19 results on '"Salvagno, G. L."'
Search Results
2. Sodium citrate blood contamination by K2-ethylenediaminetetraacetic acid ( EDTA): impact on routine coagulation testing.
- Author
-
Lima‐Oliveira, G., Salvagno, G. L., Danese, E., Favaloro, E. J., Guidi, G. C., and Lippi, G.
- Subjects
- *
COLLECTION & preservation of biological specimens , *BLOOD coagulation , *BLOOD coagulation tests , *CITRATES , *CONFIDENCE intervals , *CLINICAL pathology , *ETHYLENEDIAMINETETRAACETIC acid , *FIBRINOGEN , *PROBABILITY theory , *DESCRIPTIVE statistics , *PARTIAL thromboplastin time , *PROTHROMBIN time , *IN vitro studies - Abstract
Introduction The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time ( APTT), prothrombin time ( PT), and fibrinogen. Methods Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. Results A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. Conclusion The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
3. Allopurinol prevents cardiac and skeletal muscle damage in professional soccer players.
- Author
-
Sanchis‐Gomar, F., Pareja‐Galeano, H., Gomez‐Cabrera, M. C., Candel, J., Lippi, G., Salvagno, G. L., Mann, G. E., and Viña, J.
- Subjects
HEART metabolism ,ALLOPURINOL ,ANALYSIS of variance ,ASPARTATE aminotransferase ,BIOMARKERS ,CREATINE kinase ,HEART ,ISOENZYMES ,LACTATE dehydrogenase ,LIVER ,LIPID peroxidation (Biology) ,MYOGLOBIN ,OXIDOREDUCTASES ,PLACEBOS ,PROBABILITY theory ,RESEARCH funding ,SOCCER ,STATISTICS ,URIC acid ,DATA analysis ,PROFESSIONAL athletes ,ALANINE aminotransferase ,RANDOMIZED controlled trials ,REPEATED measures design ,DATA analysis software ,SKELETAL muscle ,TROPONIN ,GAMMA-glutamyltransferase ,MANN Whitney U Test ,CHEMICAL inhibitors ,PHARMACODYNAMICS ,THERAPEUTICS - Abstract
Xanthine oxidase (XO), a free radical-generating enzyme, is involved in tissue damage produced during exhaustive exercise. Our aim was to test whether allopurinol, a powerful inhibitor of XO, may be effective in preventing exercise-induced tissue damage in soccer players. Twelve soccer players were randomized into two experimental groups. One received allopurinol, before a match of the premier Spanish Football League, and the other placebo. Allopurinol prevented the exercise-induced increase in all the markers of skeletal muscle damage analyzed: creatine kinase, lactate dehydrogenase, aspartate aminotransferase, and myoglobin. Creatine kinase-MB isoenzyme and highly sensitive troponin T, specific biomarkers of myocardial injury, increased significantly in the placebo but not in the allopurinol-treated group after the football match. We also found that the exercise-induced lipid peroxidation, as reflected by malondialdehyde measurements, was prevented after allopurinol administration. However, inhibition of XO did not prevent the increment in the activity of alanine aminotransferase found after the match. No changes in the serum gamma glutamyltransferase activity was found after the match on either the placebo and the allopurinol groups. These two enzymes were determined as biomarkers of liver injury. Allopurinol represents an effective and inexpensive pharmacological agent to prevent tissue damage in soccer players. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
4. Management of preanalytical phase for routine hematological testing: is the pneumatic tube system a source of laboratory variability or an important facility tool?
- Author
-
Lima‐Oliveira, G., Lippi, G., Salvagno, G. L., Dima, F., Brocco, G., Picheth, G., and Guidi, G. C.
- Subjects
TRANSPORTATION ,BLOOD testing ,BLOOD collection ,BLOOD sedimentation ,BLOOD cell count ,COMPARATIVE studies ,PROBABILITY theory ,STATISTICS ,T-test (Statistics) ,DATA analysis ,EVALUATION research ,DESCRIPTIVE statistics - Abstract
A letter to the editor is presented on a study conducted to evaluate the impact of pneumatic tube system (PTS) for routine hematological testing.
- Published
- 2014
- Full Text
- View/download PDF
5. Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.
- Author
-
LIMA-OLIVEIRA, G., LIPPI, G., SALVAGNO, G. L., MONTAGNANA, M., SCARTEZINI, M., GUIDI, G. C., and PICHETH, G.
- Subjects
VENOUS puncture ,BLOOD testing ,COMPARATIVE studies ,LIGHT ,PROBABILITY theory ,INDUSTRIAL research ,STATISTICS ,T-test (Statistics) ,TOURNIQUETS ,DATA analysis ,EQUIPMENT & supplies - Abstract
Summary Introduction: The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in patients with difficult or small veins, such as children. This study was aimed to evaluate whether a transillumination device can advantageously replace the use of the tourniquet during the procedure for collection of blood specimens for RHT and thereby eliminating the discomfort and risk of spurious results caused by excessive or prolonged venous stasis. Methods: Two hundred and fifty volunteers were divided into five groups (G1, G2, G3, G4 and G5) to compare the results of RHT between blood sample collected with transilluminator device (left arm) and with tourniquet application (right arm) for 30 s(G1), 60 s(G2), 90 s(G3), 120 s(G4) and 180 s(G5). Results: No significant increases were observed in any of the haematological parameters tested in G1 when compared with blood collected by the transilluminator device. From G2 to G5, significant increases were observed for the platelet count, red blood cell count, haemoglobin, haematocrit, white blood cell count, neutrophils, monocytes and eosinophils. From G3-G5, further increases were observed for lymphocytes. Clinically significant variations were, however, observed for basophils in G2; red blood cell count, haemoglobin, haematocrit and basophils in G3 and eosinophils in G3 only. Conclusion: As such, considering that inappropriate use of the tourniquet is commonplace, we conclude that transillumination devices can represent a suitable tool to eliminate the venous stasis and to improve the quality of phlebotomy procedures. [ABSTRACT FROM AUTHOR]
- Published
- 2011
- Full Text
- View/download PDF
6. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample.
- Author
-
LIPPI, G., SALVAGNO, G. L., ADCOCK, D. M., GELATI, M., GUIDI, G. C., and FAVALORO, E. J.
- Subjects
- *
BLOOD coagulation , *BLOOD collection , *ALIQUOT sequences , *ELECTROLYTES , *BLOOD plasma - Abstract
Inappropriate blood collection potentially comprises the major pre-analytical problem for coagulation testing. Inappropriate samples are most difficult to detect when received as secondary aliquots, common for referred tests. This study aimed to identify a simple, quick and inexpensive process to help laboratories distinguish the type of sample, should there be suspicion of inappropriate collection. Samples from 15 patients [selected on the basis that four different primary tubes were available: serum, citrated plasma, ethylene diamine tetraacetic acid (EDTA) plasma, lithium-heparin plasma], were tested for common electrolytes that might substantially differ according to the type of sample. In citrated plasma, potassium, chloride, calcium and magnesium were significantly decreased compared with serum and lithium-heparin plasma, while sodium was markedly increased. In EDTA plasma, sodium and chloride were significantly decreased compared with both serum and lithium-heparin plasma, potassium was always >14 mmol/l, whereas magnesium and calcium were virtually undetectable. These data allowed development of two algorithms for differential identification of citrated plasma vs. other samples with 100% sensitivity and specificity, the former based on the sequential measurement of potassium, calcium and sodium, the latter on potassium and sodium. These simple assays can supplement classical coagulation test methods to identify most inappropriate blood collections and validate sample rejection. [ABSTRACT FROM AUTHOR]
- Published
- 2010
- Full Text
- View/download PDF
7. Acute variation of leucocytes counts following a half-marathon run.
- Author
-
LIPPI, G., BANFI, G., MONTAGNANA, M., SALVAGNO, G. L., SCHENA, F., and GUIDI, GIAN CESARE
- Subjects
LEUCOCYTES ,HALF marathons (Running) ,BLOOD cells ,BLOOD platelets ,MONOCYTOSIS - Abstract
There is growing interest on haematological changes following elite and recreation sports. However, no information is available on leucocyte variations after an intermediate-distance run. Complete blood cell count was assessed on 17 trained, middle-aged males before a 21-km half-marathon, at the end and 3, 6, 24 h thereafter. Statistically significant variations by one-way analysis of variance were observed for all the parameters tested. Haematocrit, haemoglobin and red blood cells and platelet count increased significantly by the end of the run and returned to pre-run values 3 h thereafter. White blood cells, neutrophils, monocytes and basophils counts increased after the run, reached the peak at 3 h and returned to the baseline after 24 h. Conversely, the eosinophils count significantly decreased after the run, reached a nadir at 3 h and slowly returned to pre-run values at 24 h. The lymphocytes count significantly increased after the run, decreased 3 h thereafter and returned to pre-run values after 6 h. These results show that an intermediate-distance run, which is a popular form of recreational sports worldwide, is associated with transitory leucocytosis, neutrophilia, monocytosis and basophilia, but it also induces acute eosinopenia, all changes being completely reversed 24 h thereafter. [ABSTRACT FROM AUTHOR]
- Published
- 2010
- Full Text
- View/download PDF
8. Influence of temperature and time before centrifugation of specimens for routine coagulation testing.
- Author
-
Salvagno, G. L., Lippi, G., Montagnana, M., Franchini, M., Poli, G., and Guidi, G. C.
- Subjects
- *
THROMBOPLASTIN , *FIBRINOGEN , *BLOOD testing , *ANTIVITAMINS , *TEMPERATURE , *CENTRIFUGATION , *THERAPEUTICS - Abstract
The accurate standardization of the preanalytical phase is of pivotal importance for achieving reliable results of coagulation tests. Because information on the suitable storage conditions for coagulation testing is controversial, we aimed at investigating the sample stability with regard to the temperature and time before centrifugation. The activated partial thromboplastin time (aPTT), prothrombin time (PT), fibrinogen and D-dimer were assayed in specimens collected from 26 consecutive patients on antivitamin K therapy on the ACL TOP analyzer. Three primary 3.6-ml siliconized evacuated tubes containing 0.109 mol/l buffered trisodium citrate were sequentially collected from each patient. These three tubes were mixed, pooled and divided into seven identical aliquots. The first aliquot was immediately centrifuged according to the standard protocol [1500 g for 15 min at room temperature (RT)] and analyzed. The other aliquots were left for 3, 6 and 24 h, respectively, at RT or 4 °C, and then centrifuged and analyzed. Test results were compared with those obtained on the reference specimen. Statistically significant prolongations were observed for aPTT in all the samples. Such differences exceeded the analytical quality specifications for desirable bias in the samples stored for 24 h. A significant reduction, yet comprised within the desirable bias, was observed for PT and fibrinogen in uncentrifuged specimens stored at RT for 3 and 6 h. No significant biases could be recorded in D-dimer. In conclusion, a 6-h storage of uncentrifuged specimens at either RT or 4 °C may still be suitable to achieve results of routine coagulation testing comprised within the analytical quality specifications for desirable bias. [ABSTRACT FROM AUTHOR]
- Published
- 2009
- Full Text
- View/download PDF
9. Thrombin generation assay: a useful routine check-up tool in the management of patients with haemophilia?
- Author
-
SALVAGNO, G. L., ASTERMARK, J., LIPPI, G., EKMAN, M., FRANCHINI, M., GUIDI, G. C., and BERNTORP, E.
- Subjects
- *
HEMOPHILIA , *BLOOD coagulation disorders , *BLOOD coagulation factors , *PATIENTS , *THROMBIN - Abstract
Severity assessment of patients with haemophilia A (HA) is traditionally based on FVIII activity (FVIII:C). Clinical phenotype of HA patients often differs between individuals with the same FVIII:C determined with clotting and chromogenic assays. The aim of this study was to assess the influence of the FVIII:C on thrombin generation (TG) assay parameters both in vitro and ex-vivo postinfusion plasma. For in-vitro approach, influence of FVIII:C was evaluated on TG parameters in several dilutions of a normal plasma pool with commercial FVIII-depleted-plasma (FVIIIDP) and in others experiments, adding increasing amounts of different commercial FVIII concentrates (Fanhdi, Haemate-P, Hemofil-M and Kogenate Bayer) to FVIIIDP. In a series of 50 postinfusion samples, from HA patients of different severity, we assayed TG and FVIII:C (chromogenic and clotting). In vitro experiments, the 50% of maximum TG peak (TGMP) was achieved using only 5% FVIII:C and the TGMP was obtained with 40% of normal VIII:C. Impaired response compared with normal plasma was found in FVIIIDP using addition of increasing amounts of different commercial FVIII concentrates. An overall good correlation between the two FVIII assays was observed ( y = 0.9115x − 0.273, r = 0.975, P < 0.001); TGMP and the Lag-Phase-Time (LPT) provided some discrepant results when compared with the total range of FVIII:C measurements. In contrast, correlations for TGMP, LPT and endogenous thrombin potential were improved in samples restricted to FVIII:C <5%. We conclude that TG parameters tentatively could be a tool to tailor the global haemostatic capacity in haemophilic patients. [ABSTRACT FROM AUTHOR]
- Published
- 2009
- Full Text
- View/download PDF
10. Separation of haemoglobin HbE and HbA2 by the fully automated, high-pressure liquid chromatography Tosoh HLC-723 G7 analyzer.
- Author
-
LIPPI, G., CARTA, M. R., SALVAGNO, G. L., BELLORIO, F., MONTAGNANA, M., SOFFIATI, G., and GUIDI, G. C.
- Subjects
HIGH performance liquid chromatography ,HEMOGLOBINS ,BLOOD pigments ,BLOOD proteins ,HIGH pressure (Science) ,HEMATOLOGY - Abstract
High-pressure liquid chromatography instruments specifically devised for separating haemoglobin (Hb) fractions have been increasingly employed by the hospital laboratories over the recent years since they allow easy and fast screening for several Hb variants. Although such instruments may be proposed as sensitive, specific and reliable alternatives to the classic electrophoretic techniques, a major drawback of this screening strategy is the almost identical retention time of several Hb variants. In particular, at least 18 Hb variants have been reported in the same retention window as HbA
2 , including HbE, the second most common β-chain variant in humans after sickle cell trait. Recently, we evaluated the performance characteristics of an improved buffer formulation originally conceived for Hb variants separation procedures on the fully automated high-pressure liquid chromatography instrument Tosoh G7. At variance with other fully automated high-pressure liquid chromatography analyzers, the elution pattern on the G7 in subjects heterozygous for HbE is characterized by the presence of four suggestive peaks (HbF, HbA, HbA2 and HbE), confirming the effective separation of HbE from HbA2 . Because of its potential value in the diagnosis of the thalassaemia syndromes, the effective separation of HbA2 from HbE can provide clinical laboratories with a valuable information for the diagnostic reasoning. [ABSTRACT FROM AUTHOR]- Published
- 2008
- Full Text
- View/download PDF
11. Immune tolerance with rituximab in congenital haemophilia with inhibitors: a systematic literature review based on individual patients’ analysis.
- Author
-
FRANCHINI, M., MENGOLI, C., LIPPI, G., TARGHER, G., MONTAGNANA, M., SALVAGNO, G. L., ZAFFANELLO, M., and CRUCIANI, M.
- Subjects
IMMUNOLOGICAL tolerance ,RITUXIMAB ,GENETIC disorders ,HEMOPHILIA ,HEMOPHILIACS - Abstract
Rituximab, a monoclonal antibody against the pan B-cell antigen CD20, has been successfully used in both adults and children for the management of malignant and non-malignant immune-mediated disorders including acquired haemophilia. On the basis of this positive experience, a number of investigators have recently used this agent in patients with congenital haemophilia and inhibitors refractory to first-line treatments. After a careful electronic and hand search, we have collected 29 studies that included 49 cases. A durable complete remission was obtained in 53% of the cases and no severe adverse events related to rituximab were recorded. A multivariate analysis applied to individual patients’ data identified the diagnosis of a mild/moderate haemophilia and the concomitant treatment with factor VIII concentrates and immunosuppression agents as covariates associated with an increased response to rituximab. Large prospective randomized studies with an adequate follow-up are needed to confirm these preliminary findings. [ABSTRACT FROM AUTHOR]
- Published
- 2008
- Full Text
- View/download PDF
12. Analytical performances of thed-dimer assay for the Immulite 2000 automated immunoassay analyser.
- Author
-
LIPPI, G., SALVAGNO, G. L., ROSSI, L., MONTAGNANA, M., FRANCHINI, M., and GUIDI, G. C.
- Subjects
- *
IMMUNOASSAY , *ANALYSIS of variance , *BLOOD proteins , *MULTIVARIATE analysis , *PATHOLOGICAL laboratories , *REGRESSION analysis - Abstract
We evaluated the analytical performances of a new commercial chemiluminescent enzyme immunometric assay ford-dimer measurement on the Immulite 2000 automated analyser. The within- and between-run coefficients of variations for low, intermediate and highd-dimer concentrations ranged from 2.2% to 5.1% and from 2.9% to 6.0% respectively. The assay was proven linear in a range ofd-dimer concentrations comprised between 324 and 7602 ng/ml. Comparison of samples collected in either 0.109 mol/l sodium citrate or lithium–heparin tubes by Bland–Altman plots and nonparametric regression analysis ( y = 0.858 x − 39, r = 0.997; P < 0.0001) revealed a minimum bias, almost completely attributable to the dilution effect of the anticoagulant. Results of 56 outpatients’ citrated plasma samples analysed with the Immulite 2000d-dimer assay were compared with those of the current reference commercial immunoassay on the Mini Vidas Immunoanalyser. Although the nonparametric regression according to the method of Passing and Bablok and the relative Spearman's correlation coefficient was satisfactory (Immulite = 1.001 × Vidas − 181; r = 0.937, P < 0.001), some random discrepancies could be observed in Bland–Altman plots analysis. The analytical accuracy, calculated as the area under the Receiver Operating Characteristic (ROC) curve (AUC), was 0.961 ( P < 0.0001). On the basis of the results of the present evaluation, we conclude that the analytical performances and the main technical features of new Immulite 2000d-dimer assay make it a suitable method for the rapid quantification ofd-dimer in clinical laboratories. [ABSTRACT FROM AUTHOR]
- Published
- 2007
- Full Text
- View/download PDF
13. Impact of different inhibitor reactivities with commercial factor VIII concentrates on thrombin generation.
- Author
-
SALVAGNO, G. L., ASTERMARK, J., EKMAN, M., FRANCHINI, M., GUIDI, G. C., LIPPI, G., POLI, G., and BERNTORP, E.
- Subjects
- *
BLOOD coagulation factor VIII , *HEMOPHILIA , *CHEMICAL inhibitors , *VON Willebrand factor ,THROMBIN synthesis - Abstract
In order to describe the haemostatic role of a variation in inhibitor reactivity with different factor VIII (FVIII) concentrates, we have compared inhibitor titres against a panel of FVIII concentrates and correlated titre with the capacity to inhibit thrombin generation. Three plasma-derived concentrates were tested in vitro in mixing experiments with inhibitor plasmas from 11 patients with severe haemophilia A: Fanhdi, which contains von Willebrand factor (VWF) with a final ratio of approximately 1:1 (VWF IU per IU FVIII:C); Haemate-P with a ratio of 2.5:1 and Hemofil-M containing only trace amounts of VWF. In addition, the recombinant FVIII concentrate Kogenate Bayer containing no VWF was included. Inhibitor titres and the capacity to generate thrombin were measured. A statistically significant difference in measured titres was found with the highest titres recorded against Hemofil-M. The inhibitor titres needed to inhibit 50% maximum thrombin generation were the lowest for Kogenate Bayer and the highest and similar for Fanhdi and Haemate-P with intermediate titres needed for inhibition of Hemofil-M. In this study, the thrombin generation assay provides additional indications for the role of VWF in the treatment of patients with inhibitors. The VWF-containing concentrates Fanhdi and Haemate-P, added to FVIII-deficient plasma with the presence of inhibitor, generate more thrombin than do the purified concentrates Hemofil-M and Kogenate Bayer. [ABSTRACT FROM AUTHOR]
- Published
- 2007
- Full Text
- View/download PDF
14. Venous stasis and routine hematologic testing.
- Author
-
Lippi, G., Salvagno, G. L., Montagnana, M., Franchini, M., and Guidi, G. C.
- Subjects
- *
PULMONARY veins , *HEMATOLOGY , *ERYTHROCYTES , *HEMOGLOBINS , *BLOOD platelets , *LEUCOCYTES , *DISEASES - Abstract
Prolonged venous stasis, as generated by a long tourniquet placement, produces spurious variations in several measurable analytes. To verify to what extent venous stasis influences routine hematologic testing, we assessed routine hematologic parameters, including hemoglobin, hematocrit, red blood cell count (RBC), main cell hemoglobin (MHC), main cell volume (MCV), platelet count (PLT), main platelet volume (MPV), white blood cell count (WBC) and WBC differential on the Advia 120 automated hematology analyzer in 30 healthy volunteers, either without venous stasis (no stasis) or after application of a 60 mmHg standardized external pressure by a sphygmomanometer, for 1 (1-min stasis) and 3 min (3-min stasis). Although the overall correlation between measures was globally acceptable, the mean values for paired samples were significantly different in all parameters tested, except MCV, MHC, PLT, MPV, eosinophils, basophils and large unstained cells after 1-min stasis and all parameters except MCV, MHC, MPV and basophils after 3-min venous stasis. As expected RBC, hemoglobin and hematocrit displayed a significant trend towards increase, whereas WBC and the WBC subpopulations were decreased. Difference between measurements by Bland and Altman plots exceeded the current analytical quality specifications for desirable bias for WBC, RBC, hemoglobin, hematocrit, lymphocytes and monocytes in samples collected after either 1- and 3-min stasis. These results provide clear evidence that venous stasis during venipuncture might produce spurious and clinically meaningful biases in the measurement of several hematologic parameters, prompting further considerations on the usefulness of adopting appropriate preventive measures for minimizing such influences. [ABSTRACT FROM AUTHOR]
- Published
- 2006
- Full Text
- View/download PDF
15. Tyr2105Cys mutation in exon 22 of FVIII gene is a risk factor for the development of inhibitors in patients with mild/moderate haemophilia A.
- Author
-
Franchini, M., Girelli, D., Olivieri, O., Castaman, G., Lippi, G., Poli, G., Salvagno, G. L., Tagariello, G., Giuffrida, A., De Gironcoli, M., Morfini, M., Berntorp, E., and Gandini, G.
- Subjects
HEMOPHILIA ,BLOOD diseases ,BLOOD coagulation disorders ,HEMORRHAGE ,ANEMIA - Abstract
We report the case of a patient with mild haemophilia A, due to a Tyr2105Cys mutation in exon 22 of the C1 domain, who developed a high-titre factor VIII inhibitor (maximum titre 1600 BU) with recurrent severe haemorrhages and fatal intracranial bleeding. Based on published data, it appears that although this mutation occurs rarely in patients with mild or moderate haemophilia A, it is frequently associated with the development of high-titre inhibitors. [ABSTRACT FROM AUTHOR]
- Published
- 2006
- Full Text
- View/download PDF
16. Analytical comparison of AxSYM, HemosIL DD HS and Innovance D-dimer immunoassays with the Vidas D-dimer.
- Author
-
Salvagno, G. L., Lippi, G., Manzato, F., Giavarina, D., Montagnana, M., Poli, G., and Guidi, G. C.
- Subjects
- *
LETTERS to the editor , *IMMUNOASSAY - Abstract
A letter to the editor is presented in response to the article "Analytical comparison of AxSYM, HemosIL DD HS and Innovance ᴅ-dimer Immunoassays With the Vidas ᴅ-dimer," by G. L. Salvagno and colleagues.
- Published
- 2009
- Full Text
- View/download PDF
17. The red blood cell distribution width is associated with serum levels of thyroid stimulating hormone in the general population.
- Author
-
MONTAGNANA, M., LIPPI, G., TARGHER, G., SALVAGNO, G. L., and GUIDI, G. C.
- Subjects
LETTERS to the editor ,ERYTHROCYTES - Abstract
A letter to the editor is presented analyzing the linkage between red blood cell distribution width and serum levels of thyroid stimulating hormone.
- Published
- 2009
- Full Text
- View/download PDF
18. Acute influence of aerobic physical exercise on procalcitonin.
- Author
-
Lippi, G., Schena, F., Montagnana, M., Salvagno, G. L., and Guidi, G. C.
- Subjects
AEROBIC exercises ,ATHLETES ,MARATHON running ,SPORTS medicine ,ANALYSIS of variance - Abstract
The article discusses an investigation of the metabolism of procalcitonin (PCT) in male athletes during aerobic physical exercise. A one-way analysis of variance revealed an increase of PCT values over the pre-run values after the half-marathon run, which continued to rise six hours and 24 hours after the run. It is concluded that a subintensive aerobic activity has an acute influence on the PCT levels of healthy, middle-aged trained individuals.
- Published
- 2008
- Full Text
- View/download PDF
19. Relationship between lipoprotein(a) and fasting plasma glucose in the general population.
- Author
-
Lippi, G., Targher, G., Salvagno, G. L., Montagnana, M., and Guidi, G. C.
- Subjects
MEDICAL research ,LIPOPROTEIN A ,GLUCOSE ,CARDIOVASCULAR diseases ,BIOCHEMISTRY - Abstract
The article discusses a research on the relationship between lipoprotein(a) and glucose metabolism in the general population. The study indicates that lipoprotein(a) is a cholesterol-based particle which is one of the factors that causes cardiovascular diseases. Furthermore, an analysis done by the University Hospital of Verona suggests that lipoprotein(a) and glucose tolerance are very much different.
- Published
- 2007
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.