1. Successful use of flexible silicone mesh for management of prolonged open abdomen
- Author
-
Ryosuke Tsutsumi, Tomohiko Akahoshi, Tetsuo Ikeda, Yoshihiko Maehara, and Makoto Hashizume
- Subjects
Fascial closure ,open abdomen management ,sepsis ,silicone mesh ,Medical emergencies. Critical care. Intensive care. First aid ,RC86-88.9 - Abstract
Background Open abdomen management (OAM) is used not only for trauma but also for treatment of peritonitis. However, the rate of successful fascial closure in patients with OAM remains low. Case Presentation The patient was a 38‐year‐old morbidly obese man who underwent laparoscopic sleeve gastrectomy. Twenty days after surgery, postoperative leakage resulted in panperitonitis. In this case, we undertook drainage by open laparotomy. The patient's status was generally unstable and he was treated with OAM. We used flexible silicone mesh as the dressing material for negative‐pressure wound therapy. Open abdominal management continued until status improvement (32 days). Fascial closure was eventually successful because of good granulation growth. Conclusion When combined with negative‐pressure wound therapy, silicone mesh prevents wound adhesions and infection after surgery. Silicone mesh is useful for patients with increased risk of infection, such as those with diffuse peritonitis.