14 results on '"Vedovatto, Eduardo"'
Search Results
2. Influência do tipo de moldeira e alívios nas alterações do contorno do palato = The effect of tray type and relief space on the palate outline changes
- Author
-
Gennari Filho, Humberto, Vedovatto, Eduardo, Cunha, Lígia Del'Arco Pignatta, Shibayama, Ricardo, and Mazaro, José Vitor Quinelli
- Subjects
lcsh:RK1-715 ,lcsh:Dentistry ,ODONTOLOGIA ,MATERIAIS DENTÁRIOS ,MOLDAGEM (ODONTOLOGIA) - Abstract
A estabilidade do molde é um dos fatores de maior importância para obtenção de um modelo fiel, sendo o cuidado com a individualização da moldeira, extremamente, necessário. Tendo em vista que tanto a espessura do molde como as retenções da moldeira (ou sua associação) podem influenciar na estabilidade do molde durante sua remoção da boca, o propósito desse estudo foi o de investigar a influência do alívio e da perfuração da moldeira, na alteração do molde de alginato, decorrentes do ato de remoção, avaliando a inclinação do perfil do palato na região média e posterior através de computação gráfica. Para tanto foi confeccionada uma matriz em resina acrílica representando um maxilar edêntulo, sendo essa matriz plana na região do palato e vertentes interna do rebordo alveolar. Foram confeccionadas moldeiras em resina acrílica com 3 diferentes alívios (3 mm, 4,5 mm e 6 mm) sendo um grupo com perfuração e outro sem perfuração, totalizando em 6 grupos estudados. O material de eleição para a realização das moldagens foi o Jeltrate Plus (Dentsply), sendo realizadas 7 impressões para cada grupo. Após a obtenção dos modelos, com gesso tipo IV, os mesmos foram digitalizados e os perfis (tanto posterior como mediano) mensurados no software AutoCad 2000. Os resultados permitiram concluir que: a moldeira perfurada com pouco alívio (3mm) representou a melhor situação, sendo suas médias não estatisticamente diferentes em relação à matriz. Não ocorreram diferenças estatisticamente significantes (p
- Published
- 2005
3. Effect of Mechanical Cycling on Screw Torque in External Hexagon Implants with and without Platform Switching
- Author
-
Carvalho, Bruno Andrade Cantharino de, primary, Vedovatto, Eduardo, additional, Carvalho, Paulo Sérgio Perri de, additional, Mazaro, José Vitor Quinelli, additional, and Falcón-Antenucci, Rosse Mary, additional
- Published
- 2015
- Full Text
- View/download PDF
4. Movimentação dos dentes artificiais em próteses totais com diferentes profundidades de palato
- Author
-
Vedovatto, Eduardo [UNESP], Universidade Estadual Paulista (Unesp), and Gennari Filho, Humberto [UNESP]
- Subjects
Resinas acrilicas ,Acrylic resins ,Dente artificial ,Denture, Complete ,Dental prosthesis ,Palate ,Prótese total ,Palato ,Prótese dentária - Abstract
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-25Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 vedovatto_e_dr_araca.pdf: 365938 bytes, checksum: bd1dd616abe7c6a4bce474ab109acd1f (MD5) Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato... Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey's and Fisher's post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical... (Complete abstract click electronic access below)
- Published
- 2009
5. Techniques used for making of facial prostheses
- Author
-
marcelo Coelho goiato, Vedovatto, Eduardo, Mazaro, José Vitor Quinelli, Matida Hamata, Marcelo, Gennari Filho, Humberto, Falcón, Rose Mary, Santos, Daniela Micheline Dos, and Universidade Estadual Paulista (Unesp)
- Subjects
Facial prosthesis - Abstract
Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-27T11:23:51Z No. of bitstreams: 0Bitstream added on 2014-05-27T14:30:17Z : No. of bitstreams: 1 2-s2.0-67650092276.pdf: 392207 bytes, checksum: b2be3774a423742148cde1e915075c5f (MD5) Made available in DSpace on 2014-05-27T11:23:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-01-01 Facial prostheses are a integral part of rehabilitation of patients underwent face damages, being of pathologic, traumatic or congenital origin. Although success of treatment with facial prostheses is associated with artistic ability of professional to reproduce lost structures, we can not to obviate the good adaptability of prostheses regards association of material and techniques used to make buccomaxillofacial prostheses. Facultad de Odontología de Araçatuba UNESP Departamento de Materiales Odontológicos y Prótesis Facultad de Odontología de Araçatuba UNESP Facultad de Odontología de Araçatuba UNESP Departamento de Materiales Odontológicos y Prótesis Facultad de Odontología de Araçatuba UNESP
- Published
- 2009
6. Analysis of the change in maxillary dentures teeth position in assignment to the size arch
- Author
-
Gennari Filho, Humberto, Negrão Alves, Luciana Mara, dos Santos, Paulo Henrique, Coelho Goiato, Marcelo, Vedovatto, Eduardo, and Shibayama, Ricardo
- Subjects
resinas acrílicas ,Artificial teeth ,dientes artificiales ,Maxillary complete denture ,Prótesis maxilar ,microondas ,acrylic Resins ,Microwaves - Abstract
RESUMEN El propósito de este trabajo fue analizar en prótesis totales maxilares la influencia del tamaño de los arcos en el movimiento de dientes artificiales cuando los mismos se someten a las inclusiones con barrera de yeso tipo IV (especial), polimerizado en microondas y medidas gráficamente por computadora. Veinte y una réplicas de prótesis que se habían construido previamente, fueran divididos en tres grupos: grupo 1, constituido de 7 prótesis maxilares del tamaño pequeño; grupo 2, constituido de 7 prótesis de tamaño medio y, grupo 3, de gran tamaño. Las prótesis habían sido medidas en puntos demarcados previamente en los dientes, con un programa de computación gráfica, después del encerado y después de la polimerización y demuflado. La diferencia entre la medida, en las dos etapas, demostró la ocurrencia de pequeñas alteraciones. Fue concluido, del punto de vista estadístico, que no ha tenido diferencias significativas en las alteraciones de la posición de dientes, en los tres tamaños de modelos estudiados. ABSTRACT The purpose of this study was to evaluate the influence of maxillary arch size on the artificial teeth movement in complete dentures. The maxillary dentures were processed with a barrier-type IV gypsum molding technique, and polymerized by microwave energy. Twenty one dentures were fabricated and equally divided into 3 groups, according to maxillary residual ridge size: G1) small; G2) medium and G3) large size. Reference points were made on the incisal edges of the central incisors and the supporting cusps of the premolar and second molar teeth. Linear distances among reference points, in a horizontal plane, were measured with a computer program (Auto cad 2000) before and after processing denture. Although there were differences between measurements, indicating some movement degree among artificial teeth, the results showed no statistical significantly differences among three groups studied. It was concluded that the maxillary arch size has not influence on the artificial teeth position
- Published
- 2007
7. Influencia en los modelos del alisamiento de las impresiones de alginato con el dedo humedecido
- Author
-
Gennari Filho, Humberto, Vedovatto, Eduardo, Quinelli Mazaro, José Vitor, Coelo Goiato, Marcelo, and Dos Santos, Paulo Henrique
- Subjects
Dental models ,Alginates ,Alginato ,Modelos ,Dental impression technique ,Alisamiento ,Impresiones ,Dental impression materials - Abstract
El objetivo del estudio fue evaluar la presencia de burbujas superficiales y la alteración dimensional en los modelos obtenidos de impresiones de alginato, con y sin alisamiento con el dedo humedecido en agua. Se hizo una matriz en resina acrílica del maxilar desdentado cuyo paladar se modificó para que presentara una superficie llana y lisa y se insertaron 5 pernos metálicos en la cresta del reborde en lugares predeterminados. El estudio se dividió en 6 grupos de acuerdo con la técnica de impresión y del material usado (Jeltrate, Jeltrate plus e Hidrogum), con un total de 10 modelos para cada grupo. El paladar de los modelos se valoró con lupa (50 aumentos) lo que permitió la estimación de las burbujas. La lectura de los modelos se hizo por digitalización de los modelos, midiendo la distancia entre los pernos con el software AutoCAD 2000. Los datos según el análisis de la varianza (ANOVA) y el test de Tukey (5%) indicaron una reducción significativa en el porcentaje de burbujas cuando se hacia el alisamiento. Los modelos donde se hizo el alisamiento presentaran alteraciones sin diferencias estadísticamente significativas respecto a los grupos donde no se hizo el alisamiento. El análisis de los resultados permitió concluir que el alisamiento del alginato con el dedo humedecido no afectó la precisión de los modelos del yeso en ningunos de los alginatos probados. El alisado dio lugar a una reducción significativa en el número de burbujas superficiales. The purpose of this study was to evaluate the presence of superficial bubbles and dimensional changes of three types of irreversible hydrocolloids smoothened with a moist finger and not smoothened. A master die was made with acrylic resin, representing an edentulous maxillary palate that was modified in order to provide a flat surface. Five pins were inserted in the alveolar crest at predetermined areas. The study was divided in 6 groups in agreement with the molding technique and the hydrocolloid material (Jeltrate, Jeltrate Plus and Hidrogum). These consisted of 10 impressions for each group. The palate region of the molds was assessed with a microscope (50x) to allow bubble scoring. The mold was immediately poured with type IV dental stone. The casts were scanned and digitalized. The distances between pins were measured employing AutoCAD 2000. The data was submitted to ANOVA and Tukey´s test with significance level of 5%. There were no significant differences between cast accuracy obtained from either impression technique regardless of the alginate tested. From the results obtained it was concluded that the presence of bubbles was significantly higher (p < 0.05) in the groups that water rinsing with was not performed; the alginate «Jeltrate» showed a larger discrepancy between both techniques (with and without moist finger smoothening).
- Published
- 2007
8. Influência do tipo de moldeira e alívios nas alterações do contorno do palato
- Author
-
Gennari-Filho, Humberto, Vedovatto, Eduardo, Cunha, Lígia Del’Arco Pignatta, Shibayama, Ricardo, and Mazaro, José Vitor Quinelli
- Abstract
A estabilidade do molde é um dos fatores de maior importância para obtenção de um modelo fiel, sendo o cuidado com a individualização da moldeira, extremamente, necessário. Tendo em vista que tanto a espessura do molde como as retenções da moldeira (ou sua associação) podem influenciar na estabilidade do molde durante sua remoção da boca, o propósito desse estudo foi o de investigar a influência do alívio e da perfuração da moldeira, na alteração do molde de alginato, decorrentes do ato de remoção, avaliando a inclinação do perfil do palato na região média e posterior através de computação gráfica. Para tanto foi confeccionada uma matriz em resina acrílica representando um maxilar edêntulo, sendo essa matriz plana na região do palato e vertentes interna do rebordo alveolar. Foram confeccionadas moldeiras em resina acrílica com 3 diferentes alívios (3 mm, 4,5 mm e 6 mm) sendo um grupo com perfuração e outro sem perfuração, totalizando em 6 grupos estudados. O material de eleição para realização das moldagens foi o Jeltrate Plus (Dentsply), sendo realizadas 7 impressões para cada grupo. Após a obtenção dos modelos, com gesso tipo IV, os mesmos foram digitalizados e os perfis (tanto posterior como mediano) mensurados no software AutoCad 2000. Os resultados permitiram concluir que: a moldeira perfurada com pouco alívio (3mm) representou a melhor situação, sendo suas médias não estatisticamente diferentes em relação à matriz. Não ocorreram diferenças estatisticamente significantes (p < 0,05) entre os grupos em que se utilizaram moldeiras sem perfuração em relação às moldeiras perfuradas. UNITERMOS: alginatos; materiais para moldagem odontológica; técnica de moldagem odontológica. SUMMARY The stability of the mold is one of the most important factors to obtaining a accuracy impression and the care with the custom trays extremely necessary. Thus, from a view that as the thickness of the mold as the retentions of the tray can be influence in the stability of the impression during the removal of the mouth, the purpose of this study was to investigate the influence of the relief space and the perforation of the tray on the alteration of the irreversible hydrocolloid impressions, current of the removal action, evaluating the inclination of the outline of the palate in the anterior and posterior area through graphic computation. A master model was made in acrylic resin representing an edentulous maxillary that was plane in the palatal area and in the internal slope of the alveolar edge. Trays were made in acrylic resin with 3 different relief (3 mm, 4,5 mm and 6 mm) being a group with perforation and other without perforation, totaling in 6 studied groups. The election material necessáfor accomplishment the impression was Jeltrate Plus (Dentsply), being accomplished 7 impressions for each group. After obtaining of the casts with plaster type IV, the same ones were scanned and the anterior and posterior profile reading in the software AutoCad 2000. The results allowed to concluded that: the perforated tray with relief (3 mm) represented the best situation, with the averages no statistically different in relation to the master model. The study did not showed differences statistically significant (p < 0,05) among the groups in that trays was used without perforation in relation to the perforated trays. UNITERMS: alginates; dental impression materials; dental impression technique.
- Published
- 2007
9. Influência do processamento de próteses totais superiores em função da profundidade do palato: análise da movimentação dos dentes artificiais por computação gráfica
- Author
-
Vedovatto, Eduardo [UNESP], Universidade Estadual Paulista (Unesp), and Gennari Filho, Humberto [UNESP]
- Subjects
Acrylic resins ,Palate ,Protese dentaria completa ,Resinas acrilicas dentarias ,Prótese total ,Complete denture ,Palato - Abstract
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 vedovatto_e_me_araca.pdf: 3678407 bytes, checksum: 61a0add7350fb3375bfca3d4c3dcaff0 (MD5) Universidade Estadual Paulista (UNESP) Em função do relacionamento existente entre a profundidade do palato e as alterações das bases de resina acrílica, esse trabalho investigou a movimentação dos dentes que ocorrem quando próteses totais são processadas com diferentes materiais e técnicas e a relação com o formato do palato. Foram confeccionadas vinte e oito réplicas de próteses totais sobre modelos maxilares com palato raso e vinte e oito réplicas para o palato profundo, idênticas quanto ao enceramento e posicionamento dos dentes. As próteses foram divididas em oito grupos com sete espécimes cada, de acordo com o tipo de resina utilizada, o material utilizado para inclusão em mufla e o tipo de palato. Foram demarcados pontos sobre os dentes que serviram de referência para as mensurações através do software AutoCAD 2005. As mensurações foram realizadas em dois estágios: após o enceramento das próteses e após a demuflagem (não separadas do modelo). Os resultados foram submetidos à análise de variância e as comparações ao teste de Tukey com probabilidade de 5%. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos estudados, porém quando a análise ocorreu num contexto geral, diferença estatisticamente significativa foi observada para as variáveis, formato de palato e material de inclusão. Baseado nos resultados pode-se concluir que: o formato do palato influencia nas alterações dos dentes artificiais; o palato profundo sofreu alterações dentais significantemente inferiores que o palato raso; as próteses incluídas com silicone apresentaram alterações significantemente superiores às incluídas com gesso; o tipo de resina utilizada não acarretou em alterações estatísticamente significantes entre si; a região posterior das próteses apresentou maiores alterações em relação à região anterior. About the relationship between the palate depth and the changes in acrylic resins base-plate, this work investigate the teeth movement that occurs when the complete dentures were processed by different materials, techniques and its relation to the palatal form. Twenty eight samples of complete dentures in maxillary cast with shallow palate form and twenty eight with deep palate form were constructed for the study. The samples presented similarities in the artificial teeth position. This prosthesis were divided in eight groups with seven specimens each, in agreement with the resin type for inclusion, the type of material used in the covering and the type of the palate depth. Points were demarcated on the teeth, which served as reference for the measurements of the segments (among the teeth), through software AutoCAD 2005. The measurements are accomplished in two moments: after the waxed and after the desflasking (not descasting). The results were submitted to the analysis of variance and comparisons to the Tukeyþs test with probability of 5%. The results showed no statistical significantly differences between the groups, but when the variables were study in global context difference were observed for the palatal form and covering materials. Based on the results conclude that: the palatal form influence on the changes of teeth position. The deep palate showed alterations significantly inferior that presented for the shallow palate. The silicon used for the covering results in greater alterations in relation to the stone mold. The type of resin not differs in the alterations of teeth position (not significantly). The change of teeth position was greater in the posterior region compares to the anterior region of the prosthesis.
- Published
- 2005
10. Avaliação comparativa da posição relativa dos dentes artificiais entre três
- Author
-
Filho, Humberto G., primary, Vedovatto, Eduardo, additional, Assunção, Wirley G., additional, and Shibayama, Ricardo, additional
- Published
- 2010
- Full Text
- View/download PDF
11. Avaliação da qualidade de superfície de moldes obtidos a partir de duas técnicas de moldagem utilizando-se três marcas de alginato
- Author
-
G. Filho, Humberto, primary, Vedovatto, Eduardo, additional, Mazaro, José V. Q., additional, Assunção, Wirley G., additional, and Santos, Paulo H., additional
- Published
- 2010
- Full Text
- View/download PDF
12. Estudo comparativo entre duas resinas acrílicas e dois silicones utilizados para o processamento de próteses totais através da análise bidimensional da posição dos dentes artificiais
- Author
-
Goiato, Marcelo C., primary, Amantéa, Daniele C. Z., additional, Vedovatto, Eduardo, additional, Gennari Filho, Humberto, additional, Assunção, Wirley G., additional, and Santos, Daniela M. dos, additional
- Published
- 2010
- Full Text
- View/download PDF
13. Análise da movimentação dos dentes artificiais em próteses totais superiores. Influência do tipo de polimento.
- Author
-
Goiato, Marcelo C., primary, Vedovatto, Eduardo, additional, Amantéa, Daniela C. Z., additional, G. Filho, Humberto, additional, and Marinho, Marcio L. V. D., additional
- Published
- 2010
- Full Text
- View/download PDF
14. Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching.
- Author
-
de Carvalho BA, Vedovatto E, de Carvalho PS, Mazaro JV, and Falcón-Antenucci RM
- Subjects
- Bone Screws, Dental Implants, Prosthesis Design, Torque
- Abstract
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
- Published
- 2015
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.