasmático ,Módulo de sodio ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Changes in plasma sodium concentration (pNa, expressed in mEq/L) are common in hemodialysis (HD) patients. Hemodialysis monitors can estimate pNa by using an internal algorithm based on ion dialysance measurements. The present study studies the accuracy of the correlation between the pNa estimated by the dialysis monitor and that measured by the biochemistry laboratory at our center. Material and methods: A single-centre prospective observational study in patients on a chronic HD program with the 6008 CAREsystem monitor and standard sodium (138 mmol/L) and bicarbonate (32 mmol/L) prescriptions. Venous blood samples were drawn from each patient before and after each HD session to ensure inter- and intra-individual validity. The pNa was measured in the biochemistry laboratory using indirect potentiometry and simultaneously the estimated pNa by the HD monitor was recorded at the beginning and at the end of the HD session. For statistical analysis, a scatterplot was made, and Spearman’s correlation quotient was calculated. In addition, the differences between both methods were represented as Bland-Altman diagrams. Results: The pre-dialysis pNa measured in the laboratory was 137.49 ± 3.3, and that of the monitor, 137.96 ± 2.91, with a correlation with R2 value of 0.683 (p
- Published
- 2024
- Full Text
- View/download PDF
4. Correlación entre el sodio plasmático determinado por el laboratorio y el determinado por el monitor de hemodiálisis
- Author
-
Joaquim Casals, José Jesús Broseta, Rosa María Fernández, Diana Rodriguez-Espinosa, Jimena del Risco, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Naira Rico, and Francisco Maduell
- Subjects
Ionic dialysance ,Hemodialysis ,Individualization ,Plasmatic sodium ,Sodium module ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Las alteraciones de la concentración plasmática de sodio (Nap, expresado en mEq/l) son frecuentes en los pacientes en hemodiálisis (HD). Los monitores de HD tienen la capacidad de estimar la Nap mediante un algoritmo interno a partir de las medidas de la dialisancia iónica. En el presente trabajo se estudia la correlación entre la Nap estimada por el monitor de diálisis y la medida en el laboratorio de bioquímica de nuestro centro. Material y métodos: Estudio observacional prospectivo y unicéntrico en los pacientes en programa crónico de HD con el monitor 6008 CAREsystem y prescripción estándar de sodio (138 mEq/l) y bicarbonato (32 mmol/l). De cada paciente se extrajeron muestras de sangre venosa antes y después de la sesión para asegurar validez inter e intraindividual. Se analizó la Nap en el laboratorio mediante potenciometría indirecta y simultáneamente se registraba la estimada por el monitor de HD al inicio y al terminar la sesión. Para el análisis estadístico se realizó un diagrama de dispersión y se calculó el cociente de correlación de Spearman. Además, se representaron las diferencias entre métodos mediante diagramas de Bland-Altman. Resultados: La Nap prediálisis medida en el laboratorio fue de 137,49 ± 3,3, y la del monitor 137,96 ± 2,91, con una correlación con valor de R2 de 0,683 (p
- Published
- 2024
- Full Text
- View/download PDF
5. Comparación de la eficacia y seguridad de la nueva generación dializadores de helixona
- Author
-
Francisco Maduell, José Jesús Broseta, Diana Rodríguez-Espinosa, Lida María Rodas, Miquel Gómez, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Maria del Carmen Salgado, Nayra Rico, and Rosa Ramos
- Subjects
Dialyzer performance ,Helixone ,Hemodiafiltration ,Adverse reactions ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Recientemente se han desarrollado dializadores de helixona de nueva generación como parte del esfuerzo continuo para mejorar la biocompatibilidad del dializador y evitar reacciones adversas a los dializadores sintéticos. Este estudio tuvo como objetivo evaluar el rendimiento y la pérdida de albúmina de esta nueva serie de dializadores en hemodiafiltración y compararla con dializadores de helixona de la generación anterior. Material y métodos: Se realizó un estudio prospectivo en 19 pacientes. Cada paciente recibió ocho sesiones de diálisis con los mismos parámetros de diálisis de rutina; solo varió el dializador: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax y FX CorAL 800. Los índices de reducción (RR) de urea, creatinina, β2-microglobulina, mioglobina, cadenas ligeras kappa (κFLC), prolactina, α1-microglobulina, α1-glicoproteína ácida, cadenas ligeras lambda (λFLC) y albúmina se compararon intraindividualmente. También se midió la pérdida de albúmina del dializado. Resultados: Todos los tratamientos fueron bien tolerados. La media de líquido de reposición osciló entre 31 y 34 litros. La comparación de los tratamientos de diálisis no mostró diferencias entre moléculas pequeñas e incluso del tamaño de las β2-microglobulinas. Se encontraron pocas diferencias entre los RR de mioglobina, κFLC, prolactina, α1-microglobulina y λFLC. Las pérdidas de albúmina en el dializado fueron similares, con menos de 2,5 gramos por sesión. El dializador FX80 CorDiax mostró puntuaciones de eliminación global ligeramente más altas que el resto de los evaluados, a excepción del FX CorAL 800. Conclusión: La nueva generación de dializadores de helixona, actualizada para minimizar el riesgo de reacciones adversas, ha mantenido la eficacia y la pérdida de albúmina conseguidas por la generación de helixona previa. Abstract: Introduction: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. Material and methods: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, β2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. Results: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34 litres. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of β2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5 grams lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. Conclusion: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation.
- Published
- 2024
- Full Text
- View/download PDF
6. Role of crystal orientation in attosecond photoinjection dynamics of germanium
- Author
-
Nicola Di Palo, Lyudmyla Adamska, Simone Bonetti, Giacomo Inzani, Matteo Talarico, Marta Arias Velasco, Gian Luca Dolso, Rocío Borrego-Varillas, Mauro Nisoli, Stefano Pittalis, Carlo Andrea Rozzi, and Matteo Lucchini
- Subjects
Crystallography ,QD901-999 - Abstract
Understanding photoinjection in semiconductors—a fundamental physical process—represents the first step toward devising new opto-electronic devices, capable of operating on unprecedented time scales. Fostered by the development of few-femtosecond, intense infrared pulses, and attosecond spectroscopy techniques, ultrafast charge injection in solids has been the subject of intense theoretical and experimental investigation. Recent results have shown that while under certain conditions photoinjection can be ascribed to a single, well-defined phenomenon, in a realistic multi-band semiconductor like Ge, several competing mechanisms determine the sub-cycle interaction of an intense light field with the atomic and electronic structure of matter. In this latter case, it is yet unclear how the complex balance between the different physical mechanisms is altered by the chosen interaction geometry, dictated by the relative orientation between the crystal lattice and the laser electric field direction. In this work, we investigate ultrafast photoinjection in a Ge monocrystalline sample with attosecond temporal resolution under two distinct orientations. Our combined theoretical and experimental effort suggests that the physical mechanisms determining carrier excitation in Ge are largely robust against crystal rotation. Nevertheless, the different alignment between the laser field and the crystal unit cell causes non-negligible changes in the momentum distribution of the excited carriers and their injection yield. Further experiments are needed to clarify whether the crystal orientation can be used to tune the photoinjection of carriers in a semiconductor at these extreme time scales.
- Published
- 2024
- Full Text
- View/download PDF
7. Electrophysiological findings in long-term type 1 diabetes patients without diabetic retinopathy using different ERG recording systems
- Author
-
Marta Arias-Alvarez, Cristina Tomas-Grasa, Maria Sopeña-Pinilla, Elvira Orduna-Hospital, Guisela Fernandez-Espinosa, Sofia Bielsa-Alonso, Javier Acha-Perez, Diego Rodriguez-Mena, and Isabel Pinilla
- Subjects
Medicine ,Science - Abstract
Abstract To assess full-field electroretinogram findings in long-term type 1 diabetes patients without diabetic retinopathy. Prospective study including 46 eyes of 23 patients with type 1 diabetes and 46 age-matched healthy eyes evaluated by the RETI-port/scan21 and the portable system RETeval following ISCEV guidelines. The average duration of diabetes was 28.88 ± 8.04 years. In scotopic conditions, using the RETI-port/scan21, diabetic patients showed an increase in b-wave implicit time (IT) (p = 0.017) with the lowest stimuli; a diminished b-wave amplitude (p = 0.005) in the mixed response, an increased IT (p = 0.004) with the high-intensity stimuli and an OP2 increased IT (p = 0.008) and decreased amplitude (p = 0.002). Under photopic conditions, b-wave amplitude was lower (p
- Published
- 2024
- Full Text
- View/download PDF
8. Tracking Macular Sensitivity and Inner Retinal Thickness in Long-Term Type 1 Diabetes: A Five-Year Prospective Examination in Patients without Diabetic Retinopathy
- Author
-
Guisela Fernández-Espinosa, Elvira Orduna-Hospital, María Sopeña-Pinilla, Marta Arias-Álvarez, Ana Boned-Murillo, María Dolores Díaz-Barreda, Ana Sánchez-Cano, and Isabel Pinilla
- Subjects
type 1 diabetes mellitus ,microperimetry ,spectral domain optical coherence tomography (SD-OCT) ,retinal thickness ,macular sensitivity ,Science - Abstract
The aim of the study is to compare macular sensitivity and retinal thickness in patients with long-term type 1 diabetes mellitus (DM1) without diabetic retinopathy (DR) after 5 years of follow-up. Thirty-two eyes from 32 long-term DM1 patients without DR were included. All participants underwent a complete ophthalmological examination, including microperimetry and spectral domain optical coherence tomography (SD-OCT). The data were compared with results from 5 years prior. The mean age of the DM1 patients was 43.19 ± 10.17 years, with a mean disease duration of 29.84 ± 8.98 years and good glycemic control. In 2023, patients exhibited a significantly worse best corrected visual acuity (BCVA) compared to 2018 (p < 0.001). DM1 patients did not show statistically significant changes in macular sensitivity over the 5-year follow-up period. Macular integrity showed significant differences between the two time points (p = 0.045). Retinal thickness showed significant differences, particularly in inner retinal layers (IRL) across most of the ETDRS areas. Long-term DM1 patients without DR lesions showed worsened macular integrity and a lower BCVA in 2023. Additionally, they displayed significant alterations in retinal thicknesses, especially in the IRL, between 2018 and 2023. These findings suggest that even in the absence of visible DR, long-term DM1 patients may experience subclinical retinal changes and functional deterioration over time, highlighting the importance of regular monitoring for the early detection and management of potential complications.
