1. Determination of cortisol cut-off limits and steroid dynamics in the ACTH stimulation test: a comparative analysis using Roche Elecsys Cortisol II immunoassay and LC-MS/MS.
- Author
-
Okutan S, Jørgensen NT, Pedersen LE, Borresen SW, Hilsted L, Hansen LF, Feldt-Rasmussen U, and Klose M
- Subjects
- Humans, Female, Male, Adult, Immunoassay methods, Chromatography, Liquid methods, Middle Aged, Testosterone blood, Young Adult, Cortisone blood, Reference Values, Dehydroepiandrosterone Sulfate blood, Liquid Chromatography-Mass Spectrometry, Hydrocortisone blood, Adrenocorticotropic Hormone blood, Tandem Mass Spectrometry methods
- Abstract
Purpose: Measurement of cortisol concentrations is method dependent. The study aimed to establish assay-specific cut-off limits for cortisol after adrenocorticotropic hormone (ACTH) stimulation, comparing Roche Elecsys Cortisol II immunoassay to liquid chromatography-mass spectrometry (LC-MS/MS), and to assess the impact of patient characteristics, estrogen containing oral contraceptives as well as relation to other adrenocortical steroid hormone dynamics., Methods: One hundred healthy participants underwent a 250 μg ACTH-test, with plasma samples analyzed using ElecsysCortI, ElecsysCortII, and LC-MS/MS. Cortisone, corticosterone, 17-OH-progesterone, dehydroepiandrosterone sulfate (DHEAS), androstenedione, and testosterone were additionally analyzed with LC-MS/MS. Cut-off limit for a normal cortisol response to the ACTH-test was defined as: 2.5th percentile-1.96 × SE., Results: ElecsysCort II measured cortisol concentrations 21% (95% CI: 19-22%) lower than ElecsysCort I. Cut-off limits for cortisol 30 and 60 min after ACTH were 426 and 485 nmol/L (ElecsysCort II) and 411 and 470 nmol/L (LC-MS/MS). Cut-offs were unaffected by gender, or body-composition. The ACTH-test resulted in significantly increased adrenocortical steroid hormones, except for decreased cortisone concentrations (both sexes), and decreased testosterone in men (1.9 nmol/L, 95% CI: 1.3-2.5). Testosterone was increased in women (0.07 nmol/L, 95% CI: 0.02-0.13)., Conclusion: ElecsysCort II has high analytical performance and yields significantly lower cortisol concentrations than prior polyclonal immunoassays. This clinically relevant difference underscores the necessity for revised cut-off limits for improved diagnostic precision. Suggested 30-minute cortisol cutoff limits are 411 nmol/L (LC-MS/MS) and 426 nmol/L (ElecsysCort II). Adrenocortical steroids increased upon ACTH stimulation, except for cortisone in both sexes and testosterone in men, both of which decreased., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF