1. Characterization of the analytical performance of δ 15 N and δ 18 O measurements by the silver nitrate method in the framework of nitrate source apportioning
- Author
-
Luisa Stellato, Brunella Di Rienzo, Fabio Marzaioli, Mauro Rubino, Egidio Di Fusco, Antonio D'Onofrio, Filippo Terrasi, Marzaioli, Fabio, Di Rienzo, Brunella, Stellato, Luisa, Di Fusco, Egidio, Rubino, Mauro, D'Onofrio, Antonio, and Terrasi, Filippo
- Subjects
Normalization (statistics) ,Reproducibility ,Accuracy and precision ,010401 analytical chemistry ,Organic Chemistry ,Analytical chemistry ,Contamination ,01 natural sciences ,Standard deviation ,0104 chemical sciences ,Analytical Chemistry ,chemistry.chemical_compound ,Isotope fractionation ,Nitrate ,chemistry ,Isotope-ratio mass spectrometry ,Spectroscopy - Abstract
Rationale Nitrate pollution represents one of the most important issues for ground and surface water quality and source identification is essential for developing effective mitigation practices. Nitrate isotopic fingerprinting can be utilized to identify the sources of nitrate pollution in aquifers. However, it is crucial to assess the performances (precision and accuracy) of the analytical procedure applied to measure the δ15 N and δ18 O values of nitrates from field samples to correctly apply this tool. Methods Nitrates were extracted from a large number of KNO3 samples using the AgNO3 method, and the δ15 N and δ18 O values of these nitrate extracts were measured by isotope ratio mass spectrometry. The availability of this dataset, comprising 693 unprocessed quality control (QC) KNO3 samples and 618 processed samples, allowed us to rigorously quantify the performance of the procedures employed. A salt doping experiment was also performed from which the effects of contaminants on the performance of the method could be ascertained. Results The overall instrumental reproducibility for the analysis of unprocessed QC samples was 0.5‰ and 2‰ for δ15 N and δ18 O values, respectively, and a strict dependence on signal amplitude was observed. No isotope fractionation was reported for reference samples that were processed according to the "identical treatment" principle (ITP) but normalized by unprocessed reference materials. A significant increase in the standard deviation (SD) was, however, observed compared with that for unprocessed samples. The SD of the processed QC samples allowed us to quantify the reproducibility of the entire procedure as 0.6‰ and 1.0‰ for δ15 N and δ18 O values, respectively. This was comparable with the system reproducibility when normalization using processed reference materials was applied according to the ITP. Conclusions Normalization with processed standards is essential to achieve high-precision measurements of the δ15 N and δ18 O values of nitrates extracted from unknown samples. This procedure allowed good accuracy to be guaranteed, and precision levels comparable with the observed instrumental performance to be achieved. A salt doping experiment showed a significant influence of the SO4 2- content on the δ15 N values.
- Published
- 2020
- Full Text
- View/download PDF