- Published
- 2024
- Full Text
- View/download PDF
9. Conductivity variations and changes in serum sodium concentration during dialysis related to monitor switching
- Author
-
Francisco Maduell, José Jesús Broseta, Joaquim Casals, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, and Néstor Fontseré
- Subjects
Hemodiálisis ,Sodio ,Conductividad ,Biosensores ,Prescripción de diálisis ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusion: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors. Resumen: Introducción: El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos: Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió 2 sesiones de diálisis en la que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados: El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138.14 mmol/L con 5008 vs 138.81 mmol/L con 6008) y final (139.58 mmol/L vs 140.97 mmol/L), así como en la conductividad real obtenida (13,97 vs 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión: El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores.
- Published
- 2023
- Full Text
- View/download PDF
10. Variaciones de la conductividad y cambios en el sodio plasmático durante hemodiálisis relacionado con el cambio de monitor
- Author
-
Francisco Maduell, José Jesús Broseta, Joaquim Casals, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, and Néstor Fontseré
- Subjects
Hemodialysis ,Sodium ,Conductivity ,Biosensors ,Dialysis prescription ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos: Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió dos sesiones de diálisis en las que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados: El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138,14 mmol/L con 5008 vs. 138,81 mmol/L con 6008) y final (139,58 mmol/L vs. 140,97 mmol/L), así como en la conductividad real obtenida (13,97 vs. 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión: El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores. Abstract: Introduction: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusión: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors.
- Published
- 2023
- Full Text
- View/download PDF
11. Retinochoroidal Vascular Changes in Long-Term Type 1 Diabetic Patients Assessed by Optic Coherence Tomography Angiography
- Author
-
Maria Sopeña-Pinilla, Elvira Orduna-Hospital, Maria D. Diaz-Barreda, Ana Boned-Murillo, Guisela Fernandez-Espinosa, Marta Arias-Alvarez, Javier Acha-Perez, Ana Sanchez-Cano, and Isabel Pinilla
- Subjects
diabetes mellitus ,diabetic retinopathy ,foveal avascular zone ,retinal vascularization ,optical coherence tomography angiography ,Biology (General) ,QH301-705.5 - Abstract
To study retinal and choriocapillaris (CC) alterations using optical coherence tomography angiography (OCTA) in long-term type 1 diabetic (DM1) patients without diabetic retinopathy (DR). Seventy-eight eyes from 78 well-controlled DM1 patients diagnosed at least 15 years prior and 130 eyes of 130 healthy subjects were included in a cross-sectional descriptive study. Six eyes were excluded from the DM1 group. OCTA with Deep Range Imaging (DRI)-Triton swept source (SS)-OCT was performed. Statistically significant differences were found in all areas of the superficial capillary plexus (SCP), with lower values in DM1 patients. Differences were noted in all quadrants of the deep capillary plexus (DCP) except for the central area. Significant changes in CC blood flow were only found in the center. The foveal avascular zone (FAZ) area and diameters in the SCP were significantly different, while the DCP FAZ area was similar in both groups. Disease duration and microalbuminuria correlated negatively with some SCP areas and positively with FAZ values. Anatomical evaluation revealed microaneurysms in both plexuses, FAZ modifications, and areas lacking blood perfusion. Long-term type 1 diabetic patients without DR display microvascular abnormalities affecting retinal and CC blood perfusion, along with anatomical changes in retinal blood vessels.
- Published
- 2024
- Full Text
- View/download PDF
12. Metabolomics and Biochemical Benefits of Multivitamin and Multimineral Supplementation in Healthy Individuals: A Pilot Study
- Author
-
María C. Sánchez, Ana Herráiz, María J. Ciudad, Marta Arias, Raquel Alonso, Carmen Doblas, Arancha Llama-Palacios, and Luis Collado
- Subjects
nutritional supplement ,multivitamin complex ,multimineral complex ,natural origin vitamins and minerals ,homocysteine ,iron ,Chemical technology ,TP1-1185 - Abstract
Scientific evidence regarding the effectiveness of vitamin and mineral supplements in healthy individuals remains scarce. In a randomized, double-blind study, 30 healthy individuals were assigned to receive a single daily dose of multivitamin and multimineral supplementation or a double daily dose for 30 days. Before and after the intake, an untargeted metabolomics assay for serum metabolites was conducted by hydrophilic interaction liquid chromatography–mass spectrometry, and clinical assessments of peripheral blood samples were performed. A paired t-test for metabolic analysis, adjusted using the false discovery rate (FDR) and p-value correction method (rate of change > 2 and FDR < 0.05), the Shapiro–Wilk test, Student’s t-test, and the Mann–Whitney U test were applied depending on the variable, with a 5% significance level. An impact on oxidative stress was observed, with a significant reduction in homocysteine levels and an increment of pyridoxic acid (vitamin B6). The effect on energy metabolism was shown by a significant increase in diverse metabolites, such as linoleoylcarnitine. Serum iron and calcium levels were also impacted. Overall, we observed a nutritional balance compatible with a good state of health. In conclusion, beneficial effects on adult health were demonstrated in relation to oxidative stress, energy metabolism, and nutritional balance.
- Published
- 2024
- Full Text
- View/download PDF
13. Retinal Function in Long-Term Type 1 Diabetes without Retinopathy: Insights from Pattern Electroretinogram and Pattern Visual Evoked Potentials Assessments
- Author
-
Marta Arias-Alvarez, Maria Sopeña-Pinilla, Guisela Fernandez-Espinosa, Elvira Orduna-Hospital, Ines Vicente-Garza, Anna Bonet-Rodriguez, Javier Acha-Perez, Diego Rodriguez-Mena, and Isabel Pinilla
- Subjects
type 1 diabetes ,diabetic retinopathy ,pattern electroretinogram ,pattern visual evoked potentials ,Medicine (General) ,R5-920 - Abstract
Background: To evaluate changes in pattern electroretinogram (pERG) and pattern visual evoked potentials (pVEP) in patients with long-lasting type 1 diabetes without diabetic retinopathy (DR). Methods: Prospective study involving 92 eyes divided into two groups. The diabetic group included 46 eyes of 23 patients with type 1 diabetes (T1DM); the control group included 23 age-matched healthy subjects. pERG and pVEP were assessed using the RETI-port/scan21 recording software (version 1021.3.0.0). Results: Mean age was 48 ± 9.77 years for the diabetic group and 51.7 ± 4.75 years for the control group. The mean duration of diabetes was 28.88 ± 8.04 years. The mean HbA1c value was 7.29 ± 0.89%. There were no differences in the age or sex distribution. Regarding the pERG, T1DM patients exhibited a significant decrease in the amplitude of the P50 and N95 waves compared to the control group (p = 0.018 and p = 0.035, respectively), with no differences in the peak time of each component. pVEP showed no significant changes in either peak time or amplitude of the different components. Conclusions: Long-term T1DM patients without DR showed changes in the amplitude of pERG waves with preserved peak times. We did not observe modifications in pVEP. pERG may serve as a subclinical marker of ganglion cell damage in long-term T1DM patients.
- Published
- 2024
- Full Text
- View/download PDF
14. Valoración de la fragilidad en un centro de diálisis. ¿son más frágiles los pacientes con diabetes?
- Author
-
Sonia Guerrero-Carreño, Eva Elías-Sanz, Miquel Gomez-Umbert, Marta Quintela-Martínez, Teresa Gabarró-Taulé, and Marta Arias-Guillén
- Subjects
diabetes mellitus ,insuficiencia renal crónica ,fragilidad ,hemodiálisis ,Nursing ,RT1-120 ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: El incremento en la inclusión de personas de edad avanzada a los programas de hemodiálisis se relaciona con un aumento de la prevalencia de fragilidad, considerada predictora de discapacidad y asociada a eventos adversos de salud. Dado su carácter reversible, es importante hacer un cribaje para mejorar la práctica clínica. Objetivo: Evaluar el grado de fragilidad y estado funcional del paciente en nuestra unidad de hemodiálisis y analizar las diferencias entre diabéticos y no diabéticos. Material y Método: Estudio observacional de corte transversal. La fragilidad se midió utilizando el fenotipo de Fried y la valoración funcional mediante las escalas Barthel, Lawton, Downton y la Short Physical Performance Battery. Se evaluó comorbilidad y riesgo de caídas con las escalas Charlson y Downton respectivamente. Se comparó entre grupos de diabéticos y no diabéticos y se analizó la relación entre la fragilidad y la edad, dependencia, comorbilidad y riesgo de caídas. Resultados: Se incluyeron 128 pacientes. El 45% tenían Diabetes. Los pacientes con diabetes tenían una edad media mayor que los no diabéticos (74,2±11 vs 67,8±15 años) y mayor comorbilidad (Charlson 8,2±2,2 vs 5,8±2,4). El 25% de los pacientes presentaron fragilidad, observando una tendencia que sugirió mayor fragilidad, peor capacidad funcional y mayor grado de dependencia en los pacientes diabéticos, aunque de forma no significativa. Conclusiones: Una cuarta parte de la población estudiada presenta fragilidad, con una tendencia más acusada a padecerla los pacientes diabéticos, que podría estar relacionada con mayor edad, mayor comorbilidad y menor capacidad funcional que los no diabéticos.
- Published
- 2023
- Full Text
- View/download PDF
15. Efficacy of systematic catheter locks solution of taurolidine/heparin versus taurolidine/urokinase in end-stage renal insufficiency stage 5D
- Author
-
Néstor Fontseré, Alex Soriano, Gaspar Mestres, Patricia Bermudez, Federico Zarco, Valentín Lozano, Lida Rodas, Jose Broseta, Marta Arias, and Francisco Maduell
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Published
- 2022
- Full Text
- View/download PDF
16. Eficacia de los sellados sistemáticos de catéter con taurolidina/heparina versus taurolidina/uroquinasa en pacientes con insuficiencia renal crónica estadio 5D
- Author
-
Néstor Fontseré, Alex Soriano, Gaspar Mestres, Patricia Bermudez, Federico Zarco, Valentín Lozano, Lida Rodas, Jose Broseta, Marta Arias, and Francisco Maduell
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Published
- 2022
- Full Text
- View/download PDF
17. Guía de unidades de hemodiálisis 2020
- Author
-
Guillermo Alcalde-Bezhold, Roberto Alcázar-Arroyo, Manuel Angoso-de-Guzmán, María Dolores Arenas, Marta Arias-Guillén, Patricia Arribas-Cobo, Juan Manuel Díaz-Gómez, Rafael García-Maset, Emilio González-Parra, Domingo Hernández-Marrero, José Antonio Herrero-Calvo, Francisco Maduell, Pablo Molina, Manuel Molina-Núñez, Alfonso Otero-González, Julio Pascual, Mónica Pereira-García, Rafael Pérez-García, María Dolores del Pino y Pino, Mario Prieto-Velasco, Juan Francisco Pulido Pulido, José Emilio Sánchez-Álvarez, Rosa Sánchez-Hernández, Patricia de Sequera-Ortiz, Rafael Pérez García, María Dolores del Pino Pino, Carlos Quereda Rodríguez-Navarro, Guillermo Alcalde Bezhold, Roberto Alcázar Arroyo, Manuel Angoso de Guzmán, Mª Dolores Del Pino y Pino, Domingo Hernández Marrero, Alfonso Otero González, Dolores Arenas Jiménez, Ángel Martín de Francisco Hernández, Alejandro Martín Malo, Rosa Inés Muñoz González, Rafael Díaz-Tejeiro Izquierdo, Milagros Fernández Lucas, Eduardo Gutiérrez Martínez, Raquel Ojeda López, Mario Prieto Velasco, Patrocinio Rodríguez Benítez, Alfredo José Sáenz Santolaya, María Fernanda Slon Roblero, José Luis Teruel Briones, and Fernando Tornero Molina
- Subjects
Clinical guidelines ,S.E.N. ,Hemodialysis ,Hemodialysis centers ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Presentamos una nueva edición de la Guía de Centros de Hemodiálisis. Se enmarca en el programa de actualización de las Guías Clínicas de la Sociedad Española de Nefrología. Es un documento de consenso en el que han colaborado nefrólogos con amplia experiencia en diálisis y expertos de la enfermería nefrológica. La Guía ha sido corregida por un grupo de evaluadores externos. Se ha informado y se ha tomado en consideración la opinión de los pacientes a través de la Asociación de Enfermos Renales (ALCER). Esta Guía incluye en sus diez capítulos aspectos arquitectónicos, logísticos y organizativos. Hace especial énfasis en las necesidades de recursos humanos y su cualificación. Revisa las modalidades actuales de hemodiálisis, su dosificación y adecuación y la monitorización y seguimiento intra e interdiálisis. La hemodiálisis es una de las formas de tratamiento renal sustitutivo, por lo que menciona la necesidad de la inclusión en lista de espera para trasplante y la relación con las unidades de diálisis peritoneal. La calidad de vida del paciente en hemodiálisis comprende la necesidad de relacionarse y viajar por lo que se revisa y estandariza la atención de los pacientes transeúntes. La gestión de calidad es una herramienta necesaria actualmente para lograr la mejora continua de cualquier procedimiento como la hemodiálisis. Esta Guía pretende ser una ayuda para el buen funcionamiento de las Unidades de Diálisis, para los responsables de las mismas, así como para los gestores sanitarios. Abstract: We present a new edition of the Hemodialysis Center Guide. It is part of the program of updating the Clinical Guides of the Spanish Society of Nephrology. It is a consensus document in which nephrologists with extensive experience in dialysis and experts in nephrological nursing have collaborated. The Guide has been corrected by a group of external evaluators. The opinion of the patients through the kidney diseases patient association (ALCER) has been reported and taken into consideration. This Guide includes in its ten chapters architectural, logistical and organizational aspects. It places special emphasis on human resources needs and their qualification. Review current hemodialysis modalities, dosage and adequacy, and intra and interdialysis monitoring. Hemodialysis is one of the forms of renal replacement therapy, so it mentions the need for transplant waiting list inclusion and the relationship with peritoneal dialysis units. The patient's quality of life on hemodialysis understands the need to relate and travel so care of transitory patients is reviewed and standardized. Quality management is a tool currently needed to achieve continuous improvement of any procedure such as hemodialysis. This Guide is intended to be an aid for the proper functioning of the Dialysis Units, for those responsible for them, as well as for health managers.
- Published
- 2021
- Full Text
- View/download PDF
18. Eficacia y seguridad de un programa de ejercicio físico intradiálisis
- Author
-
Anna Yuguero-Ortiz, Miquel Gomez, Marta Arias-Guillén, Raquel Ojeda, Néstor Fontseré, Lida Rodas, José Jesús Broseta, Manel Vera, Sonsoles Hernandez-Sanchez, and Francisco Maduell
- Subjects
Intradialytic physical exercise program ,Cardiopulmonary capacity ,Muscular strength ,Vascular refilling profile ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Los pacientes en hemodiálisis (HD) suelen tener una condición física mermada y elevado sedentarismo. La consolidación de programas de ejercicio físico en las unidades de diálisis está limitada por barreras como la seguridad inherente a estos programas y la falta de recursos. Objetivos: Evaluar la eficacia y seguridad en la implantación de un programa de ejercicio físico intradiálisis (EFI) sobre la condición física de los pacientes con un equipo multidisciplinar (fisioterapeuta y auxiliares de enfermería). Material y métodos: Estudio cuasiexperimental pre-post unicéntrico prospectivo de 6 meses en 34 pacientes. Intervención con EFI combinado 2 días a la semana, evaluándose de forma basal y final la capacidad cardiorrespiratoria (6MWT), fuerza muscular (HG, dinamometría de cuádriceps y 10STS), la composición corporal (bioimpedanciometría) y la capacidad coordinativa (Timed Up and Go test). La seguridad se valoró registrando las incidencias relacionadas con el acceso vascular, la estabilidad hemodinámica y el perfil de rellenado vascular (RBV) durante las sesiones. También se registró la adherencia al programa así como parámetros analíticos habituales. Resultados: La adherencia al programa de EFI fue elevada (70,8%). Se constató una mejora significativa de 47 m (p
- Published
- 2021
- Full Text
- View/download PDF
19. Impact and safety outcomes of an intradialytic physical exercise program
- Author
-
Anna Yuguero-Ortiz, Miquel Gomez, Marta Arias-Guillén, Raquel Ojeda, Néstor Fontseré, Lida Rodas, José Jesús Broseta, Manel Vera, Sonsoles Hernandez-Sanchez, and Francisco Maduell
- Subjects
Ejercicio físico intradiálisis ,Capacidad cardiorrespiratoria ,Fuerza muscular ,Rellenado vascular ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Patients undergoing hemodialysis (HD) are characterized by a poor physical condition and a substantial sedentary profile. The implementation of physical exercise programs in the hemodialysis units is usually limited by the inherent safeness and the lack of appropriate resources. Objectives: We aimed to evaluate the impact and safety outcomes of the implementation of an intradialytic physical exercise program (IPE) by a multidisciplinary team (physiotherapist and nursing assistant) in the physical condition of the patients. Material and methods: This six months single-centre and experimental pre-post prospective study was carried out in 34 patients. A two day-week combined IPE intervention was implemented. The cardiopulmonary capacity (6MWT), muscular strength (HG, leg dynamometry and 10STS), body composition (bioimpedance) and coordination capacity (Timed Up and Go test) was assessed at the beginning and at the end of the study. Safety was evaluated by means of the number of issues regarding the vascular access, the hemodynamic stability as well as the vascular refilling profile (RBV) in each session. The adhesion to the program was also registered. Additionally, analytical parameters were recorded. Results: The adhesion to an IPE program was high (70.8%). A significant improvement of the cardiopulmonary capacity (6MWT average increase 47 m; p
- Published
- 2021
- Full Text
- View/download PDF
20. Evaluation of the influence of the surface membrane and blood flow in medium «cut-off» (MCO) dialyzers
- Author
-
Francisco Maduell, Lida Rodas, José Jesús Broseta, Miquel Gómez, Enrique Montagud-Marrahi, Elena Guillén, Evelyn Hermida, Marc Xipell, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, and Nayra Rico
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Recently, a new class of dialyzers, medium cut-off membranes (MCO), designed to improve the permeability, which could provide an efficacy similar to hemodiafiltration, have been incorporated into our therapeutic possibilities. To increase the knowledge about its use, the objective of the study was to evaluate the effect of the surface and blood flow (Qb) on the depurative efficacy in the MCO membranes. Material and methods: We included 19 patients in the hemodialysis. Each patient received 6 sessions, in which the membrane surface was varied, 1.7 or 2.0 m2, and/or the Qb (300, 350, 400 or 450 mL/min). In each session, different solutes were determined at the beginning and end of dialysis. Results: The surface change of the dialyzer did not show significant differences in the removal of small or large molecules, without changes in albumin loss. The increase in Qb was accompanied by an increase in clearance of small molecules, without showing differences in the percentage reduction of β2-microglobulin, myoglobin, prolactin, α1-microglobulin and α1-acid glycoprotein, except for some comparison with Qb 450 mL/min. There were also no differences in the loss of albumin in the dialysis fluid, less than 2.5 grams in all situations. Conclusion: The increase of the surface area of 1.7–2.0 m2 in the MCO dialyzer has not meant a greater depurative effectiveness. In these dialyzers the increase of Qb does not seem to be as determinant as in hemodiafiltration except for the clearance of small molecules. Resumen: Introducción: Recientemente, se han incorporado en nuestras posibilidades terapéuticas, una nueva clase de dializadores, membranas de medio cut-off (MCO), diseñados para mejorar la permeabilidad y podrían alcanzar una eficacia similar a la hemodiafiltración. Para aumentar el conocimiento sobre su utilización, el objetivo del estudio fue valorar en las membranas de MCO el efecto de la superficie y del flujo sanguíneo (Qb) sobre la eficacia depurativa. Material y métodos: Se incluyeron 19 pacientes en programa de hemodiálisis. Cada paciente recibió 6 sesiones, en las que se varió la superficie de membrana, 1.7 o 2.0 m2, y el Qb (300, 350, 400 o 450 mL/min). En cada sesión se determinaron diferentes solutos al inicio y al final de diálisis. Resultados: El cambio de superficie del dializador no mostró diferencias significativas en la depuración de pequeñas o grandes moléculas, sin cambios en la pérdida de albúmina. El aumento del Qb se acompaño de un aumento de depuración de pequeñas moléculas, sin mostrar diferencias en el porcentaje de reducción de β2-microglobulina, mioglobina, prolactina, α1-microglobulina y α1-glicoproteína ácida, a excepción de alguna comparación con Qb 450 mL/min. Tampoco se observaron diferencias en la pérdida de albúmina en el líquido de diálisis, inferior a 2.5 gramos en todas las situaciones. Conclusión: El incremento de la superficie de 1.7 a 2.0 m2 en el dializador de MCO no ha significado una mayor eficacia depurativa. En estos dializadores el aumento del Qb no parece ser tan determinante como en la hemodiafiltración a excepción de la depuración de pequeñas moléculas. Keywords: Dialyzer, Efficacy, Hemodiafiltration, Medium cut-off, Palabras clave: Dializador, Eficacia, Hemodiafiltración, Medio cut-off
- Published
- 2019
- Full Text
- View/download PDF
21. Valoración de la influencia de la superficie de la membrana y el flujo sanguíneo en dializadores de medio cut-off
- Author
-
Francisco Maduell, Lida Rodas, José Jesús Broseta, Miquel Gómez, Enrique Montagud-Marrahi, Elena Guillén, Evelyn Hermida, Marc Xipell, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, and Nayra Rico
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Recientemente, se ha incorporado a nuestras posibilidades terapéuticas una nueva clase de dializadores, las membranas de medio cut-off (MCO), diseñadas para mejorar la permeabilidad y que podrían alcanzar una eficacia similar a la hemodiafiltración. Para aumentar el conocimiento sobre su uso, el objetivo del estudio fue valorar en las membranas de MCO el efecto de la superficie y del flujo sanguíneo (Qb) sobre la eficacia depurativa. Material y métodos: Se incluyó a 19 pacientes en programa de hemodiálisis. Cada paciente recibió 6 sesiones, en las que se varió la superficie de membrana, de 1,7 o 2,0 m2, y el Qb (300, 350, 400 o 450 mL/min). En cada sesión se determinaron diferentes solutos al inicio y al final de la diálisis. Resultados: El cambio de superficie del dializador no mostró diferencias significativas en la depuración de pequeñas o grandes moléculas, sin cambios en la pérdida de albúmina. El aumento del Qb se acompañó de un aumento de depuración de pequeñas moléculas, sin mostrar diferencias en el porcentaje de reducción de β2-microglobulina, mioglobina, prolactina, α1-microglobulina y α1-glicoproteína ácida, a excepción de alguna comparación con Qb 450 mL/min. Tampoco se observaron diferencias en la pérdida de albúmina en el líquido de diálisis, inferior a 2,5 g en todas las situaciones. Conclusión: El incremento de la superficie de 1,7 a 2,0 m2 en el dializador de MCO no ha significado una mayor eficacia depurativa. En estos dializadores el aumento del Qb no parece ser tan determinante como en la hemodiafiltración, a excepción de la depuración de pequeñas moléculas. Abstract: Introduction: Recently, a new class of dialyzers, medium cut-off membranes (MCO), designed to improve the permeability, which could provide an efficacy similar to hemodiafiltration, have been incorporated into our therapeutic possibilities. To increase the knowledge about its use, the objective of the study was to evaluate the effect of the surface and blood flow (Qb) on the depurative efficacy in the MCO membranes. Material and methods: We included 19 patients in the hemodialysis. Each patient received 6 sessions, in which the membrane surface was varied, from 1.7 to 2.0 m2, and/or the Qb (300, 350, 400 or 450 mL/min). In each session, different solutes were determined at the beginning and end of dialysis. Results: The surface change of the dialyzer did not show significant differences in the removal of small or large molecules, without changes in albumin loss. The increase in Qb was accompanied by an increase in clearance of small molecules, without showing differences in the percentage reduction of β2-microglobulin, myoglobin, prolactin, α1-microglobulin and α1-acid glycoprotein, except for some comparison with Qb 450 mL/min. There were also no differences in the loss of albumin in the dialysis fluid, less than 2.5 g in all situations. Conclusion: The increase of the surface area from 1.7 to 2.0 m2 in the MCO dialyzer has not meant a greater depurative effectiveness. In these dialyzers the increase of Qb does not seem to be as determinant as in hemodiafiltration except for the clearance of small molecules. Palabras clave: Dializador, Eficacia, Hemodiafiltración, Medio cut-off, Keywords: Dialyzer, Efficacy, Hemodiafiltration, Medium cut-off
- Published
- 2019
- Full Text
- View/download PDF
22. A new generation of cellulose triacetate suitable for online haemodiafiltration
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Lida Rodas, Miquel Gómez, Karen P. Huablocho, Fanny Esquivel, Paola D. Mori, Valentina Hoffmann, Jessica Ugalde, and Nayra Rico
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Background: Online haemodiafiltration (OL-HDF) is currently the most effective dialysis technique that also improves survival. To date, high permeability membranes with low albumin loss, such as polysulfone, polyamide and polyacrylonitrile membranes have been the most widely used. However, the initially restricted use of cellulose triacetate (CTA) membranes in OL-HDF has expanded. The aim of the study was to ascertain whether the latest generation asymmetric CTA membranes are more effective in obtaining high convective transport. Patients and methods: A total of 16 patients (10 males and 6 females) undergoing OL-HDF were studied. Each patient underwent 4 different sessions, with haemodialysis or OL-HDF, and/or with CTA or asymmetric CTA 1.9 m2 membranes. Each session was assigned in a randomised order. Serum levels of urea, creatinine, β2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein and albumin where measured at the beginning and end of each session to obtain the reduction rate. The loss of solutes and albumin was quantified from the dialysate. Results: A significantly greater replacement volume in OL-HDF (32.1 ± 3.1 vs. 19.7 ± 4.5 l, pÂ
- Published
- 2018
- Full Text
- View/download PDF
23. Una nueva generación de triacetato de celulosa adecuado para hemodiafiltración on-line
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Lida Rodas, Miquel Gómez, Karen P. Huablocho, Fanny Esquivel, Paola D. Mori, Valentina Hoffmann, Jessica Ugalde, and Nayra Rico
- Subjects
Biocompatibilidad ,Hemodiafiltración on-line ,Triacetato de celulosa ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Antecedentes: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica de hemodiálisis (HD) más efectiva y aumenta la supervivencia. Hasta el momento presente las membranas de alta permeabilidad con baja pérdida de albúmina como las de polisulfona, poliamida y poliacrilonitrilo son las más utilizadas. Las membranas de triacetato de celulosa (TAC), limitadas inicialmente para su uso en HDF-OL, han evolucionado. El objetivo del estudio fue determinar si las membranas de nueva generación de TAC asimétrico (TACA) son más adecuadas para realizar alto transporte convectivo. Pacientes y métodos: Se estudiaron 16 pacientes, 10 hombres y 6 mujeres, en programa de HDF-OL. A cada paciente se le realizaron 4 sesiones diferentes, con HD o HDF-OL, o con filtros de TAC o TACA de 1,9 m2, aleatorizando el orden. En cada sesión se determinaron concentración de urea, creatinina, β2-microglobulina, mioglobina, prolactina, α1-microglobulina, α1-glicoproteína ácida y albúmina en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción. Así mismo, se cuantificó la pérdida de solutos y albúmina en el líquido de diálisis. Resultados: Con las membranas de TACA se consiguió un volumen de sustitución en HDF-OL significativamente superior a las membranas de TAC clásicas (32,1 ± 3,1 vs. 19,7 ± 4,5 L; p
- Published
- 2018
- Full Text
- View/download PDF
24. Evaluation of the dialyzer inner diameter in online haemodiafiltration
- Author
-
Francisco Maduell, Raquel Ojeda, Lara Belmar, Paula Munguía, Cristina Sango, Ana Isabel Martinez-Díaz, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Miquel Gómez, Lida Rodas, and Nayra Rico
- Subjects
Dialyzer ,Inner diameter ,Online haemodiafiltration ,Convective volume ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Online haemodiafiltration (OL-HDF) has been associated with increased survival. To date, the influence of the inner diameter of the hollow fibers of the dialyzer on convective volume has not been well established. The objective of the study was to evaluate the effect of increasing the inner diameter of the dialyzer on the convective volume and removal capacity. Material and methods: We included 16 patients in postdilutional OL-HDF. Each patient was analyzed in 4 sessions in which the inner diameter varied; 185 μm (FX60 Cordiax and FX80 Cordiax) vs. 210 μm (FX600 Cordiax and FX800 Cordiax). Different solutes were measured at the beginning and end of each dialysis session. Results: No differences in the convective volume were found with an increased inner diameter: 32.3 ± 3.1 vs. 31.8 ± 3.6 L/session (FX60 vs. FX600) and 33.7 ± 4.3 vs. 33.5 ± 3.8 L/session (FX80 vs. FX800). The reduction ratios also did not differ: urea 83.7 ± 4.5 vs. 84.1 ± 3.4 for FX60 and FX600, and 82.7 ± 4.1 vs. 83.6 ± 3.8 for FX80 vs. FX800; creatinine similar 78.2 ± 5.6 vs. 77.8 ± 4.6 and 77.1 ± 5.4 vs. 78.1 ± 4.9; β2-microglobulin 82.2 ± 4.3 vs. 82.9 ± 4.2, and 82.9 ± 4.7 vs. 84.0 ± 3.8; myoglobin 71.0 ± 10 vs. 70.2 ± 9 and 72.8 ± 11 vs. 75.0 ± 10; prolactin 70.4 ± 9 vs. 68.1 ± 9, and 72.2 ± 10 vs. 73.4 ± 8.2; and α1-microglobulin 22.9 ± 10 vs. 21.6 ± 10, and 26.5 ± 12 vs. 28.8 ± 11, respectively. Conclusion: The increase in the inner diameter of the hollow fibers did not result in improved convective volume and removal capacity.
- Published
- 2018
- Full Text
- View/download PDF
25. Valoración del diámetro interno del dializador en hemodiafiltración on-line
- Author
-
Francisco Maduell, Raquel Ojeda, Lara Belmar, Paula Munguía, Cristina Sango, Ana Isabel Martinez-Díaz, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Miquel Gómez, Lida Rodas, and Nayra Rico
- Subjects
Dializador ,Diámetro interno ,Hemodiafiltración on-line ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: Se ha asociado la hemodiafiltración on-line (HDF-OL) a un aumento de la supervivencia. Hasta el momento no está bien establecida la influencia del diámetro interno de las fibras capilares del dializador sobre la capacidad convectiva. El objetivo del estudio fue valorar el efecto del aumento del diámetro interno del dializador sobre el volumen convectivo y la capacidad depurativa. Material y métodos: Se incluyeron 16 pacientes en HDF-OL posdilucional con reposición automática. Cada paciente recibió 4 sesiones, en las que se varió el diámetro interno, 185 μm (FX60 Cordiax y FX80 Cordiax) versus 210 μm (FX600 Cordiax y FX800 Cordiax). En cada sesión se determinaron diferentes solutos al inicio y al final de la diálisis. Resultados: El incremento de diámetro interno entre FX60 vs. FX600 y FX80 vs. FX800 no reflejó diferencias en el volumen convectivo: 32,3 ± 3,1 vs. 31,8 ± 3,6 y 33,7 ± 4,3 vs. 33,5 ± 3,8 L/sesión, respectivamente. Los porcentajes de reducción tampoco mostraron diferencias: urea 83,7 ± 4,5 vs. 84,1 ± 3,4 para FX60 y FX600 y 82,7 ± 4,1 vs. 83,6 ± 3,8 para FX80 vs. FX800; creatinina similar 78,2 ± 5,6 vs. 77,8 ± 4,6 y 77,1 ± 5,4 vs. 78,1 ± 4,9; β2-microglobulina 82,2 ± 4,3 vs. 82,9 ± 4,2 y 82,9 ± 4,7 vs. 84,0 ± 3,8; mioglobina 71,0 ± 10, vs. 70,2 ± 9 y 72,8 ± 11 vs. 75,0 ± 10; prolactina 70,4 ± 9 vs. 68,1 ± 9 y 72,2 ± 10 vs. 73,4 ± 8,2; y α1-microglobulina 22,9 ± 10 vs. 21,6 ± 10 y 26,5 ± 12 vs. 28,8 ± 11, respectivamente. Conclusión: El incremento del diámetro interno de las fibras capilares no ha significado una mayor eficacia en el volumen convectivo ni en la capacidad depurativa.
- Published
- 2018
- Full Text
- View/download PDF
26. Does like seek like?: The formation of working groups in a programming project
- Author
-
Eduard Sanou Gozalo, Antonio Hernandez-Fernandez, Marta Arias, and Ramon Ferrer-i-Cancho
- Subjects
group formation, work in pairs, pair programming, teaching computer science, degree in computer science ,Education ,Special aspects of education ,LC8-6691 ,Technology ,Engineering (General). Civil engineering (General) ,TA1-2040 - Abstract
In a course of the degree of computer science, the programming project has changed from individual to teamed work, tentatively in couples (pair programming). Students have full freedom to team up with minimum intervention from teachers. The analysis of the couples made indicates that students do not tend to associate with students with a similar academic performance, maybe because general cognitive parameters do not govern the choice of academic partners. Pair programming seems to give great results, so the efforts of future research in this field should focus precisely on how these pairs are formed, underpinning the mechanisms of human social interactions.
- Published
- 2017
- Full Text
- View/download PDF
27. Knowledge-Based Segmentation to Improve Accuracy and Explainability in Non-Technical Losses Detection
- Author
-
Albert Calvo, Bernat Coma-Puig, Josep Carmona, and Marta Arias
- Subjects
Non-Technical Losses ,machine learning ,supervised learning ,ensemble learning ,explainability ,Technology - Abstract
Utility companies have a great interest in identifying energy losses. Here, we focus on Non-Technical Losses (NTL), which refer to losses caused by utility theft or meter errors. Typically, utility companies resort to machine learning solutions to automate and optimise the identification of such losses. This paper extends an existing NTL-detection framework: by including knowledge-based NTL segmentation, we have detected some opportunities for improving the accuracy and the explanations provided to the utility company. Our improved models focus on specific types of NTL and therefore, the explanations provided are easier to interpret, allowing stakeholders to make more informed decisions. The improvements and results presented in the article may benefit other industrial frameworks.
- Published
- 2020
- Full Text
- View/download PDF
28. Optimización del flujo del líquido de diálisis en la hemodiafiltración on-line
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Elisabeth Massó, Miquel Gómez, Lida Rodas, Giannina Bazán, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Flujo líquido diálisis ,Hemodiafiltración on-line ,Eficacia depurativa ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica más efectiva. Varios estudios aleatorizados y metaanálisis han observado una reducción de la mortalidad, con una asociación en relación directa con el volumen convectivo. En el momento presente no está bien establecido si el aumento del flujo del líquido de diálisis (Qd) puede suponer mejores resultados en términos de eficacia convectiva y depurativa. El objetivo del estudio fue valorar, en pacientes en tratamiento con HDF-OL, el efecto de la variación del Qd sobre el volumen convectivo y su capacidad depurativa. Material y métodos: Se incluyeron 59 pacientes, 45 varones y 14 mujeres que se encontraban en programa de HDF-OL con monitor 5008 Cordiax con autosustitución. Cada paciente fue analizado en 5 sesiones con HDF-OL posdilucional, con dializadores de helixona, en las que solo se varió el Qd (300, 400, 500, 600 y 700 ml/min). En cada sesión se determinaron concentración de urea (60 Da), creatinina (113 Da), β2-microglobulina (11.800 Da), mioglobina (17.200 Da) y α1-microglobulina (33.000 Da) en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción de estos solutos. Resultados: Se objetivó un aumento de litros de Qd por sesión, desde 117,9 ± 6,4 L con Qd de 300 ml/min hasta 232,4 ± 12 L con Qd 700 ml/min. No se determinaron cambios en el volumen de sustitución ni en el volumen convectivo. En términos de difusión, el incremento del Qd mostró un aumento significativo de la dosis de diálisis, con un aumento de Kt de 68 ± 6,9 L con Qd 300 ml/min hasta 75,5 ± 7,3 L con Qd 700 ml/min (p
- Published
- 2015
- Full Text
- View/download PDF
29. Optimisation of dialysate flow in on-line hemodiafiltration
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Elisabeth Massó, Miquel Gómez, Lida Rodas, Giannina Bazán, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Dialysate flow ,On-line hemodiafiltration ,Efficacy ,Convective volume ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Currently, on-line hemodiafiltration (OL-HDF) is the most effective technique. Several randomised studies and meta-analyses have shown a reduced mortality and a direct association with convective volume has been reported. At present, it has not been established if an increased dialysate flow (Qd) shows in improved results in terms of convective and depurative efficiency. We aim at assessing the effects of Qd variations on convective volume and its depurative capacity in patients on OL-HDF. Material and methods: A total of 59 patients (45 men and 14 women) from a OL-HDF programme in which a monitor 5008 Cordiax with auto-substitution was used, were enrolled. Patients were assessed in 5 sessions with post-dilutional OL-HDF, using helixone-based dialyzers, with only Qd being changed (300, 400, 500, 600 and 700 mL/min). Serum levels of urea (60 Da), creatinine (113 Da), β2-microglobulin (11,800 Da), myoglobin (17,200 Da) and α1-microglobulin (33,000 Da) were measured at the beginning and at the end of each session, in order to estimate the percent reduction of such solutes. Results: An increased dialysate volume per session was observed, from 117.9 ± 6.4 L with Qd 300 mL/min to 232.4 ± 12 L with Qd 700 mL/min. No changes were found in replacement volume or convective volume. Regarding diffusion, Qd increase was associated to a significantly increased dialysis dose, with an increased Kt from 68 ± 6.9 L with Qd 300 mL/min to 75.5 ± 7.3 L with Qd 700 mL/min (P
- Published
- 2015
- Full Text
- View/download PDF
30. Valoración de la superficie del dializador en la hemodiafiltración on-line. Elección objetiva de la superficie del dializador
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Giannina Bazan, Manel Vera, Néstor Fontseré, Elisabeth Massó, Miquel Gómez, Lida Rodas, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Autosustitución ,Hemodiafiltración on-line ,Superficie de membrana ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica más efectiva. Varios estudios aleatorizados y metaanálisis han observado una reducción de la mortalidad, objetivándose una asociación en relación directa con el volumen convectivo. En el momento presente no está bien establecido si el aumento de superficie del dializador puede suponer mejores resultados en términos de eficacia convectiva y depurativa. El objetivo del estudio fue valorar el efecto del aumento de superficie del dializador sobre el volumen convectivo y la capacidad depurativa. Material y métodos: Se incluyeron 37 pacientes (31 varones y 6 mujeres) que se encontraban en programa de HDF-OL con monitor 5008 Cordiax con autosustitución. Cada paciente fue analizado en 3 sesiones en las que solo se varió la superficie del dializador (1,0, 1,4 o 1,8 m2). En cada sesión se determinaron la concentración de urea (60 Da), creatinina (113 Da), β2-microglobulina (11.800 Da), mioglobina (17.200 Da) y α1-microglobulina (33.000 Da) en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción de estos solutos. Resultados: El volumen convectivo alcanzado fue de 29,8 ± 3,0 con 1,0 m2, de 32,7 ± 3,1 (incremento del 6%) con 1,4 m2 y de 34,7 ± 3,3 l (incremento del 16%) con 1,8 m2 (p
- Published
- 2015
- Full Text
- View/download PDF
31. Assessment of dialyzer surface in online hemodiafiltration; objective choice of dialyzer surface area
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Giannina Bazan, Manel Vera, Néstor Fontseré, Elisabeth Massó, Miquel Gómez, Lida Rodas, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Autosubstitution ,Online hemodiafiltration (OL-HDF) ,Membrane surface ,Convective volume ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Online haemodiafiltration (OL-HDF) is most effective technique; several randomised studies and meta-analyses have shown a reduction in mortality, with a directly related association with convective volume. At present, it is not properly established whether the increasing in dialyser surface area may suppose better outcomes in terms of convective and clearance efficacy. The purpose of the study was to assess the effect of increase in dialyser surface area on the convective volume and clearance capacity. Materials and methods: A total of 37 patients were included, 31 male and 6 female subjects who were participating in an OL-HDF programme with a 5008 Cordiax monitor with autosubstitution. Each patient was analysed in three sessions, and only the dialyser surface area (1.0, 1.4 or 1.8 m2) varied. In each session, urea (60 Da), creatinine (113 Da), β2-microglobulin (11,800 Da), myoglobin (17,200 Da) and α1-microglobulin (33,000 Da) serum concentration at baseline and at the end of each session were determined, so the reduction of thes solutes could be calculated. Results: Convective volume achieved was 29.8 ± 3.0 with 1.0 m2, 32.7 ± 3.1 (6% increase) with 1.4 m2 and 34.7 ± 3.3 L (16% increase) with 1.8 m2 (p
- Published
- 2015
- Full Text
- View/download PDF
32. Anatomía foliar de Tillandsia didisticha (Bromeliaceae) en la provincia de Tucumán
- Author
-
Franco Mangone, Graciela Ávila Hael, Catalina Luque, Mario Debes, Patricia L. Albornoz, and Marta Arias
- Subjects
Anatomía ,hoja ,Tillandsia didisticha ,Bromeliaceae ,Tillandsioideae ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Mangone, Franco M.; Avila Hael, Graciela N.; Luque, Catalina A.; Debes, Mario A.; Albornoz, Patricia L.; Arias, Marta E. 2011. “Anatomía foliar de Tillandsia didisticha (Bromeliaceae) en la Provincia de Tucumán”. Lilloa 48 (2). T. didisticha es una epífita nativa de Tucumán con alto valor alimenticio y medicinal. El objetivo de este trabajo fue analizar la anatomía foliar. Se trabajó con material fresco y se emplearon técnicas anatómicas convencionales. Los resultados muestran la epidermis unistrata con tejido subepidérmico y escamas típicas de Tillandsioideae. Estomas sólo en epidermis abaxial acompañados por distinto número de células subsidiarias. Mesofilo dorsiventral, parénquima acuífero; tejido clorenquimático con cristales de oxalato de calcio; aerénquima; canales mucilaginosos y macroesclereidas conectando haces colaterales. Presencia de granos de almidón en la vaina. Los caracteres anatómicos descriptos en este trabajo son relevantes como aporte para estudios taxonómicos de la subfamilia y para futuros estudios relacionados con la importancia medicinal y alimenticia de la especie.
- Published
- 2011
33. Caracterización anatómica foliar de Lonchocarpus lilloi (Fabaceae, Papilionoideae)
- Author
-
Laura F. Fernández Dattoli, Dante E. Loto, Jorge R. Flores, Catalina Luque, Mario Debes, Patricia L. Albornoz, and Marta Arias
- Subjects
Anatomía ,hoja ,Lonchocarpus ,Fabaceae ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Fernández Dattoli, Laura F.; Loto, Dante E.; Flores, Jorge R.; Luque, Catalina A.; Debes, Mario A.; Albornoz, Patricia L.; Arias, Marta E. 2011. “Caracterización anatómica foliar de Lonchocarpus lilloi (Fabaceae, Papilionoideae)”. Lilloa 48 (2). Lonchocarpus lilloi es un árbol endémico de Salta y Jujuy que habita entre 350 y 500 msnm. Mide de 10– 30 m de altura, con hojas compuestas de 4 a 6 folíolos opuestos y un folíolo terminal. El objetivo fue estudiar la anatomía foliar de esta especie. Se utilizó material fresco coleccionado en el Jardín Botánico de Fundación Miguel Lillo y en la Reserva Experimental Horco Molle y se aplicaron técnicas anatómicas convencionales. Los resultados mostraron que el folíolo es entero, simétrico, ovado y de venación pinnada. Estomas de distintos tipos: paracítico, hemiparacítico, anomocítico y anfiparacítico, en la epidermis abaxial; se observaron tricomas simples y glandulares. Pecíolo subcircular con estomas actinocíticos y tricomas simples. Los distintos tipos de estomas observados en la epidermis de lámina y pecíolo son caracteres no citados antes para esta especie. Se observaron canales esquizógenos y cristales prismáticos solitarios en lámina y pecíolo. Los caracteres diagnósticos para la identificación foliar de L. lilloi son: pulvínulo, domacio, lámina hipostomática, tipos de estomas, tricomas, cristales, estelas, venación, canales esquizógenos, conductos secretores y tubos laticíferos articulados.
- Published
- 2011
34. Anatomía foliar y radical de Urera caracasana (Urticaceae) en la provincia de Tucumán, Argentina
- Author
-
Natividad G. Ávila Hael, María A. Saracho Bottero, Jorgelina V. Medaglia, Patricia L. Albornoz, and Marta Arias
- Subjects
Anatomía ,morfología foliar ,hoja ,raíz ,Urera caracasana ,Urticaceae ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Ávila Hael, Natividad G.; María A. Saracho Bottero; Jorgelina V. Medaglia; Patricia L. Albornoz; Marta E. Arias. 2010. “Anatomía foliar y de raíz de Urera caracasana (Ur ticaceae) en la provincia de Tucumán, Argentina”. Lilloa 47 (1-2). U. caracasana se encuentra en el Bosque montano inferior, entre los 500 y 800 msnm. El objetivo del presente trabajo fue analizar la morfología y anatomía foliar y radical de esta especie. Se utilizo material fresco y fijado en FAA y se aplicaron técnicas anatómicas convencionales. Los resultados muestran que las hojas son simples, alternas con venación pinnada, caspedódroma, estructura dorsiventral, hipostomática, con cutícula lisa. La epidermis presenta tricomas eglandulares, glandulares, urticantes y aguijones. Los estomas son de tipo anisocítico y ciclocítico. Cistolitos presentes en lámina. El pecíolo es subcircular con tricomas similares a la hoja. La lámina y el pecíolo presentan haces vasculares colaterales y cristales de oxalato de calcio en forma de drusas. La raíz presenta estructura primaria de tipo diarca. Los elementos de valor diagnóstico para la identificación de esta especie son: tipos de estomas, tricomas y cristales en hoja y el tipo de estructura secundaria de raíz.
- Published
- 2010
35. Anatomía de hoja, tallo y raíz de Phenax laevigatus (Urticaceae) en la provincia de Tucumán, Argentina
- Author
-
Cecilia N. Cabrera, Patricia N. Asesor, Patricia L. Albornoz, and Marta Arias
- Subjects
Anatomía ,hoja ,tallo ,raíz ,Phenax laevigatus ,Urticaceae ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Cabrera, Cecilia N.; Patricia N. Asesor; Patricia L. Albornoz; Marta E. Arias. 2010. “Anatomía de hoja, tallo y raíz de Phenax laevigatus (Urticaceae) en la provincia de Tucumán, Argentina”. Lilloa 47 (1-2). P. laevigatus es un arbusto con un alto valor forrajero y forma par te de la dieta de herbívoros que habitan en Las Yungas, Tucumán. El objetivo del trabajo fue estudiar la anatomía de hoja, tallo y raíz. Se trabajó con material colectado en la Sierra de San Javier y el Parque Percy Hills. Para el estudio anatómico se emplearon técnicas histológicas convencionales. La lámina es dorsiventral, venación acródoma, hipostomática, con estomas anomocítico y anisocítico. Los tricomas son simples unicelulares y glandulares; se observan cistolitos y drusas. El pecíolo presenta estomas en columna y cinco haces vasculares colaterales. El tallo con crecimiento secundario temprano y secundario típico presenta fibras mucilaginosas asociadas al floema y bandas discontinuas de tejido parenquimático en el xilema. La raíz con estructura primaria tiene estela diarca y la estructura secundaria contiene granos de almidón en el parénquima xilemático. Los caracteres anatómicos descriptos son de valor diagnóstico relevante para posteriores estudios relacionados con la dieta de herbívoros
- Published
- 2010
36. Anatomía foliar de Ficus maroma (Moraceae) y análisis de hojas expuestas a la polución atmosférica en la provincia de Tucumán (Argentina)
- Author
-
Cecilia N. Cabrera, Graciela A. Gelsi, Patricia L. Albornoz, and Marta Arias
- Subjects
Anatomía foliar ,polución atmosférica ,Ficus maroma ,Moraceae ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Cabrera, Cecilia N.; Graciela A. Gelsi; Patricia L. Albornoz; Marta E. Arias, 2009. “Anatomía foliar de Ficus maroma (Moraceae) y análisis de hojas expuestas a la polución atmosférica en la provincia de Tucumán (Argentina)”. Lilloa 46 (1-2). El objetivo del trabajo fue estudiar la anatomía foliar y analizar los caracteres histológicos en hojas expuestas y no expuestas a la polución atmosférica. Las muestras fueron colectadas de ejemplares del Jardín Botánico de Fundación Miguel Lillo, Tucumán. Para el estudio anatómico se emplearon técnicas histológicas convencionales en hojas frescas y fijadas en FAA. La epidermis adaxial es pluriestratificada y la abaxial uniestratificada; los tricomas son glandulares con pie bicelular y cabeza pluricelular. Lámina dorsiventral, hipostomática, estomas tipo actinocíticos y ciclocíticos. Presencia de cistolitos, drusas y cristales cúbicos. Pecíolo subcircular con tricomas simples, colénquima subepidérmico y tres haces vasculares bicolaterales en porción media. Según el análisis estadístico los caracteres que mostraron cambios significativos fueron: aumento del grosor de la cutícula en epidermis adaxial, espesor del tejido en empalizada y mayor densidad estomática, en hojas expuestas a la polución. Se caracteriza la anatomía foliar de F. maroma y podría considerarse a esta especie como bioindicadora de la polución atmosférica
- Published
- 2009
37. Anatomía foliar de Rauvolfia schuelii Speg. (Apocynaceae), en la provincia de Tucumán, Argentina
- Author
-
Mario A. Debes, Ana C. Luque, Marta Arias, and Patricia L. Albornoz
- Subjects
Rauvolfia schuelii ,anatomía ,hoja ,Apocynaceae ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Mario Alberto Debes, Ana Catalina Luque, Marta Eugenia Arias, Patricia Liliana Albornoz. 2008. “Anatomía foliar de Rauvolfia schuelii (Apocynaceae), en la provincia de Tucumán, Argentina”. Lilloa 45 (1-2). Rauvolfia schuelii Speg. es un arbusto o arbolito de 2-6 m de altura, se distribuye en el noroeste de Argentina, entre los 450-1500 m snm. El objetivo del presente trabajo fue estudiar la anatomía foliar de Rauvolfia schuelii Speg. en la provincia de Tucumán. Se utilizó material fresco y fijado en FAA; se realizaron diafanizados, cortes transversales y longitudinales de lámina y pecíolo mediante técnicas anatómicas convencionales. Los resultados muestran que la hoja es dorsiventral, hipostomática, con cutícula estriada. Se presentan diferentes tipos de estomas: hemiparacítico, paracítico, anisocítico, tetracítico, ciclocítico y actinocítico. El pecíolo en sección transversal es subcircular con coléteres en la base. Las drusas y los haces vasculares bicolaterales se presentan en lámina y pecíolo. Los tubos latifíceros son articulados ramificados y no articulados en toda la lámina. Estos caracteres anatómicos son válidos para la correcta identificación de esta especie.
- Published
- 2008
38. Anatomía de hoja, fruto y semilla de Solanum grossum C.V. Morton y Solanum riparium Pers. (Solanaceae)
- Author
-
Gonzalo Avila, Lucía Krapovickas, Patricia Albornoz, and Marta Arias
- Subjects
Anatomía ,S. grossum ,S. riparium ,hoja ,fruto ,semilla ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Avila, Gonzalo; Lucía Krapovickas, Patricia Albornoz & Marta Arias. 2007. “Anatomía de hoja, fruto y semilla de Solanum grossum CV. Morton y Solanum riparium Pers. (Solanaceae)”. Lilloa 44 (1-2). Se estudia la anatomía de la hoja, fruto y semilla de dos especies de Solanum. S. grossum es una especie subarbórea de 2-4 m de altura, crece en el bosque entre 1200-2200 m snm; S. riparium es una especie arbórea de 2-15 m de altura y se extiende desde el Bosque Chaqueño hasta el nivel inferior del Bosque Montano. Ambas especies presentan hojas simples, alternas, con estructura dorsiventral, epidermis con tricomas eglandulares y glandulares. El fruto es una baya globosa, negra en S. grossum y morada oscura en S. riparium. Sobre la base de caracteres anatómicos tales como tipo de tricomas (glandular y eglandular), forma de cristales de oxalato de calcio, caracteres del pericarpo del fruto y tegumento seminal se puede diferenciar S. grossum de S. riparium.
- Published
- 2007
39. Migraciones y desarrollo: ¿Hay lugar para la cooperación?
- Author
-
Marta Arias Robles
- Subjects
Social Sciences - Abstract
La libre circulación de personas se presenta como uno de los aspectos todavía pendientes en el proceso de globalización. En primer lugar, en este artículo se analizan diversos aspectos que explican la decisión de los inmigrantes de abandonar su país. Igualmente diversos son los efectos de esta decisión tanto en los países de origen como en los de acogida. En segundo lugar, se afirma que la cooperación al desarrollo constituye uno de los aspectos que más puede contribuir a potenciar las oportunidades y minimizar las amenazas del fenómeno migratorio. En este línea, se cuestionan algunos de los planteamientos de la Ayuda Oficial al Desarrollo y se analizan los pasos necesarios para integrar el fenómeno migratorio en el ámbito de la cooperación. Finalmente se nos acerca a la realidad de la integración entre la cooperación española y la política de inmigración y se sugieren una serie de propuestas concretas a los distintos agentes de la cooperación.
- Published
- 2001
- Full Text
- View/download PDF
40. Anatomía de hoja y fruto de Cestrum strigillatum Ruiz et Pav. (Solanaceae)
- Author
-
Cristina Martín, María Parrado, and Marta Arias
- Subjects
Fruto ,semilla ,hoja ,Cestrum strigillatum ,anatomía ,Plant culture ,SB1-1110 ,Botany ,QK1-989 - Abstract
Cestrum strigillatum Ruiz et Pav. (Solanaceae) es un arbusto de 1,8-4 m de altura, con flores blanco-verdosas, aromáticas. El fruto es una baya morado oscuro. Habita en selvas húmedas y borde de selvas en Provincias Fitogeográficas de La Yunga, Paranaense y Chaqueña. En la anatomía de la hoja se destaca la presencia de tres tipos de tricomas: en candelabro, ramificados mixtos y glandulares. Presencia de esferocristales en el mesófilo y haz del nervio medio bicolateral. En la anatomía del fruto se observan esclereidas en el mesocarpo y engrosamientos reticulares en la testa. Se aportan caracteres diagnósticos útiles para el reconocimiento de esta especie en estudios taxonómicos, farmacobotánicos y en dieta de herbívoros.
- Published
- 2000
41. Closely-related Xanthomonas citri subsp. citri isolates trigger distinct histological and transcriptional responses in Citrus limon
- Author
-
Ingrid Georgina Orce, Mario Debes, Lorena Sendín, Ana Luque, Marta Arias, Adrián Vojnov, María Marano, Atilio Castagnaro, and María Paula Filippone
- Subjects
cDNA-AFLP ,gene expression ,canker ,plant defense ,microscopy ,Agriculture (General) ,S1-972 - Abstract
ABSTRACT Citrus canker, caused by Xanthomonas citri subsp. citri (Xcc), has an important economic impact on the citrus industry. Extensive information is available about the disease but, nevertheless, the study of plant-pathogen interactions could provide new information in the understanding of citrus canker disease. A new isolate has been identified, Xcc AT, which has a high genetic similarity (> 90 %) to the virulent Xcc T strain based on genetic clustering analyses of the rep-PCR fingerprinting patterns, but it does not produce cankerous lesions in Citrus limon. In this study, we compared C. limon responses to Xcc AT and to the virulent Xcc T strain at both histological and transcriptional levels. Histologically, leaves inoculated with Xcc AT exhibited neither a typical disordering of the spongy mesophyll, nor a swelling of epidermis. A particular content (undetermined) was also found in mesophyll cells near the stomata, together with increased starch accumulation. The transcriptomic profiles were compared by cDNA-AFLP technique. A total of 121 fragments derived from transcript (TDF) were either specifically induced or repressed by the isolates, and 62 were sequenced. Analysis of global expression identified different classes of genes known to be involved in plant-pathogen interactions. This study constitutes the first approach of the specific interaction between the avirulent Xcc AT isolate and C. limon.
- Full Text
- View/download PDF
42. ¿Es el mundo un lugar mejor para los niños?
- Author
-
Barturen, Carmelo Angulo and Robles, Marta Arias
- Published
- 2014
43. Breeding barriers between the cultivated strawberry, Fragaria × ananassa, and related wild germplasm
- Author
-
Marta, Arias E., Camadro, Elsa L., Díaz-Ricci, Juan C., and Castagnaro, Atilio P.
- Published
- 2004
- Full Text
- View/download PDF
44. Dielectric Gratings Enhancing the Field of View in Low Dielectric Permittivity Elliptical Lenses.
- Author
-
Campo, Marta Arias, Carluccio, Giorgio, Bruni, Simona, and Llombart, Nuria
- Subjects
- *
FOCAL plane arrays sensors , *DIELECTRICS , *PERMITTIVITY , *QUANTUM cascade lasers - Abstract
Low relative permittivity plastic elliptical lenses in combination with integrated focal plane arrays are a promising solution to be used in the future mm- and sub-mm-wave systems. Their appeal lies in the availability of materials with moderate loss and lightweight, and the possibility to use cost-effective manufacturing techniques. However, the achievable scanning angular range is relatively small with low permittivity lenses. In this article, we explore the use of dielectric gratings with modulated height integrated in the lens material, with the aim of enlarging the steering angle. The dielectric gratings synthesize a tilted feed pattern, reducing the reflection loss and spillover when illuminating the lens off-focus. A quasi-analytic approach based on the Floquet mode analysis of the gratings is used to synthesize the grating profile. This method is combined with an analysis in reception of the lens antenna. A wideband prototype in $G$ -band (140–220 GHz) has been fabricated, achieving a field of view of ±25° with gain >30 dBi. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
45. Wideband Circularly Polarized Antenna With In-Lens Polarizer for High-Speed Communications.
- Author
-
Campo, Marta Arias, Carluccio, Giorgio, Blanco, Darwin, Litschke, Oliver, Bruni, Simona, and Llombart, Nuria
- Subjects
- *
POLARIZERS (Light) , *FOCAL plane arrays sensors , *GREEN'S functions , *ANTENNAS (Electronics) , *NUMERICAL functions , *DIELECTRIC materials , *APERTURE antennas - Abstract
In this contribution, a broadband $G$ -band leaky-wave (LW) fed lens antenna with an integrated dielectric grid polarizer is presented. The proposed wideband polarizer unit cell geometry enables its fabrication at frequencies higher than 100 GHz, presenting high transmission properties and low axial ratio (AR). A quasi-analytic technique based on multilayer spectral Green’s function combined with a numerical Floquet modes’ solver is used to optimize the lens aperture efficiency and AR. The proposed technique is validated via full-wave (FW) simulations. A design is proposed in low dielectric permittivity material, achieving FW simulated aperture efficiency higher than 75% over 44% relative bandwidth, and an AR lower than 3 dB over 35% relative bandwidth. The antenna is able to achieve multiple directive circularly polarized (CP) beams when fed by a focal plane array, preserving the AR bandwidth. A prototype has been fabricated and measured, exhibiting an excellent agreement with quasi-analytic and FW simulations. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
46. Catheter-related bloodstream infections: predictive factors for Gram-negative bacteria aetiology and 30 day mortality in a multicentre prospective cohort.
- Author
-
Calò, Federica, Retamar, Pilar, Pérez-Crespo, Pedro María Martínez, Lanz-García, Joaquín, Sousa, Adrian, Goikoetxea, Josune, Reguera-Iglesias, José María, León, Eva, Armiñanzas, Carlos, Mantecón, Maria Angeles, Rodríguez-Baño, Jesús, López-Cortés, Luis Eduardo, REIPI/GEIH-SEIMC/SAEI, the PROBAC, Martínez Pérez-Crespo, Pedro María, PROBAC REIPI/GEIH-SEIMC/SAEI, Temprano, Marta Arias, Fernández Suárez, Jonathan, Boix, Lucía, Sánchez Calvo, Juan Manuel, and Cuquet-Pedragosa, Jordi
- Subjects
CATHETER-related infections ,GRAM-negative bacteria ,ETIOLOGY of diseases ,CENTRAL venous catheters ,SEPTIC shock ,BACTEREMIA ,RESEARCH ,RESEARCH methodology ,MEDICAL cooperation ,EVALUATION research ,SEPSIS ,COMPARATIVE studies ,LONGITUDINAL method ,CATHETERS - Abstract
Background: Catheter-related bloodstream infections (CRBSIs) increase morbidity and mortality, prolong hospitalization and generate considerable medical costs. Recent guidelines for CRBSI recommend empirical therapy against Gram-positive bacteria (GPB) and restrict coverage for Gram-negative bacteria (GNB) only to specific circumstances.Objectives: To investigate predictors of GNB aetiology in CRBSI and to assess the predictors of outcome in patients with CRBSI.Methods: Patients with CRBSI were selected from the PROBAC cohort, a prospective, observational, multicentre national cohort study including patients with bloodstream infections consecutively admitted to 26 Spanish hospitals in a 6 month period (October 2016-March 2017). Outcome variables were GNB aetiology and 30 day mortality. Adjusted analyses were performed by logistic regression.Results: Six hundred and thirty-one episodes of CRBSI were included in the study. Risk factors independently related to GNB aetiology were central venous catheter (CVC) [OR 1.60 (95% CI: 1.05-2.44), P = 0.028], sepsis/septic shock [OR: 1.76 (95% CI: 1.11-2.80), P = 0.016], antibiotic therapy in the previous 30 days [OR: 1.56 (95% CI: 1.02-2.36), P = 0.037], neutropenia <500/μL [OR: 2.01 (95% CI: 1.04-3.87), P = 0.037] and peripheral vascular disease [OR: 2.04 (95% CI: 1.13-3.68), P = 0.018]. GNB were not associated with increased mortality in adjusted analysis, while removal of catheter [OR: 0.24 (95% CI: 0.09-0.61), P = 0.002] and adequate empirical treatment [OR: 0.37 (95% CI: 0.18-0.77), P = 0.008] were strong protective factors.Conclusions: Our study reinforces the recommendation that empirical coverage should cover GNB in patients presenting with sepsis/septic shock and in neutropenic patients. Catheter removal and adequate empirical treatment were both protective factors against mortality in patients with CRBSI. [ABSTRACT FROM AUTHOR]- Published
- 2020
- Full Text
- View/download PDF
47. Assessment of functional changes in long‐standing type 1 diabetic patients without diabetic retinopathy with multifocal electroretinogram.
- Author
-
Álvarez, Marta Arias, Alonso, Sofia Bielsa, Hospital, Elvira Orduna, Tomas‐Grasa, Cristina, Sopeña‐Pinilla, Maria, Fernández‐Espinosa, Guisela, Díaz‐Barreda, Mª. Dolores, Mena, Diego Rodríguez, Acha, Javier, and Pinilla, Isabel
- Subjects
- *
DIABETIC retinopathy , *PEOPLE with diabetes , *ELECTRORETINOGRAPHY , *FUNCTIONAL assessment , *CONTROL groups , *AGE groups - Abstract
Aims/Purpose: To early evaluate local functional changes in the retina of long‐standing type 1 diabetic patients (DM1) without diabetic retinopathy (DR) through the use of multifocal electroretinogram (mfERG). Methods: 46 eyes of 46 long‐standing DM1 patients without DR and 46 eyes of 46 healthy subjects were studied. Eyes with previous history of ocular diseases that could alter mfERG results were excluded. Participants were evaluated using mfERG with RETIscan recording system by Roland, following the standardized international guidelines of the International Society for Clinical Electrophysiology of Vision (ISCEV). The electrical density and implicit time of each first‐order response (K1) were measured and analysed in both study groups, as well as interocular differences. Results: Mean age was 48.00 ± 9.77 years in the DM1 group and 51.69 ± 4.75 years in the control group. The average duration of diabetes was 29.19 ± 7.85 years and the mean HbA1c level was 7.33 ± 0.9%. No statistically significant differences were found between the ages of the groups. In mfERG, a statistically significant decrease in P1 response density was recorded in the R1 ring (central 0°‐2°) in the DM1 group compared to the control subjects (p = 0.029). Additionally, the R1/R2 ratio was significantly lower in diabetic patients than in the control group (p = 0.009). There was also a statistically significant increase in the implicit time of P1 in the R5 ring (central >15°) in the DM1 group compared to the control group (p = 0.027). No interocular differences were found in the DM1 group. Regarding quadrant analysis, no statistically significant differences were found in the DM1 group. Conclusions: In patients with long‐standing DM1 without RD, mfERG enables the detection of subclinical and local findings, which indicates the presence of a pre‐existing neurodegenerative process prior to the onset of retinal lesions. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
48. Multifocal electroretinogram in the diagnosis of Stargardt disease.
- Author
-
Sopeña‐Pinilla, Maria, Álvarez, Marta Arias, Fernández‐Espinosa, Guisela, Alonso, Sofia Bielsa, Tomas‐Grasa, Cristina, Boned‐Murillo, Ana, Díaz‐Barreda, Mª. Dolores, Hospital, Elvira Orduna, and Pinilla, Isabel
- Subjects
- *
STARGARDT disease , *DIAGNOSIS , *RETINAL diseases , *ELECTRORETINOGRAPHY , *FLUORESCENCE angiography - Abstract
Aims/Purpose: Electrophysiological vision tests have been a key method in the diagnosis and monitoring of inherited retinal dystrophies (IRD). With the development of mfERG, the clinical applications of these tests have expanded to cone dystrophies such as Stargardt disease, which is the most common cone‐IRD. This disease is typically associated with an autosomal recessive inheritance pattern, primarily, although not exclusively, due to mutations in the ABCA4 gene. The introduction of different diagnostic techniques such as Optical Coherence Tomography (OCT), OCT Angiography (OCTA), autofluorescence (FAF) and microperimetry has diminished the importance of fluorescein angiography (FA). These techniques have been joined by the diagnostic role of mfERG. The aim of this study is to evaluate functional changes in patients with Stargardt disease using mfERG. Methods: Eighteen eyes of patients with Stargardt disease were included. The disease was previously confirmed by genotyping with homozygous ABCA4 mutations or heterozygous PROM1 mutations. The patients were evaluated using mfERG, using the standardized international ISCEV guidelines. Electrical density and implicit time of each first‐order response (K1) in the five concentric rings centered on the fovea were measured and analysed. Results: Mean best‐corrected visual acuity (BCVA) was 0.5 (0.12–1.0). First‐order responses (K1) showed a decreased electrical density, predominantly in central rings, along with minimally prolonged latencies of the P1. FAF showed central atrophy in 6 patients, atrophy with flecks within or beyond the vascular branches in 8 and 4 patients respectively. Conclusions: Stargardt disease involves cones and is characterized by a significant decrease in foveal and central response in mfERG, even in early stages when BCVA remains relatively preserved and fundus findings are minimal. Flash ERG may show normal results or minimal abnormalities. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
49. Optic nerve disorders and reduced visual acuity in children. Differential diagnosis.
- Author
-
Díaz‐Barreda, Mª. Dolores, Boned‐Murillo, Ana, Fernández‐Espinosa, Guisela, Sopeña, María, Álvarez, Marta Arias, and Pinilla, Isabel
- Subjects
OPTIC nerve ,VISUAL acuity ,VISION disorders ,DIFFERENTIAL diagnosis ,FUNDUS oculi ,EXOTROPIA - Abstract
Aims/Purpose: Low visual acuity (VA) in children requires meticulous investigation in search of possible organic causes. Once an alteration in the optic nerve (ON) has been detected, differential diagnosis is essential due to the different prognosis and management of each entity. Methods: We report the case of a 10‐year‐old black girl who went to the ophthalmologist for decreased VA in the left eye (LE) with no other history, signs or symptoms. On examination she had VA in the right eye (RE) 1 (Snellen decimal scale) and 0.1 LE. No torticollis or stereopsis, exotropia and convergence deficit in the LE. Normal fundus of eye (FE) RE; LE papilla larger and pale, centred staphylomatous excavation with central whitish area, vessels emanating from the periphery of the ON and alteration of the surrounding pigmentation, peripheral retina hypopigmented. Optical coherence tomography (OCT) of macula was normal; of the ON was very altered. Ultrasound showed protrusion of the LE "bottleneck" disc. Results: In view of the suspicion of Morning Glory Syndrome (MGS), magnetic resonance imaging (MRI) and angio‐MRI were requested to rule out alterations in the central nervous system (CNS), especially vascular malformations. After explaining the findings and poor visual prognosis we opted for occlusions in the RE, improving VA to 0.2 OI. We consulted paediatrics, genetic testing and close follow‐up, paying special attention to the retina due to the association with choroidal neovascularisation (CNV) and retinal detachment (RD). Conclusions: The characteristics of MGS can be confused with other pathologies, especially ON coloboma. Peripapillary staphyloma, ON dysplasia or aplasia, advanced glaucoma, Aicardi's disease and Papillorenal disease must be ruled out. Once diagnosed, possible systemic associations must be studied due to their potential severity and follow‐up is essential, as a high percentage will present ophthalmological complications. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
50. Lesión renal aguda poscontraste en pacientes con cáncer Post-contrast acute kidney injury in cancer patients.
- Author
-
de Francisco, Angel L. M., Guillén, Marta Arias, Pérez-Valderrama, Begoña, and Sebastia, Carmen
- Published
- 2019
- Full Text
- View/download PDF