1. Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement.
- Author
-
Chang S, Jung JI, Beck KS, Chang K, Kim Y, and Han K
- Subjects
- Humans, Male, Female, Aged, 80 and over, Aged, Acute Kidney Injury etiology, Acute Kidney Injury diagnostic imaging, Aortic Valve Stenosis surgery, Aortic Valve Stenosis diagnostic imaging, Radiography, Dual-Energy Scanned Projection methods, Radiation Dosage, Reproducibility of Results, Renal Insufficiency, Retrospective Studies, Signal-To-Noise Ratio, Contrast Media, Transcatheter Aortic Valve Replacement methods, Transcatheter Aortic Valve Replacement adverse effects, Tomography, X-Ray Computed methods
- Abstract
Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function., Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed., Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR ( P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration., Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function., Competing Interests: Kyunghwa Han, who holds the respective position of Statistical Consultant of the Korean Journal of Radiology, was not involved in the editorial evaluation or decision to publish this article. The remaining author has declared no conflicts of interest., (Copyright © 2024 The Korean Society of Radiology.)
- Published
- 2024
- Full Text
- View/download PDF