1. Dose Reduction and Low-Contrast Detectability Using Iterative CBCT Reconstruction Algorithm for Radiotherapy
- Author
-
Hayate Washio, Shingo Ohira, Yoshinori Funama, Yoshihiro Ueda, Masahiro Morimoto, Naoyuki Kanayama, Masaru Isono, Shoki Inui, Yuya Nitta, Masayoshi Miyazaki, and Teruki Teshima
- Subjects
Cancer Research ,Anthropometry ,Phantoms, Imaging ,Radiotherapy Planning, Computer-Assisted ,low-contrast detectability ,Contrast Media ,Neoplasms. Tumors. Oncology. Including cancer and carcinogens ,Radiotherapy Dosage ,Cone-Beam Computed Tomography ,Signal-To-Noise Ratio ,iterative CBCT ,Pelvis ,dose reduction ,Oncology ,Image Processing, Computer-Assisted ,Humans ,Original Article ,registration error ,radiotherapy ,Biomarkers ,RC254-282 ,Radiotherapy, Image-Guided - Abstract
Introduction: Several studies have reported the relation between the imaging dose and secondary cancer risk and have emphasized the need to minimize the additional imaging dose as low as reasonably achievable. The iterative cone-beam computed tomography (iCBCT) algorithm can improve the image quality by utilizing scatter correction and statistical reconstruction. We investigate the use of a novel iCBCT reconstruction algorithm to reduce the patient dose while maintaining low-contrast detectability and registration accuracy. Methods: Catphan and anthropomorphic phantoms were analyzed. All CBCT images were acquired with varying dose levels and reconstructed with a Feldkamp–Davis–Kress algorithm-based CBCT (FDK-CBCT) and iCBCT. The low-contrast detectability was subjectively assessed using a 9-point scale by 4 reviewers and objectively assessed using structure similarity index (SSIM). The soft tissue-based registration error was analyzed for each dose level and reconstruction technique. Results: The results of subjective low-contrast detectability found that the iCBCT acquired at two-thirds of a dose was superior to the FDK-CBCT acquired at a full dose (6.4 vs 5.4). Relative to FDK-CBCT acquired at full dose, SSIM was higher for iCBCT acquired at one-sixth dose in head and head and neck region while equivalent with iCBCT acquired at two-thirds dose in pelvis region. The soft tissue-based registration was 2.2 and 0.6 mm for FDK-CBCT and iCBCT, respectively. Conclusion: Use of iCBCT reconstruction algorithm can generally reduce the patient dose by approximately two-thirds compared to conventional reconstruction methods while maintaining low-contrast detectability and accuracy of registration.
- Published
- 2022