1. Flow Cytometry Coupled with Resuscitation Assays As a High-Resolution Tool to Inform Environmental Management and Disinfection of Settings Affected by Tuberculous Mycobacteria.
- Author
-
Pereira, André C. and Cunha, Mónica V.
- Subjects
FLOW cytometry ,ENVIRONMENTAL management ,BACTERIAL inactivation ,TUBERCULOSIS ,MYCOBACTERIA ,DISINFECTION & disinfectants - Abstract
Environmental decontamination and water disinfection practices are hallmarks of disease prevention and control in agricultural and public health settings. Informed fit-to-purpose biocontainment is thus dependent on methodologies accurately assessing microbial burden and viability. Also, rigorous evaluation of the efficacy of biocontrol measures implies monitoring microbial inactivation after decontamination/disinfection procedures. In this study, we used flow cytometry coupled with a resuscitation protocol to monitor the metabolic inactivation of bacteria capable of entering non-cultivable states, after the application of a chlorine-based water disinfectant. For this purpose, we used Mycobacterium bovis BCG as a model of slow-growing bacteria able to enter dormancy and representing a multi-host pathogen in a zoonotic disease system—animal tuberculosis—thriving both across temperate and semi-arid regions and involving environmental contamination. The biocide activity of a commercial sodium dichloroisocyanurate (NaDCC) disinfectant against M. bovis BCG was evaluated through mock environmental matrix tests. Using the manufacturer-recommended dosage of NaDCC, BCG cells were apparently inactivated after 24 h upon exposure. However, we show via flow cytometry that, upon exposure to optimal growth conditions, mycobacterial cells were able to regain metabolic activity shortly after, highlighting a sublethal effect of NaDCC at the recommended commercial dosage due to reversible BCG cell damage. In contrast, increasing twice the disinfectant dosage completely inactivated BCG cells after 24 h of exposure, with full irreversible loss of metabolic activity. Methodological workflows based on conventional culture or PCR would have missed the detection of these dormant subpopulations that were in fact able to resume growth when following the recommendations of a commercial disinfectant. This study highlights the superior, high-resolution value of single-cell approaches, such as flow cytometry, to accurately assess the activity of biocides against metabolically heterogeneous and dormant pathogenic bacteria with environmental cycles, supporting data-driven prioritization of environmental management and disinfection options in contaminated vulnerable settings. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF