1. Single-dock Robotic Bilateral Transversus Abdominis Release: Technique Description and Preliminary Outcomes.
- Author
-
Estrada A, Rodriguez-Quintero JH, Arias-Espinosa L, Sreeramoju P, Cheema F, Pereira X, and Malcher F
- Abstract
Background: Posterior component separation with transversus abdominis release (TAR) is a valuable adjunct to address incisional hernia defects. Currently, bilateral docking is a standard technique for robotic TAR. The aim of this study is to describe our technique for extended totally extraperitoneal (eTEP) repair with bilateral TAR through a bottom single-dock robotic approach for hernias at the level of the umbilicus or higher., Materials and Methods: We retrospectively reviewed a case series of patients who underwent robotic eTEP repair with bilateral TAR using a single bottom docking between November 2021 and November 2023. A comprehensive description of our patient selection, surgical technique, and short-term clinical outcomes is reported., Results: Ten patients with incisional hernias were included. Their median age was 55 years (IQR: 49.5 to 61.25), 70% were male, the median BMI was 27.25 kg/m (IQR: 22.95 to 33.53), and ASA class was ≥2 in 80%. Median hernia width was 10 cm (IQR: 6.75 to 12.25) and length 11 cm (IQR: 9.25 to 16.25). The median operative time was 178.5 minutes (IQR: 153.75 to 222), and the length of stay was 1 day (IQR: 0.75 to 1.75). At a median follow-up of 5 months (IQR: 2.6 to 9.7), 20% of patients developed a surgical site occurrence requiring procedural intervention., Conclusion: Bilateral TAR using a single bottom dock is a feasible and safe adjunct to robotic eTEP ventral hernia repair in appropriately selected patients., Competing Interests: F.M. discloses consulting fees from BD, Intuitive, Integra, DeepBlue, Allergan, and Medtronic, outside the submitted study. The remaining authors declare no conflicts of interest., (Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF