1. [Stapes surgery for otosclerosis using a new titanium prosthesis with a superelastic nitinol clip: First experiences].
- Author
-
Zirkler J, Rahne T, and Plontke SK
- Subjects
- Adult, Alloys, Elastic Modulus, Equipment Failure Analysis, Female, Hearing Loss, Conductive diagnosis, Humans, Male, Middle Aged, Ossicular Replacement instrumentation, Ossicular Replacement methods, Otosclerosis diagnosis, Pilot Projects, Prosthesis Design, Retrospective Studies, Stapes Surgery methods, Titanium, Treatment Outcome, Hearing Loss, Conductive surgery, Ossicular Prosthesis, Otosclerosis surgery, Stapes Surgery instrumentation, Surgical Instruments
- Abstract
Background: Coupling of the prosthesis to the long process of the incus is a critical step in stapes surgery. We report first experiences with the NiTiFLEX® stapes prosthesis, a further development of the Soft CliP® stapes prosthesis (Kurz, Dusslingen, Germany). Instead of pure titanium, the CliP® now consists of nitinol, a superelastic nickel-titanium alloy. This further reduces the pressure exerted on the long process of the incus, aiming to improve coupling and minimize the risk of incus luxation., Methods: In a monocentric, retrospective cohort study, we evaluated air-bone gap reduction (4PTA0.5-4 kHz), understanding of monosyllables at 65 and 80 dB SPL stimulation levels, and adverse effects, such as changes in bone conduction (4PTA0.5-4 kHz). During a 12-month period (May 2014 to April 2015), stapes surgery was performed in 21 otosclerosis patients using the NiTiFLEX® prosthesis. The footplate was perforated using a CO2 laser (scanning mode; 0.7 mm; 20-21 W) in almost all cases. The diameter of the titan piston was 0.4 mm. Immersion at an angle of almost 90° thus results in a gap between the footplate perforation and the piston of 0.15 mm. Positioning onto the long incus process was performed with a 90°microhook (0.6 mm)., Results: In all cases the NiTiFLEX® stapes prosthesis was inserted without complications. The mean bone conduction threshold did not change significantly postoperatively and the mean air-bone gap (4PTA0.5-4 kHz) improved on average from 29.0 to 9.5 dB HL. Handling of the prosthesis was rated as very good., Conclusion: The limited experience of this study suggests that the NiTiFLEX® stapes prosthesis is a successful further development of the Soft CliP® technique with very good intraoperative handling qualities. While long-term results from larger studies are needed, this case series demonstrates that the hearing outcome is comparable to other prostheses.
- Published
- 2016
- Full Text
- View/download PDF