10 results on '"Oldaker, Teri"'
Search Results
2. ICCS Women in Cytometry-Impact 10 years later: A call to promote gender equity.
- Author
-
Bunting ST, Oldaker T, Qualtieri J, O'Donahue M, Maremont S, Harricharran H, Kelliher A, Kdouh L, Devitt K, Cherian S, Stetler-Stevenson M, and Moore J
- Subjects
- Female, Gender Equity, Humans, Sex Factors, Flow Cytometry methods
- Published
- 2021
- Full Text
- View/download PDF
3. Flow cytometric method transfer: Recommendations for best practice.
- Author
-
Cabanski M, Oldaker T, Stewart JJ, Selliah N, Eck S, Green C, Litwin V, and Vitaliti A
- Subjects
- Humans, Flow Cytometry
- Abstract
As with many aspects of the validation and monitoring of flow cytometric methods, the method transfer processes and acceptance criteria described for other technologies are not fully applicable. This is due to the complexity of the highly configurable instrumentation, the complexity of cellular measurands, the lack of qualified reference materials for most assays, and limited specimen stability. There are multiple reasons for initiating a method transfer, multiple regulatory settings, and multiple context of use. All of these factors influence the specific requirements for the method transfer. This recommendation paper describes the considerations and best practices for the transfer of flow cytometric methods and provides individual case studies as examples. In addition, the manuscript emphasizes the importance of appropriately conducting a method transfer on data reliability., (© 2020 International Clinical Cytometry Society.)
- Published
- 2021
- Full Text
- View/download PDF
4. High-sensitivity flow cytometric assays: Considerations for design control and analytical validation for identification of Rare events.
- Author
-
Sommer U, Eck S, Marszalek L, Stewart JJ, Bradford J, McCloskey TW, Green C, Vitaliti A, Oldaker T, and Litwin V
- Subjects
- Equipment Design, Humans, Flow Cytometry instrumentation
- Abstract
The current consensus recommendation papers dealing with the unique requirements for the analytical validation of assays performed by flow cytometry address the validation of sensitivity (both analytical and functional) only in general terms. In this paper, a detailed approach for designing and validating the sensitivity of rare event methods is described. The impact of panel design and optimization on the lower limit of quantification (LLOQ) and suggestions for reporting data near, or below, the LLOQ are addressed. This paper serves to provide best practices for the development, optimization, and analytical validation of flow cytometric assays designed to assess rare events. Note that this paper does not discuss clinical sensitivity validation, which addresses the positive and negative predictive value of the test result., (© 2020 International Clinical Cytometry Society.)
- Published
- 2021
- Full Text
- View/download PDF
5. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders part 4 - assay validation and quality assurance.
- Author
-
Oldaker T, Whitby L, Saber M, Holden J, Wallace PK, and Litwin V
- Subjects
- Consensus, Humans, Sensitivity and Specificity, Flow Cytometry standards, Glycosylphosphatidylinositols metabolism, Hemoglobinuria, Paroxysmal diagnosis, Hemoglobinuria, Paroxysmal metabolism
- Abstract
Over the past six years, a diverse group of stakeholders have put forth recommendations regarding the analytical validation of flow cytometric methods and described in detail the differences between cell-based and traditional soluble analyte assay validations. This manuscript is based on these general recommendations as well as the published experience of experts in the area of PNH testing. The goal is to provide practical assay-specific guidelines for the validation of high-sensitivity flow cytometric PNH assays. Examples of the reports and validation data described herein are provided in Supporting Information. © 2017 International Clinical Cytometry Society., (© 2017 International Clinical Cytometry Society.)
- Published
- 2018
- Full Text
- View/download PDF
6. Flow cytometry quality requirements for monitoring of minimal disease in plasma cell myeloma.
- Author
-
Oldaker TA, Wallace PK, and Barnett D
- Subjects
- Antigens, CD genetics, Antigens, CD immunology, Antineoplastic Agents therapeutic use, Biomarkers, Pharmacological analysis, Bone Marrow Cells drug effects, Bone Marrow Cells immunology, Bone Marrow Cells pathology, Drug Approval, Gene Expression, Humans, Immunophenotyping, Limit of Detection, Multiple Myeloma drug therapy, Multiple Myeloma immunology, Multiple Myeloma mortality, Neoplasm, Residual drug therapy, Neoplasm, Residual immunology, Neoplasm, Residual mortality, Plasma Cells drug effects, Plasma Cells immunology, Plasma Cells pathology, Prognosis, Quality Control, Remission Induction, Survival Analysis, Time Factors, Antigens, CD analysis, Drugs, Investigational therapeutic use, Flow Cytometry standards, Multiple Myeloma diagnosis, Neoplasm, Residual diagnosis
- Abstract
Current therapeutic approaches for plasma cell myeloma (PCM) attain an overall survival of more than 6 years for the majority of newly diagnosed patients. However, PFS and OS are the only accepted FDA clinical endpoints for demonstrating drug efficacy before they can be become frontline therapeutic options. There is, however, recognition that the increasing gap between drug development and approval for mainstream therapeutic use needs to be shortened. As such regulatory bodies such as the FDA are now considering whether biomarker response evaluation, as in measurement of minimal residual disease (MRD) as assessed by flow cytometry (FC), can provide an early, robust prediction of survival and therefore improve the drug approval process. Recently, FC MRD using a standardized eight-color antibody methodology has been shown to have a minimum sensitivity of 0.01% and an upper sensitivity of 0.001%. To ensure that all laboratories using this approach achieve the same levels of sensitivity it is crucially important to have standardized quality management procedures in place. This manuscript accompanies those published in this special issue and describes the minimum that is required for validating and quality monitoring of this highly specific test to ensure any laboratory, irrespective of location, will achieve the expected quality standards required., (© 2015 International Clinical Cytometry Society.)
- Published
- 2016
- Full Text
- View/download PDF
7. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part I - rationale and aims.
- Author
-
Davis BH, Wood B, Oldaker T, and Barnett D
- Subjects
- Flow Cytometry standards, Fluorescence, Humans, Practice Guidelines as Topic, Reference Standards, United States, United States Food and Drug Administration, Clinical Laboratory Techniques methods, Flow Cytometry methods, Hematology standards, Immunohistochemistry methods
- Abstract
Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part I - Rationale and aims. © 2013 International Clinical Cytometry Society., (© 2013 International Clinical Cytometry Society.)
- Published
- 2013
- Full Text
- View/download PDF
8. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part IV - postanalytic considerations.
- Author
-
Barnett D, Louzao R, Gambell P, De J, Oldaker T, and Hanson CA
- Subjects
- Flow Cytometry standards, Humans, Practice Guidelines as Topic, Reference Standards, United States, United States Food and Drug Administration, Clinical Laboratory Techniques methods, Flow Cytometry methods, Fluorescent Dyes, Hematology standards
- Abstract
Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called home brew assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part IV - Postanalytic considerations., (© 2013 International Clinical Cytometry Society.)
- Published
- 2013
- Full Text
- View/download PDF
9. 2006 Bethesda International Consensus recommendations on the immunophenotypic analysis of hematolymphoid neoplasia by flow cytometry: optimal reagents and reporting for the flow cytometric diagnosis of hematopoietic neoplasia.
- Author
-
Wood BL, Arroz M, Barnett D, DiGiuseppe J, Greig B, Kussick SJ, Oldaker T, Shenkin M, Stone E, and Wallace P
- Subjects
- Cell Lineage, Flow Cytometry standards, Hematologic Neoplasms pathology, Humans, Immunophenotyping standards, Indicators and Reagents, Quality Control, Flow Cytometry methods, Hematologic Neoplasms diagnosis, Hematologic Neoplasms metabolism, Immunophenotyping methods
- Abstract
Immunophenotyping by flow cytometry has become standard practice in the evaluation and monitoring of patients with hematopoietic neoplasia. However, despite its widespread use, considerable variability continues to exist in the reagents used for evaluation and the format in which results are reported. As part of the 2006 Bethesda Consensus conference, a committee was formed to attempt to define a consensus set of reagents suitable for general use in the diagnosis and monitoring of hematopoietic neoplasms. The committee included laboratory professionals from private, public, and university hospitals as well as large reference laboratories that routinely operate clinical flow cytometry laboratories with an emphasis on lymphoma and leukemia immunophenotyping. A survey of participants successfully identified the cell lineage(s) to be evaluated for each of a variety of specific medical indications and defined a set of consensus reagents suitable for the initial evaluation of each cell lineage. Elements to be included in the reporting of clinical flow cytometric results for leukemia and lymphoma evaluation were also refined and are comprehensively listed. The 2006 Bethesda Consensus conference represents the first successful attempt to define a set of consensus reagents suitable for the initial evaluation of hematopoietic neoplasia., (Copyright 2007 Clinical Cytometry Society.)
- Published
- 2007
- Full Text
- View/download PDF
10. 2006 Bethesda International Consensus recommendations on the immunophenotypic analysis of hematolymphoid neoplasia by flow cytometry: recommendations for training and education to perform clinical flow cytometry.
- Author
-
Greig B, Oldaker T, Warzynski M, and Wood B
- Subjects
- Hematologic Neoplasms pathology, Humans, Models, Educational, Education, Flow Cytometry methods, Hematologic Neoplasms diagnosis, Immunophenotyping methods, Professional Competence standards
- Abstract
As clinical flow cytometry practices continue to expand and immunophenotyping for leukemia and lymphoma becomes more widespread, the need for defined guidelines for training of medical professionals is imperative. Standards of expected knowledge and skills are necessary to ensure reliable test results as well as provide direction to those who are considering adding flow cytometry to their clinical laboratory practice. Before now, no clear guidelines have been established for defining the areas of responsibility, education and training standards, and credentials that would be required to perform clinical flow cytometry for leukemia and lymphoma. As part of the 2006 Bethesda Consensus conference, a committee was formed to address this need and provide recommendations for training and education. The committee included laboratory professionals from private, public, and university hospitals as well as large reference laboratories that routinely operate clinical flow cytometry laboratories with an emphasis on lymphoma and leukemia immunophenotyping. This document represents the work of the committee. Categories of work responsibility are defined and the requisite education, training, and credentials, as well as measurement methods for assessing competency for each area of responsibility are provided. Additional recommendations are included that promote creating a specialty certification in flow cytometry, establishing benchmarks for training technologists and interpreters, and offer suggestions for minimum levels of experience to direct a clinical flow cytometry laboratory., (Copyright 2007 Clinical Cytometry Society.)
- Published
- 2007
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.