1. Fenestration closure with Amplatzer Duct Occluder II in patients after total cavo-pulmonary connection
- Author
-
Paweł Dryżek, Sebastian Góreczny, Jadwiga Moll, Tomasz Moszura, Shakeel A. Qureshi, Gareth J. Morgan, Anna Mazurek-Kula, and Jacek Moll
- Subjects
medicine.medical_specialty ,Percutaneous ,Population ,lcsh:Medicine ,030204 cardiovascular system & hematology ,03 medical and health sciences ,0302 clinical medicine ,Clinical Research ,Residual flow ,Internal medicine ,new devices ,Occlusion ,percutaneous intervention ,medicine ,In patient ,030212 general & internal medicine ,education ,education.field_of_study ,business.industry ,lcsh:R ,General Medicine ,Color doppler ,medicine.disease ,congenital heart disease ,Surgery ,Heart failure ,Cardiology ,business ,Fenestration - Abstract
Introduction : Creation of a fenestration during completion of a total cavo-pulmonary connection (TCPC) has been associated with a reduction in early mortality and morbidity. However, the long-term benefits are negated by an associated limitation in exercise tolerance and the potential risks of thrombo-embolic complications. We sought to describe the safety and efficacy of an Amplatzer Duct Occluder II (ADO II) for transcatheter fenestration closure following TCPC. Material and methods : Between January 2000 and July 2014, 102 patients underwent percutaneous closure of extra-cardiac TCPC fenestrations with a range of devices. Patients in whom fenestration closure was performed with an ADO II and who had at least 6 months of follow-up were included in this study. Results : Forty-seven patients had successful fenestration occlusion with an ADO II. The mean oxygen saturation and mean systemic venous pressures increased from 84.8 ±6.1% before to 97.6 ±2.9% (p < 0.001) after and from 14.2 ±2.15 mm Hg before to 15.6 ±2.2 mm Hg after closure (p < 0.001). Eight patients developed heart failure symptoms, managed by optimization of medical therapy, with 1 patient requiring device removal to reopen the fenestration. Color Doppler transthoracic echocardiography demonstrated residual flow across the device in 18 (38%), 10 (22%), 5 (11%) and 4 (9%) patients before discharge, at 1 and 6 months, and at the latest outpatient visit, respectively. Conclusions : The ADO II can be safely and effectively used to close fenestrations in extra-cardiac type Fontan completions. Many of the design features of this device confer potential benefit in this population.
- Published
- 2017
- Full Text
- View/download PDF