In this study, we describe an optimised procedure for fabricating carbon fiber electrodes using Taguchi quality engineering method (TQEM). The preliminary results show a S/N ratio improvement from 22 to 30 db (decibel). The optimised parameter was tested by using a glass micropipette (0.3 mm outer/2.5 mm inner length of carbon fiber) dipped into PBS solution under 2.9 V triangle-wave electrochemical processing for 15 s, followed by coating treatment of micropipette on 2.6 V DC for 45 s in 5% Nafion solution. It is thus shown that Taguchi process optimisation can improve cost, manufacture time and quality of carbon fiber electrodes.