1. Simultaneous measurement of thrombin generation and fibrin formation in whole blood under flow conditions
- Author
-
Anne Bouwhuis, H. Coenraad Hemker, Adam Miszta, Dana Huskens, Hilde Kelchtermans, Marcus D. Lancé, Evelien Schurgers, Bas de Laat, Leonie Pelkmans, Theo Lindhout, RS: FHML non-thematic output, RS: CARIM - R1.01 - Blood proteins & engineering, Biochemie, Promovendi CD, Anesthesiology, ACS - Microcirculation, and ACS - Pulmonary hypertension & thrombosis
- Subjects
Adult ,Male ,0301 basic medicine ,Blood viscosity ,Blood Loss, Surgical ,In Vitro Techniques ,030204 cardiovascular system & hematology ,Fibrinogen ,Fibrin ,surgery ,03 medical and health sciences ,0302 clinical medicine ,Thrombin ,Predictive Value of Tests ,medicine ,Humans ,Cardiac Surgical Procedures ,Aged ,Whole blood ,fibrinogen/fibrin ,Dose-Response Relationship, Drug ,biology ,Chemistry ,Equipment Design ,Hematology ,Middle Aged ,Thoracic Surgical Procedures ,Blood Viscosity ,bleeding ,Healthy Volunteers ,Thrombelastography ,Thromboelastometry ,030104 developmental biology ,Tissue Plasminogen Activator ,Anesthesia ,flow ,Hemorheology ,biology.protein ,Female ,Protein Multimerization ,Oligopeptides ,medicine.drug ,Biomedical engineering - Abstract
SummaryAssays based on the formation of thrombin and fibrin are frequently used, and results are considered exchangeable in research/clinical settings. However, thrombin generation and fibrin formation do not always go hand in hand and flow profoundly influences thrombus formation. We describe the technical/clinical evaluation of an assay to simultaneously measure thrombin generation and fibrin formation under conditions of flow. Introduction of a fluorometer into a ‘cone and base principle’-based rheometer allowed the measurement of thrombin generation (using a thrombin-sensitive substrate) and fibrin formation (changes in viscosity), while applying a linear shear flow. Increasing shear rates inversely related with thrombin generation and fibrin formation. Increasing fibrinogen concentrations in defibrinated plasma resulted in increased thrombin generation and fibrin formation. In pre-operative samples of 70 patients undergoing cardiothoracic surgery, fibrin formation and thrombin generation parameters correlated with fibrinogen content, rotational thromboelastometry (ROTEM) and whole blood Calibrated Automated Thrombinography (CAT) parameters, respectively. Upon dividing patients into two groups based on the median clot strength, a significant difference in perioperative/total blood loss was established. In conclusion, we clinically evaluated a method capable of simultaneously measuring thrombin generation and fibrin formation in plasma/whole blood under continuous flow, rendering our method one step closer to physiology. Importantly, our test proved to be indicative for the amount of blood loss during/after cardiothoracic surgery.
- Published
- 2016