1. Cardiac troponin release following hybrid coronary revascularization versus off-pump coronary artery bypass surgery.
- Author
-
Harskamp RE, Abdelsalam M, Lopes RD, Boga G, Hirji S, Krishnan M, Kiljanek L, Mumtaz M, Tijssen JG, McCarty C, de Winter RJ, and Bachinsky WB
- Subjects
- Aged, Biomarkers blood, Chi-Square Distribution, Coronary Artery Bypass, Off-Pump mortality, Coronary Artery Disease blood, Coronary Artery Disease diagnosis, Coronary Artery Disease mortality, Coronary Artery Disease surgery, Female, Humans, Linear Models, Male, Middle Aged, Multivariate Analysis, Myocardial Infarction blood, Myocardial Infarction etiology, Percutaneous Coronary Intervention mortality, Registries, Retrospective Studies, Risk Factors, Time Factors, Treatment Outcome, Coronary Artery Bypass, Off-Pump adverse effects, Coronary Artery Disease therapy, Percutaneous Coronary Intervention adverse effects, Troponin I blood
- Abstract
Objectives: Cardiac ischaemic marker release is associated with adverse clinical outcomes after cardiac surgery. We sought to compare the release of cardiac troponin I (cTnI) after hybrid coronary revascularization (HCR) with off-pump coronary artery bypass surgery (OPCAB)., Methods: Using data from a prospective single-centre registry, we compared cTnI measured at postoperative day 1 following one-stage HCR and OPCAB among patients with normal baseline cTnI. Multivariable linear regression analysis was used to adjust for variables that may have influenced cardiac marker release other than the used revascularization strategy., Results: Sixty-five consecutive patients underwent elective HCR (n = 33) or OPCAB (n = 32). Overall, no differences were seen in comorbidities, CABG risk scores and the lesion-specific SYNTAX score. Procedural complications were lower (15.2 vs 34.4%, P = 0.072), but 30-day and 1-year clinical outcomes (death, myocardial infarction, and repeat revascularization) were similar between the two groups (3.0 vs 3.1% and 9.1 vs 6.2%, respectively). Post-procedural cTnI release measured at 24 h after surgery was significantly lower following HCR compared with OPCAB [ratio of upper reference level URL: median: 3.5, interquartile range (IQR): 0.8-9.1 vs 12.8, IQR: 6.9-21.8, P = 0.001]. After adjusting for potential confounders, HCR was associated, on average, with cTnI less than half (46%) compared with CABG (P <0.0001)., Conclusions: HCR is associated with lower postoperative cTn release, compared with OPCAB. Further research into the clinical implications of this finding is warranted., (© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF