1. Utility of the transcranial doppler in the evaluation and follow-up of children with Sturge-Weber Syndrome.
- Author
-
Jiménez-Legido M, Martínez-de-Azagra-Garde A, Bernardino-Cuesta B, Solís-Muñiz I, Soto-Insuga V, Cantarín-Extremera V, García-Salido A, Duat-Rodríguez A, García-Peñas JJ, and Ruíz-Falcó-Rojas ML
- Subjects
- Brain physiopathology, Child, Child, Preschool, Disease Progression, Female, Follow-Up Studies, Humans, Infant, Male, Sturge-Weber Syndrome physiopathology, Brain blood supply, Brain diagnostic imaging, Sturge-Weber Syndrome diagnostic imaging, Ultrasonography, Doppler, Transcranial methods
- Abstract
Introduction: Sturge-Weber syndrome (SWS) is a neurocutaneous syndrome with typical clinical features including seizures, chronic hemiplegia, hemianopsia and intellectual impairment. Progressive clinical decline may be attributable, at least in part, to progressive venous ischemia. Transcranial Doppler (TCD) ultrasonography could be useful to monitor the degree of hemodynamic involvement and its progression., Purpose: To determine whether there is an association between the degree of asymmetry in TCD and intensity of clinical and radiological involvement and whether there is a correlation between clinical changes and changes in serial TCD., Methods: In fourteen SWS pediatric patients and two "possible cases" (infants younger than two years old without previously known brain involvement, but with other typical signs of SWS) mean flow velocity in the middle cerebral arteries (MCA) was measured by TCD in both hemispheres. The percent difference between hemispheres (asymmetry) was calculated. Clinical and radiological severity was scored using scales. The correlation between TCD asymmetry and SWS clinical and radiological scores was analyzed at baseline, as well as the correlation between the changes in the different variables (TCD asymmetry, clinical and radiological cores) during evolution and in relation to the changes due to therapy., Results: The percentage of MCA velocity asymmetry was positively correlated with the clinical severity score (p = 0.04), and with seizure frequency (p = 0.014). Throughout evolution, therapeutic and clinical changes were associated with noticeable changes in transcranial doppler asymmetry in some cases., Conclusions: TCD may provide a noninvasive method to assess the severity of blood flow abnormalities at baseline and a method to monitor children for progressive changes over time., Competing Interests: Declaration of competing interest None., (Copyright © 2020 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF