1. Performance characteristics of INDICAID antigen rapid diagnostic test on SARS-CoV-2 samples during the omicron wave in Cameroon.
- Author
-
Fokam J, Takou D, Semengue ENJ, Molimbou E, Chenwi Ambe C, Durand Nka A, Ndjeyep SD, Beloumou GA, Ka'e CA, Gouissi Anguechia DH, Mundo Nayang AR, Moko Fotso LG, Kengni Ngueko AM, Etame NK, Tueguem PP, Tommo Tchouaket CM, Fainguem N, Abega Abega C, Abba A, Tambe Ayuk Ngwese D, Djubgang Djoukwe R, Akenji B, Okomo Assoumou MC, Mandeng N, Esso L, Cappelli G, Shang J, Ndongmo C, Etoundi Mballa GA, Ndembi N, Colizzi V, Perno CF, and Ndjolo A
- Abstract
Background: WHO recommends the use of COVID-19 antigen rapid diagnostic tests (Ag-RDT) with at least 80 % sensitivity and 97 % specificity. In the era of Omicron variants, we sought to ascertain the performance of the INDICAID™ Ag-RDT compared to real-time PCR (RT-PCR) as the gold standard., Methods: A laboratory-based study was conducted among consenting individuals tested for COVID-19 at the virology laboratory of the Chantal BIYA International Reference Centre, Yaoundé-Cameron. The samples were processed by INDICAID™ Ag-RDT and DaAn Gene real-time PCR according to the manufacturer's instructions, and PCR-results were interpreted as per cycle thresholds (CT). The sensitivity, specificity, positive and negative predictive values (PPV and NVP) of INDICAID™ Ag-RDT were evaluated according to PCR CT-values., Results: A total of 565 nasopharyngeal swabs were collected from participants (median age [IQR]: 40 [31-75]; M/F sex-ratio was 1.2 and 380 were vaccinated). Following PCR, overall COVID-19 positivity was 5.66 %. For CT < 37, INDICAID™ Ag-RDT sensitivity was 21.9 % (95%CI: [8.3-39.9]), specificity 100 % (95%CI: [99.3-100]); PPV 100 % (95%CI: [59.0-100]), NPV 95.5 % (95%CI: [93.4-97.1]) and kappa = 0.34 (95%CI: [0.19-0.35]). For CT < 25, sensitivity was 100 % (95%CI: [47.8-100.0]), specificity 99.6 % (95%CI: [98.7-99.9]); PPV 94.4 % (95%CI: [51.7-100]), NPV 100 % (95%CI: [99.3-100]) and kappa = 0.83 (95%CI: [0.6-1.0]). COVID-19 sequences generated were all Omicron BA.1 subvariants., Conclusion: For patients infected with high viral loads (CT < 25), INDICAID™ Ag-RDT has high intrinsic (sensitivity and specificity) and extrinsic (predictive values) performances for COVID-19 diagnosis. Due to its simplicity and short turnaround time, INDICAID™ Ag-RDT is, therefore a reliable tool to prevent the spread of COVID-19 at community level in the current era of Omicron subvariants., Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (© 2024 The Authors. Published by Elsevier Ltd.)
- Published
- 2024
- Full Text
- View/download PDF