28 results on '"Marta Arias"'
Search Results
2. Comparison of efficacy and safety of the new generation helixone dialyzers
- Author
-
Francisco Maduell, José Jesús Broseta, Diana Rodríguez-Espinosa, Lida María Rodas, Miquel Gómez, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Maria del Carmen Salgado, Nayra Rico, and Rosa Ramos
- Subjects
Eficacia ,Helixona ,Hemodiafiltración ,Reacciones adversas ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. Material and methods: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. Results: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34 L. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of β2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5 g lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. Conclusion: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation. Resumen: Introducción: Recientemente se han desarrollado dializadores de helixona de nueva generación como parte del esfuerzo continuo para mejorar la biocompatibilidad del dializador y evitar reacciones adversas a los dializadores sintéticos. Este estudio tuvo como objetivo evaluar el rendimiento y la pérdida de albúmina de esta nueva serie de dializadores en hemodiafiltración y compararla con dializadores de helixona de la generación anterior. Material y métodos: Se realizó un estudio prospectivo en 19 pacientes. Cada paciente recibió ocho sesiones de diálisis con los mismos parámetros de diálisis de rutina; sólo varió el dializador: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax y FX CorAL 800. Los índices de reducción (RR) de urea, creatinina, ß2-microglobulina, mioglobina, cadenas ligeras kappa (κFLC), prolactina, α1-microglobulina, α1-glicoproteína ácida, cadenas ligeras lambda (λFLC) y albúmina se compararon intraindividualmente. También se midió la pérdida de albúmina del dializado. Resultados: Todos los tratamientos fueron bien tolerados. La media de líquido de reposición osciló entre 31 y 34 litros. La comparación de los tratamientos de diálisis no mostró diferencias entre moléculas pequeñas e incluso del tamaño de las β2-microglobulinas. Se encontraron pocas diferencias entre los RR de mioglobina, κFLC, prolactina, α1-microglobulina y λFLC. Las pérdidas de albúmina en el dializado fueron similares, con menos de 2,5 gramos por sesión. El dializador FX80 CorDiax mostró puntuaciones de eliminación global ligeramente más altas que el resto de los evaluados, a excepción del FX CorAL 800. Conclusión: La nueva generación de dializadores de helixona, actualizado para minimizar el riesgo de reacciones adversas, ha mantenido la eficacia y la pérdida de albúmina conseguidas por la generación de helixona previa.
- Published
- 2024
- Full Text
- View/download PDF
3. Correlation of plasmatic sodium determined by the laboratory and that determined by the dialysis machine
- Author
-
Joaquim Casals, José Jesús Broseta, Rosa María Fernández, Diana Rodriguez-Espinosa, Jimena del Risco, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Naira Rico, and Francisco Maduell
- Subjects
Dialisancia iónica ,Hemodiálisis ,individualización ,Sodio plasmático ,Módulo de sodio ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Changes in plasma sodium concentration (pNa, expressed in mEq/L) are common in hemodialysis (HD) patients. Hemodialysis monitors can estimate pNa by using an internal algorithm based on ion dialysance measurements. The present study studies the accuracy of the correlation between the pNa estimated by the dialysis monitor and that measured by the biochemistry laboratory at our center. Material and methods: A single-centre prospective observational study in patients on a chronic HD program with the 6008 CAREsystem monitor and standard sodium (138 mmol/L) and bicarbonate (32 mmol/L) prescriptions. Venous blood samples were drawn from each patient before and after each HD session to ensure inter- and intra-individual validity. The pNa was measured in the biochemistry laboratory using indirect potentiometry and simultaneously the estimated pNa by the HD monitor was recorded at the beginning and at the end of the HD session. For statistical analysis, a scatterplot was made, and Spearman’s correlation quotient was calculated. In addition, the differences between both methods were represented as Bland-Altman diagrams. Results: The pre-dialysis pNa measured in the laboratory was 137.49 ± 3.3, and that of the monitor, 137.96 ± 2.91, with a correlation with R2 value of 0.683 (p
- Published
- 2024
- Full Text
- View/download PDF
4. Correlación entre el sodio plasmático determinado por el laboratorio y el determinado por el monitor de hemodiálisis
- Author
-
Joaquim Casals, José Jesús Broseta, Rosa María Fernández, Diana Rodriguez-Espinosa, Jimena del Risco, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Naira Rico, and Francisco Maduell
- Subjects
Ionic dialysance ,Hemodialysis ,Individualization ,Plasmatic sodium ,Sodium module ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Las alteraciones de la concentración plasmática de sodio (Nap, expresado en mEq/l) son frecuentes en los pacientes en hemodiálisis (HD). Los monitores de HD tienen la capacidad de estimar la Nap mediante un algoritmo interno a partir de las medidas de la dialisancia iónica. En el presente trabajo se estudia la correlación entre la Nap estimada por el monitor de diálisis y la medida en el laboratorio de bioquímica de nuestro centro. Material y métodos: Estudio observacional prospectivo y unicéntrico en los pacientes en programa crónico de HD con el monitor 6008 CAREsystem y prescripción estándar de sodio (138 mEq/l) y bicarbonato (32 mmol/l). De cada paciente se extrajeron muestras de sangre venosa antes y después de la sesión para asegurar validez inter e intraindividual. Se analizó la Nap en el laboratorio mediante potenciometría indirecta y simultáneamente se registraba la estimada por el monitor de HD al inicio y al terminar la sesión. Para el análisis estadístico se realizó un diagrama de dispersión y se calculó el cociente de correlación de Spearman. Además, se representaron las diferencias entre métodos mediante diagramas de Bland-Altman. Resultados: La Nap prediálisis medida en el laboratorio fue de 137,49 ± 3,3, y la del monitor 137,96 ± 2,91, con una correlación con valor de R2 de 0,683 (p
- Published
- 2024
- Full Text
- View/download PDF
5. Comparación de la eficacia y seguridad de la nueva generación dializadores de helixona
- Author
-
Francisco Maduell, José Jesús Broseta, Diana Rodríguez-Espinosa, Lida María Rodas, Miquel Gómez, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Maria del Carmen Salgado, Nayra Rico, and Rosa Ramos
- Subjects
Dialyzer performance ,Helixone ,Hemodiafiltration ,Adverse reactions ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Recientemente se han desarrollado dializadores de helixona de nueva generación como parte del esfuerzo continuo para mejorar la biocompatibilidad del dializador y evitar reacciones adversas a los dializadores sintéticos. Este estudio tuvo como objetivo evaluar el rendimiento y la pérdida de albúmina de esta nueva serie de dializadores en hemodiafiltración y compararla con dializadores de helixona de la generación anterior. Material y métodos: Se realizó un estudio prospectivo en 19 pacientes. Cada paciente recibió ocho sesiones de diálisis con los mismos parámetros de diálisis de rutina; solo varió el dializador: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax y FX CorAL 800. Los índices de reducción (RR) de urea, creatinina, β2-microglobulina, mioglobina, cadenas ligeras kappa (κFLC), prolactina, α1-microglobulina, α1-glicoproteína ácida, cadenas ligeras lambda (λFLC) y albúmina se compararon intraindividualmente. También se midió la pérdida de albúmina del dializado. Resultados: Todos los tratamientos fueron bien tolerados. La media de líquido de reposición osciló entre 31 y 34 litros. La comparación de los tratamientos de diálisis no mostró diferencias entre moléculas pequeñas e incluso del tamaño de las β2-microglobulinas. Se encontraron pocas diferencias entre los RR de mioglobina, κFLC, prolactina, α1-microglobulina y λFLC. Las pérdidas de albúmina en el dializado fueron similares, con menos de 2,5 gramos por sesión. El dializador FX80 CorDiax mostró puntuaciones de eliminación global ligeramente más altas que el resto de los evaluados, a excepción del FX CorAL 800. Conclusión: La nueva generación de dializadores de helixona, actualizada para minimizar el riesgo de reacciones adversas, ha mantenido la eficacia y la pérdida de albúmina conseguidas por la generación de helixona previa. Abstract: Introduction: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. Material and methods: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, β2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. Results: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34 litres. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of β2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5 grams lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. Conclusion: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation.
- Published
- 2024
- Full Text
- View/download PDF
6. Conductivity variations and changes in serum sodium concentration during dialysis related to monitor switching
- Author
-
Francisco Maduell, José Jesús Broseta, Joaquim Casals, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, and Néstor Fontseré
- Subjects
Hemodiálisis ,Sodio ,Conductividad ,Biosensores ,Prescripción de diálisis ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusion: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors. Resumen: Introducción: El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos: Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió 2 sesiones de diálisis en la que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados: El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138.14 mmol/L con 5008 vs 138.81 mmol/L con 6008) y final (139.58 mmol/L vs 140.97 mmol/L), así como en la conductividad real obtenida (13,97 vs 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión: El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores.
- Published
- 2023
- Full Text
- View/download PDF
7. Variaciones de la conductividad y cambios en el sodio plasmático durante hemodiálisis relacionado con el cambio de monitor
- Author
-
Francisco Maduell, José Jesús Broseta, Joaquim Casals, Miquel Gómez, Lida M. Rodas, Marta Arias-Guillén, Manel Vera, and Néstor Fontseré
- Subjects
Hemodialysis ,Sodium ,Conductivity ,Biosensors ,Dialysis prescription ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos: Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió dos sesiones de diálisis en las que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados: El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138,14 mmol/L con 5008 vs. 138,81 mmol/L con 6008) y final (139,58 mmol/L vs. 140,97 mmol/L), así como en la conductividad real obtenida (13,97 vs. 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión: El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores. Abstract: Introduction: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusión: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors.
- Published
- 2023
- Full Text
- View/download PDF
8. Efficacy of systematic catheter locks solution of taurolidine/heparin versus taurolidine/urokinase in end-stage renal insufficiency stage 5D
- Author
-
Néstor Fontseré, Alex Soriano, Gaspar Mestres, Patricia Bermudez, Federico Zarco, Valentín Lozano, Lida Rodas, Jose Broseta, Marta Arias, and Francisco Maduell
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Published
- 2022
- Full Text
- View/download PDF
9. Eficacia de los sellados sistemáticos de catéter con taurolidina/heparina versus taurolidina/uroquinasa en pacientes con insuficiencia renal crónica estadio 5D
- Author
-
Néstor Fontseré, Alex Soriano, Gaspar Mestres, Patricia Bermudez, Federico Zarco, Valentín Lozano, Lida Rodas, Jose Broseta, Marta Arias, and Francisco Maduell
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Published
- 2022
- Full Text
- View/download PDF
10. Guía de unidades de hemodiálisis 2020
- Author
-
Guillermo Alcalde-Bezhold, Roberto Alcázar-Arroyo, Manuel Angoso-de-Guzmán, María Dolores Arenas, Marta Arias-Guillén, Patricia Arribas-Cobo, Juan Manuel Díaz-Gómez, Rafael García-Maset, Emilio González-Parra, Domingo Hernández-Marrero, José Antonio Herrero-Calvo, Francisco Maduell, Pablo Molina, Manuel Molina-Núñez, Alfonso Otero-González, Julio Pascual, Mónica Pereira-García, Rafael Pérez-García, María Dolores del Pino y Pino, Mario Prieto-Velasco, Juan Francisco Pulido Pulido, José Emilio Sánchez-Álvarez, Rosa Sánchez-Hernández, Patricia de Sequera-Ortiz, Rafael Pérez García, María Dolores del Pino Pino, Carlos Quereda Rodríguez-Navarro, Guillermo Alcalde Bezhold, Roberto Alcázar Arroyo, Manuel Angoso de Guzmán, Mª Dolores Del Pino y Pino, Domingo Hernández Marrero, Alfonso Otero González, Dolores Arenas Jiménez, Ángel Martín de Francisco Hernández, Alejandro Martín Malo, Rosa Inés Muñoz González, Rafael Díaz-Tejeiro Izquierdo, Milagros Fernández Lucas, Eduardo Gutiérrez Martínez, Raquel Ojeda López, Mario Prieto Velasco, Patrocinio Rodríguez Benítez, Alfredo José Sáenz Santolaya, María Fernanda Slon Roblero, José Luis Teruel Briones, and Fernando Tornero Molina
- Subjects
Clinical guidelines ,S.E.N. ,Hemodialysis ,Hemodialysis centers ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Presentamos una nueva edición de la Guía de Centros de Hemodiálisis. Se enmarca en el programa de actualización de las Guías Clínicas de la Sociedad Española de Nefrología. Es un documento de consenso en el que han colaborado nefrólogos con amplia experiencia en diálisis y expertos de la enfermería nefrológica. La Guía ha sido corregida por un grupo de evaluadores externos. Se ha informado y se ha tomado en consideración la opinión de los pacientes a través de la Asociación de Enfermos Renales (ALCER). Esta Guía incluye en sus diez capítulos aspectos arquitectónicos, logísticos y organizativos. Hace especial énfasis en las necesidades de recursos humanos y su cualificación. Revisa las modalidades actuales de hemodiálisis, su dosificación y adecuación y la monitorización y seguimiento intra e interdiálisis. La hemodiálisis es una de las formas de tratamiento renal sustitutivo, por lo que menciona la necesidad de la inclusión en lista de espera para trasplante y la relación con las unidades de diálisis peritoneal. La calidad de vida del paciente en hemodiálisis comprende la necesidad de relacionarse y viajar por lo que se revisa y estandariza la atención de los pacientes transeúntes. La gestión de calidad es una herramienta necesaria actualmente para lograr la mejora continua de cualquier procedimiento como la hemodiálisis. Esta Guía pretende ser una ayuda para el buen funcionamiento de las Unidades de Diálisis, para los responsables de las mismas, así como para los gestores sanitarios. Abstract: We present a new edition of the Hemodialysis Center Guide. It is part of the program of updating the Clinical Guides of the Spanish Society of Nephrology. It is a consensus document in which nephrologists with extensive experience in dialysis and experts in nephrological nursing have collaborated. The Guide has been corrected by a group of external evaluators. The opinion of the patients through the kidney diseases patient association (ALCER) has been reported and taken into consideration. This Guide includes in its ten chapters architectural, logistical and organizational aspects. It places special emphasis on human resources needs and their qualification. Review current hemodialysis modalities, dosage and adequacy, and intra and interdialysis monitoring. Hemodialysis is one of the forms of renal replacement therapy, so it mentions the need for transplant waiting list inclusion and the relationship with peritoneal dialysis units. The patient's quality of life on hemodialysis understands the need to relate and travel so care of transitory patients is reviewed and standardized. Quality management is a tool currently needed to achieve continuous improvement of any procedure such as hemodialysis. This Guide is intended to be an aid for the proper functioning of the Dialysis Units, for those responsible for them, as well as for health managers.
- Published
- 2021
- Full Text
- View/download PDF
11. Eficacia y seguridad de un programa de ejercicio físico intradiálisis
- Author
-
Anna Yuguero-Ortiz, Miquel Gomez, Marta Arias-Guillén, Raquel Ojeda, Néstor Fontseré, Lida Rodas, José Jesús Broseta, Manel Vera, Sonsoles Hernandez-Sanchez, and Francisco Maduell
- Subjects
Intradialytic physical exercise program ,Cardiopulmonary capacity ,Muscular strength ,Vascular refilling profile ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Los pacientes en hemodiálisis (HD) suelen tener una condición física mermada y elevado sedentarismo. La consolidación de programas de ejercicio físico en las unidades de diálisis está limitada por barreras como la seguridad inherente a estos programas y la falta de recursos. Objetivos: Evaluar la eficacia y seguridad en la implantación de un programa de ejercicio físico intradiálisis (EFI) sobre la condición física de los pacientes con un equipo multidisciplinar (fisioterapeuta y auxiliares de enfermería). Material y métodos: Estudio cuasiexperimental pre-post unicéntrico prospectivo de 6 meses en 34 pacientes. Intervención con EFI combinado 2 días a la semana, evaluándose de forma basal y final la capacidad cardiorrespiratoria (6MWT), fuerza muscular (HG, dinamometría de cuádriceps y 10STS), la composición corporal (bioimpedanciometría) y la capacidad coordinativa (Timed Up and Go test). La seguridad se valoró registrando las incidencias relacionadas con el acceso vascular, la estabilidad hemodinámica y el perfil de rellenado vascular (RBV) durante las sesiones. También se registró la adherencia al programa así como parámetros analíticos habituales. Resultados: La adherencia al programa de EFI fue elevada (70,8%). Se constató una mejora significativa de 47 m (p
- Published
- 2021
- Full Text
- View/download PDF
12. Impact and safety outcomes of an intradialytic physical exercise program
- Author
-
Anna Yuguero-Ortiz, Miquel Gomez, Marta Arias-Guillén, Raquel Ojeda, Néstor Fontseré, Lida Rodas, José Jesús Broseta, Manel Vera, Sonsoles Hernandez-Sanchez, and Francisco Maduell
- Subjects
Ejercicio físico intradiálisis ,Capacidad cardiorrespiratoria ,Fuerza muscular ,Rellenado vascular ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Patients undergoing hemodialysis (HD) are characterized by a poor physical condition and a substantial sedentary profile. The implementation of physical exercise programs in the hemodialysis units is usually limited by the inherent safeness and the lack of appropriate resources. Objectives: We aimed to evaluate the impact and safety outcomes of the implementation of an intradialytic physical exercise program (IPE) by a multidisciplinary team (physiotherapist and nursing assistant) in the physical condition of the patients. Material and methods: This six months single-centre and experimental pre-post prospective study was carried out in 34 patients. A two day-week combined IPE intervention was implemented. The cardiopulmonary capacity (6MWT), muscular strength (HG, leg dynamometry and 10STS), body composition (bioimpedance) and coordination capacity (Timed Up and Go test) was assessed at the beginning and at the end of the study. Safety was evaluated by means of the number of issues regarding the vascular access, the hemodynamic stability as well as the vascular refilling profile (RBV) in each session. The adhesion to the program was also registered. Additionally, analytical parameters were recorded. Results: The adhesion to an IPE program was high (70.8%). A significant improvement of the cardiopulmonary capacity (6MWT average increase 47 m; p
- Published
- 2021
- Full Text
- View/download PDF
13. Evaluation of the influence of the surface membrane and blood flow in medium «cut-off» (MCO) dialyzers
- Author
-
Francisco Maduell, Lida Rodas, José Jesús Broseta, Miquel Gómez, Enrique Montagud-Marrahi, Elena Guillén, Evelyn Hermida, Marc Xipell, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, and Nayra Rico
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Recently, a new class of dialyzers, medium cut-off membranes (MCO), designed to improve the permeability, which could provide an efficacy similar to hemodiafiltration, have been incorporated into our therapeutic possibilities. To increase the knowledge about its use, the objective of the study was to evaluate the effect of the surface and blood flow (Qb) on the depurative efficacy in the MCO membranes. Material and methods: We included 19 patients in the hemodialysis. Each patient received 6 sessions, in which the membrane surface was varied, 1.7 or 2.0 m2, and/or the Qb (300, 350, 400 or 450 mL/min). In each session, different solutes were determined at the beginning and end of dialysis. Results: The surface change of the dialyzer did not show significant differences in the removal of small or large molecules, without changes in albumin loss. The increase in Qb was accompanied by an increase in clearance of small molecules, without showing differences in the percentage reduction of β2-microglobulin, myoglobin, prolactin, α1-microglobulin and α1-acid glycoprotein, except for some comparison with Qb 450 mL/min. There were also no differences in the loss of albumin in the dialysis fluid, less than 2.5 grams in all situations. Conclusion: The increase of the surface area of 1.7–2.0 m2 in the MCO dialyzer has not meant a greater depurative effectiveness. In these dialyzers the increase of Qb does not seem to be as determinant as in hemodiafiltration except for the clearance of small molecules. Resumen: Introducción: Recientemente, se han incorporado en nuestras posibilidades terapéuticas, una nueva clase de dializadores, membranas de medio cut-off (MCO), diseñados para mejorar la permeabilidad y podrían alcanzar una eficacia similar a la hemodiafiltración. Para aumentar el conocimiento sobre su utilización, el objetivo del estudio fue valorar en las membranas de MCO el efecto de la superficie y del flujo sanguíneo (Qb) sobre la eficacia depurativa. Material y métodos: Se incluyeron 19 pacientes en programa de hemodiálisis. Cada paciente recibió 6 sesiones, en las que se varió la superficie de membrana, 1.7 o 2.0 m2, y el Qb (300, 350, 400 o 450 mL/min). En cada sesión se determinaron diferentes solutos al inicio y al final de diálisis. Resultados: El cambio de superficie del dializador no mostró diferencias significativas en la depuración de pequeñas o grandes moléculas, sin cambios en la pérdida de albúmina. El aumento del Qb se acompaño de un aumento de depuración de pequeñas moléculas, sin mostrar diferencias en el porcentaje de reducción de β2-microglobulina, mioglobina, prolactina, α1-microglobulina y α1-glicoproteína ácida, a excepción de alguna comparación con Qb 450 mL/min. Tampoco se observaron diferencias en la pérdida de albúmina en el líquido de diálisis, inferior a 2.5 gramos en todas las situaciones. Conclusión: El incremento de la superficie de 1.7 a 2.0 m2 en el dializador de MCO no ha significado una mayor eficacia depurativa. En estos dializadores el aumento del Qb no parece ser tan determinante como en la hemodiafiltración a excepción de la depuración de pequeñas moléculas. Keywords: Dialyzer, Efficacy, Hemodiafiltration, Medium cut-off, Palabras clave: Dializador, Eficacia, Hemodiafiltración, Medio cut-off
- Published
- 2019
- Full Text
- View/download PDF
14. Valoración de la influencia de la superficie de la membrana y el flujo sanguíneo en dializadores de medio cut-off
- Author
-
Francisco Maduell, Lida Rodas, José Jesús Broseta, Miquel Gómez, Enrique Montagud-Marrahi, Elena Guillén, Evelyn Hermida, Marc Xipell, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, and Nayra Rico
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Resumen: Introducción: Recientemente, se ha incorporado a nuestras posibilidades terapéuticas una nueva clase de dializadores, las membranas de medio cut-off (MCO), diseñadas para mejorar la permeabilidad y que podrían alcanzar una eficacia similar a la hemodiafiltración. Para aumentar el conocimiento sobre su uso, el objetivo del estudio fue valorar en las membranas de MCO el efecto de la superficie y del flujo sanguíneo (Qb) sobre la eficacia depurativa. Material y métodos: Se incluyó a 19 pacientes en programa de hemodiálisis. Cada paciente recibió 6 sesiones, en las que se varió la superficie de membrana, de 1,7 o 2,0 m2, y el Qb (300, 350, 400 o 450 mL/min). En cada sesión se determinaron diferentes solutos al inicio y al final de la diálisis. Resultados: El cambio de superficie del dializador no mostró diferencias significativas en la depuración de pequeñas o grandes moléculas, sin cambios en la pérdida de albúmina. El aumento del Qb se acompañó de un aumento de depuración de pequeñas moléculas, sin mostrar diferencias en el porcentaje de reducción de β2-microglobulina, mioglobina, prolactina, α1-microglobulina y α1-glicoproteína ácida, a excepción de alguna comparación con Qb 450 mL/min. Tampoco se observaron diferencias en la pérdida de albúmina en el líquido de diálisis, inferior a 2,5 g en todas las situaciones. Conclusión: El incremento de la superficie de 1,7 a 2,0 m2 en el dializador de MCO no ha significado una mayor eficacia depurativa. En estos dializadores el aumento del Qb no parece ser tan determinante como en la hemodiafiltración, a excepción de la depuración de pequeñas moléculas. Abstract: Introduction: Recently, a new class of dialyzers, medium cut-off membranes (MCO), designed to improve the permeability, which could provide an efficacy similar to hemodiafiltration, have been incorporated into our therapeutic possibilities. To increase the knowledge about its use, the objective of the study was to evaluate the effect of the surface and blood flow (Qb) on the depurative efficacy in the MCO membranes. Material and methods: We included 19 patients in the hemodialysis. Each patient received 6 sessions, in which the membrane surface was varied, from 1.7 to 2.0 m2, and/or the Qb (300, 350, 400 or 450 mL/min). In each session, different solutes were determined at the beginning and end of dialysis. Results: The surface change of the dialyzer did not show significant differences in the removal of small or large molecules, without changes in albumin loss. The increase in Qb was accompanied by an increase in clearance of small molecules, without showing differences in the percentage reduction of β2-microglobulin, myoglobin, prolactin, α1-microglobulin and α1-acid glycoprotein, except for some comparison with Qb 450 mL/min. There were also no differences in the loss of albumin in the dialysis fluid, less than 2.5 g in all situations. Conclusion: The increase of the surface area from 1.7 to 2.0 m2 in the MCO dialyzer has not meant a greater depurative effectiveness. In these dialyzers the increase of Qb does not seem to be as determinant as in hemodiafiltration except for the clearance of small molecules. Palabras clave: Dializador, Eficacia, Hemodiafiltración, Medio cut-off, Keywords: Dialyzer, Efficacy, Hemodiafiltration, Medium cut-off
- Published
- 2019
- Full Text
- View/download PDF
15. A new generation of cellulose triacetate suitable for online haemodiafiltration
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Lida Rodas, Miquel Gómez, Karen P. Huablocho, Fanny Esquivel, Paola D. Mori, Valentina Hoffmann, Jessica Ugalde, and Nayra Rico
- Subjects
Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Background: Online haemodiafiltration (OL-HDF) is currently the most effective dialysis technique that also improves survival. To date, high permeability membranes with low albumin loss, such as polysulfone, polyamide and polyacrylonitrile membranes have been the most widely used. However, the initially restricted use of cellulose triacetate (CTA) membranes in OL-HDF has expanded. The aim of the study was to ascertain whether the latest generation asymmetric CTA membranes are more effective in obtaining high convective transport. Patients and methods: A total of 16 patients (10 males and 6 females) undergoing OL-HDF were studied. Each patient underwent 4 different sessions, with haemodialysis or OL-HDF, and/or with CTA or asymmetric CTA 1.9 m2 membranes. Each session was assigned in a randomised order. Serum levels of urea, creatinine, β2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein and albumin where measured at the beginning and end of each session to obtain the reduction rate. The loss of solutes and albumin was quantified from the dialysate. Results: A significantly greater replacement volume in OL-HDF (32.1 ± 3.1 vs. 19.7 ± 4.5 l, pÂ
- Published
- 2018
- Full Text
- View/download PDF
16. Una nueva generación de triacetato de celulosa adecuado para hemodiafiltración on-line
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Lida Rodas, Miquel Gómez, Karen P. Huablocho, Fanny Esquivel, Paola D. Mori, Valentina Hoffmann, Jessica Ugalde, and Nayra Rico
- Subjects
Biocompatibilidad ,Hemodiafiltración on-line ,Triacetato de celulosa ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Antecedentes: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica de hemodiálisis (HD) más efectiva y aumenta la supervivencia. Hasta el momento presente las membranas de alta permeabilidad con baja pérdida de albúmina como las de polisulfona, poliamida y poliacrilonitrilo son las más utilizadas. Las membranas de triacetato de celulosa (TAC), limitadas inicialmente para su uso en HDF-OL, han evolucionado. El objetivo del estudio fue determinar si las membranas de nueva generación de TAC asimétrico (TACA) son más adecuadas para realizar alto transporte convectivo. Pacientes y métodos: Se estudiaron 16 pacientes, 10 hombres y 6 mujeres, en programa de HDF-OL. A cada paciente se le realizaron 4 sesiones diferentes, con HD o HDF-OL, o con filtros de TAC o TACA de 1,9 m2, aleatorizando el orden. En cada sesión se determinaron concentración de urea, creatinina, β2-microglobulina, mioglobina, prolactina, α1-microglobulina, α1-glicoproteína ácida y albúmina en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción. Así mismo, se cuantificó la pérdida de solutos y albúmina en el líquido de diálisis. Resultados: Con las membranas de TACA se consiguió un volumen de sustitución en HDF-OL significativamente superior a las membranas de TAC clásicas (32,1 ± 3,1 vs. 19,7 ± 4,5 L; p
- Published
- 2018
- Full Text
- View/download PDF
17. Evaluation of the dialyzer inner diameter in online haemodiafiltration
- Author
-
Francisco Maduell, Raquel Ojeda, Lara Belmar, Paula Munguía, Cristina Sango, Ana Isabel Martinez-Díaz, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Miquel Gómez, Lida Rodas, and Nayra Rico
- Subjects
Dialyzer ,Inner diameter ,Online haemodiafiltration ,Convective volume ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Online haemodiafiltration (OL-HDF) has been associated with increased survival. To date, the influence of the inner diameter of the hollow fibers of the dialyzer on convective volume has not been well established. The objective of the study was to evaluate the effect of increasing the inner diameter of the dialyzer on the convective volume and removal capacity. Material and methods: We included 16 patients in postdilutional OL-HDF. Each patient was analyzed in 4 sessions in which the inner diameter varied; 185 μm (FX60 Cordiax and FX80 Cordiax) vs. 210 μm (FX600 Cordiax and FX800 Cordiax). Different solutes were measured at the beginning and end of each dialysis session. Results: No differences in the convective volume were found with an increased inner diameter: 32.3 ± 3.1 vs. 31.8 ± 3.6 L/session (FX60 vs. FX600) and 33.7 ± 4.3 vs. 33.5 ± 3.8 L/session (FX80 vs. FX800). The reduction ratios also did not differ: urea 83.7 ± 4.5 vs. 84.1 ± 3.4 for FX60 and FX600, and 82.7 ± 4.1 vs. 83.6 ± 3.8 for FX80 vs. FX800; creatinine similar 78.2 ± 5.6 vs. 77.8 ± 4.6 and 77.1 ± 5.4 vs. 78.1 ± 4.9; β2-microglobulin 82.2 ± 4.3 vs. 82.9 ± 4.2, and 82.9 ± 4.7 vs. 84.0 ± 3.8; myoglobin 71.0 ± 10 vs. 70.2 ± 9 and 72.8 ± 11 vs. 75.0 ± 10; prolactin 70.4 ± 9 vs. 68.1 ± 9, and 72.2 ± 10 vs. 73.4 ± 8.2; and α1-microglobulin 22.9 ± 10 vs. 21.6 ± 10, and 26.5 ± 12 vs. 28.8 ± 11, respectively. Conclusion: The increase in the inner diameter of the hollow fibers did not result in improved convective volume and removal capacity.
- Published
- 2018
- Full Text
- View/download PDF
18. Valoración del diámetro interno del dializador en hemodiafiltración on-line
- Author
-
Francisco Maduell, Raquel Ojeda, Lara Belmar, Paula Munguía, Cristina Sango, Ana Isabel Martinez-Díaz, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Miquel Gómez, Lida Rodas, and Nayra Rico
- Subjects
Dializador ,Diámetro interno ,Hemodiafiltración on-line ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: Se ha asociado la hemodiafiltración on-line (HDF-OL) a un aumento de la supervivencia. Hasta el momento no está bien establecida la influencia del diámetro interno de las fibras capilares del dializador sobre la capacidad convectiva. El objetivo del estudio fue valorar el efecto del aumento del diámetro interno del dializador sobre el volumen convectivo y la capacidad depurativa. Material y métodos: Se incluyeron 16 pacientes en HDF-OL posdilucional con reposición automática. Cada paciente recibió 4 sesiones, en las que se varió el diámetro interno, 185 μm (FX60 Cordiax y FX80 Cordiax) versus 210 μm (FX600 Cordiax y FX800 Cordiax). En cada sesión se determinaron diferentes solutos al inicio y al final de la diálisis. Resultados: El incremento de diámetro interno entre FX60 vs. FX600 y FX80 vs. FX800 no reflejó diferencias en el volumen convectivo: 32,3 ± 3,1 vs. 31,8 ± 3,6 y 33,7 ± 4,3 vs. 33,5 ± 3,8 L/sesión, respectivamente. Los porcentajes de reducción tampoco mostraron diferencias: urea 83,7 ± 4,5 vs. 84,1 ± 3,4 para FX60 y FX600 y 82,7 ± 4,1 vs. 83,6 ± 3,8 para FX80 vs. FX800; creatinina similar 78,2 ± 5,6 vs. 77,8 ± 4,6 y 77,1 ± 5,4 vs. 78,1 ± 4,9; β2-microglobulina 82,2 ± 4,3 vs. 82,9 ± 4,2 y 82,9 ± 4,7 vs. 84,0 ± 3,8; mioglobina 71,0 ± 10, vs. 70,2 ± 9 y 72,8 ± 11 vs. 75,0 ± 10; prolactina 70,4 ± 9 vs. 68,1 ± 9 y 72,2 ± 10 vs. 73,4 ± 8,2; y α1-microglobulina 22,9 ± 10 vs. 21,6 ± 10 y 26,5 ± 12 vs. 28,8 ± 11, respectivamente. Conclusión: El incremento del diámetro interno de las fibras capilares no ha significado una mayor eficacia en el volumen convectivo ni en la capacidad depurativa.
- Published
- 2018
- Full Text
- View/download PDF
19. Optimización del flujo del líquido de diálisis en la hemodiafiltración on-line
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Elisabeth Massó, Miquel Gómez, Lida Rodas, Giannina Bazán, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Flujo líquido diálisis ,Hemodiafiltración on-line ,Eficacia depurativa ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica más efectiva. Varios estudios aleatorizados y metaanálisis han observado una reducción de la mortalidad, con una asociación en relación directa con el volumen convectivo. En el momento presente no está bien establecido si el aumento del flujo del líquido de diálisis (Qd) puede suponer mejores resultados en términos de eficacia convectiva y depurativa. El objetivo del estudio fue valorar, en pacientes en tratamiento con HDF-OL, el efecto de la variación del Qd sobre el volumen convectivo y su capacidad depurativa. Material y métodos: Se incluyeron 59 pacientes, 45 varones y 14 mujeres que se encontraban en programa de HDF-OL con monitor 5008 Cordiax con autosustitución. Cada paciente fue analizado en 5 sesiones con HDF-OL posdilucional, con dializadores de helixona, en las que solo se varió el Qd (300, 400, 500, 600 y 700 ml/min). En cada sesión se determinaron concentración de urea (60 Da), creatinina (113 Da), β2-microglobulina (11.800 Da), mioglobina (17.200 Da) y α1-microglobulina (33.000 Da) en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción de estos solutos. Resultados: Se objetivó un aumento de litros de Qd por sesión, desde 117,9 ± 6,4 L con Qd de 300 ml/min hasta 232,4 ± 12 L con Qd 700 ml/min. No se determinaron cambios en el volumen de sustitución ni en el volumen convectivo. En términos de difusión, el incremento del Qd mostró un aumento significativo de la dosis de diálisis, con un aumento de Kt de 68 ± 6,9 L con Qd 300 ml/min hasta 75,5 ± 7,3 L con Qd 700 ml/min (p
- Published
- 2015
- Full Text
- View/download PDF
20. Optimisation of dialysate flow in on-line hemodiafiltration
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Néstor Fontseré, Manel Vera, Elisabeth Massó, Miquel Gómez, Lida Rodas, Giannina Bazán, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Dialysate flow ,On-line hemodiafiltration ,Efficacy ,Convective volume ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Currently, on-line hemodiafiltration (OL-HDF) is the most effective technique. Several randomised studies and meta-analyses have shown a reduced mortality and a direct association with convective volume has been reported. At present, it has not been established if an increased dialysate flow (Qd) shows in improved results in terms of convective and depurative efficiency. We aim at assessing the effects of Qd variations on convective volume and its depurative capacity in patients on OL-HDF. Material and methods: A total of 59 patients (45 men and 14 women) from a OL-HDF programme in which a monitor 5008 Cordiax with auto-substitution was used, were enrolled. Patients were assessed in 5 sessions with post-dilutional OL-HDF, using helixone-based dialyzers, with only Qd being changed (300, 400, 500, 600 and 700 mL/min). Serum levels of urea (60 Da), creatinine (113 Da), β2-microglobulin (11,800 Da), myoglobin (17,200 Da) and α1-microglobulin (33,000 Da) were measured at the beginning and at the end of each session, in order to estimate the percent reduction of such solutes. Results: An increased dialysate volume per session was observed, from 117.9 ± 6.4 L with Qd 300 mL/min to 232.4 ± 12 L with Qd 700 mL/min. No changes were found in replacement volume or convective volume. Regarding diffusion, Qd increase was associated to a significantly increased dialysis dose, with an increased Kt from 68 ± 6.9 L with Qd 300 mL/min to 75.5 ± 7.3 L with Qd 700 mL/min (P
- Published
- 2015
- Full Text
- View/download PDF
21. Valoración de la superficie del dializador en la hemodiafiltración on-line. Elección objetiva de la superficie del dializador
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Giannina Bazan, Manel Vera, Néstor Fontseré, Elisabeth Massó, Miquel Gómez, Lida Rodas, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Autosustitución ,Hemodiafiltración on-line ,Superficie de membrana ,Volumen convectivo ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introducción: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica más efectiva. Varios estudios aleatorizados y metaanálisis han observado una reducción de la mortalidad, objetivándose una asociación en relación directa con el volumen convectivo. En el momento presente no está bien establecido si el aumento de superficie del dializador puede suponer mejores resultados en términos de eficacia convectiva y depurativa. El objetivo del estudio fue valorar el efecto del aumento de superficie del dializador sobre el volumen convectivo y la capacidad depurativa. Material y métodos: Se incluyeron 37 pacientes (31 varones y 6 mujeres) que se encontraban en programa de HDF-OL con monitor 5008 Cordiax con autosustitución. Cada paciente fue analizado en 3 sesiones en las que solo se varió la superficie del dializador (1,0, 1,4 o 1,8 m2). En cada sesión se determinaron la concentración de urea (60 Da), creatinina (113 Da), β2-microglobulina (11.800 Da), mioglobina (17.200 Da) y α1-microglobulina (33.000 Da) en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción de estos solutos. Resultados: El volumen convectivo alcanzado fue de 29,8 ± 3,0 con 1,0 m2, de 32,7 ± 3,1 (incremento del 6%) con 1,4 m2 y de 34,7 ± 3,3 l (incremento del 16%) con 1,8 m2 (p
- Published
- 2015
- Full Text
- View/download PDF
22. Assessment of dialyzer surface in online hemodiafiltration; objective choice of dialyzer surface area
- Author
-
Francisco Maduell, Raquel Ojeda, Marta Arias-Guillén, Giannina Bazan, Manel Vera, Néstor Fontseré, Elisabeth Massó, Miquel Gómez, Lida Rodas, Mario Jiménez-Hernández, Gastón Piñeiro, and Nayra Rico
- Subjects
Autosubstitution ,Online hemodiafiltration (OL-HDF) ,Membrane surface ,Convective volume ,Diseases of the genitourinary system. Urology ,RC870-923 - Abstract
Introduction: Online haemodiafiltration (OL-HDF) is most effective technique; several randomised studies and meta-analyses have shown a reduction in mortality, with a directly related association with convective volume. At present, it is not properly established whether the increasing in dialyser surface area may suppose better outcomes in terms of convective and clearance efficacy. The purpose of the study was to assess the effect of increase in dialyser surface area on the convective volume and clearance capacity. Materials and methods: A total of 37 patients were included, 31 male and 6 female subjects who were participating in an OL-HDF programme with a 5008 Cordiax monitor with autosubstitution. Each patient was analysed in three sessions, and only the dialyser surface area (1.0, 1.4 or 1.8 m2) varied. In each session, urea (60 Da), creatinine (113 Da), β2-microglobulin (11,800 Da), myoglobin (17,200 Da) and α1-microglobulin (33,000 Da) serum concentration at baseline and at the end of each session were determined, so the reduction of thes solutes could be calculated. Results: Convective volume achieved was 29.8 ± 3.0 with 1.0 m2, 32.7 ± 3.1 (6% increase) with 1.4 m2 and 34.7 ± 3.3 L (16% increase) with 1.8 m2 (p
- Published
- 2015
- Full Text
- View/download PDF
23. Impact and safety outcomes of an intradialytic physical exercise program
- Author
-
Raquel Ojeda, Miquel Gómez, Lida Rodas, Néstor Fontseré, Marta Arias-Guillén, José Jesús Broseta, Anna Yuguero-Ortiz, Manel Vera, Francisco Maduell, and Sonsoles Hernández-Sánchez
- Subjects
030232 urology & nephrology ,Rellenado vascular ,Fuerza muscular ,Diseases of the genitourinary system. Urology ,Vascular refilling profile ,03 medical and health sciences ,0302 clinical medicine ,Muscular strength ,Nephrology ,Ejercicio físico intradiálisis ,030212 general & internal medicine ,RC870-923 ,Capacidad cardiorrespiratoria ,Intradialytic physical exercise program ,Cardiopulmonary capacity - Abstract
Introducción: Los pacientes en hemodiálisis (HD) suelen tener una condición física mermaday elevado sedentarismo. La consolidación de programas de ejercicio físico en las unidadesde diálisis está limitada por barreras como la seguridad inherente a estos programas y lafalta de recursos.Objetivos: Evaluar la eficacia y seguridad en la implantación de un programa de ejerciciofísico intradiálisis (EFI) sobre la condición física de los pacientes con un equipo multidisci-plinar (fisioterapeuta y auxiliares de enfermería).Material y métodos: Estudio cuasiexperimental pre-post unicéntrico prospectivo de 6 mesesen 34 pacientes. Intervención con EFI combinado 2 días a la semana, evaluándose de formabasal y final la capacidad cardiorrespiratoria (6MWT), fuerza muscular (HG, dinamometría decuádriceps y 10STS), la composición corporal (bioimpedanciometría) y la capacidad coordi-nativa (Timed Up and Go test). La seguridad se valoró registrando las incidencias relacionadascon el acceso vascular, la estabilidad hemodinámica y el perfil de rellenado vascular (RBV)durante las sesiones. También se registró la adherencia al programa así como parámetrosanalíticos habituales.Resultados: La adherencia al programa de EFI fue elevada (70,8%). Se constató una mejorasignificativa de 47 m (p < 0,001) en el 6MWT; un incremento medio de 1,6 kg (p = 0,007) enel HG para la fuerza de extremidades superiores y en las extremidades inferiores (10STSp = 0,003; dinamometría p < 0,05). Respecto a la seguridad, no se detectaron incidencias nidiferencias significativas en el RBV.Conclusiones: Un programa de EFI combinado favorece la mejora de la condición física de lospacientes en HD sin comprometer la seguridad del tratamiento. Es aconsejable un equipomultidisciplinar para implantar y dar continuidad eficazmente a un programa de EFI., Introduction: Patients undergoing hemodialysis (HD) are characterized by a poor physical condition and a substantial sedentary profile. The implementation of physical exercise pro- grams in the hemodialysis units is usually limited by the inherent safeness and the lack of appropriate resources. Objectives: We aimed to evaluate the impact and safety outcomes of the implementation of an intradialytic physical exercise program (IPE) by a multidisciplinary team (physiotherapist and nursing assistant) in the physical condition of the patients. Material and methods: This six months single-centre and experimental pre-post prospective study was carried out in 34 patients. A two day-week combined IPE intervention was implemented. The cardiopulmonary capacity (6MWT), muscular strength (HG, leg dynamometry and 10STS), body composition (bioimpedance) and coordination capacity (Timed Up and Go test) was assessed at the beginning and at the end of the study. Safety was evaluated by means of the number of issues regarding the vascular access, the hemodynamic stability as well as the vascular refilling profile (RBV) in each session. The adhesion to the program was also registered. Additionally, analytical parameters were recorded. Results: The adhesion to an IPE program was high (70.8%). A significant improvement of the cardiopulmonary capacity (6MWT average increase 47 m; p < 0.001), superior limbs (HG average increase of 1.6 kg; p = 0.007) as well as the lower extremities (10STS; p = 0.003; dynamometry p < 0.05). Regarding safeness, there were no incidences neither significant difference in the RBV. Conclusions: A combined IPE may contribute to the improvement of the physical condition of the patients as well as ensures a safe development of the HD treatment. We suggest a multidisciplinary team in order to efficiently establish an IPE program.
- Published
- 2021
24. Evaluation of the influence of the surface membrane and blood flow in medium «cut-off» (MCO) dialyzers
- Author
-
Miquel Gómez, Elena Guillen, Marc Xipell, Néstor Fontseré, Manel Vera, Nayra Rico, José Jesús Broseta, Marta Arias-Guillén, Evelyn Hermida, Lida Rodas, Francisco Maduell, and Enrique Montagud-Marrahi
- Subjects
Adult ,Male ,medicine.medical_specialty ,Surface Properties ,medicine.medical_treatment ,030232 urology & nephrology ,Urology ,030204 cardiovascular system & hematology ,lcsh:RC870-923 ,03 medical and health sciences ,chemistry.chemical_compound ,0302 clinical medicine ,Renal Dialysis ,medicine ,Humans ,Prospective Studies ,Membrane surface ,Aged ,Aged, 80 and over ,Dialysis fluid ,Chemistry ,Albumin ,Membranes, Artificial ,Blood flow ,Middle Aged ,lcsh:Diseases of the genitourinary system. Urology ,Surface membrane ,Membrane ,Myoglobin ,Nephrology ,Regional Blood Flow ,Female ,Hemodialysis - Abstract
Introduction: Recently, a new class of dialyzers, medium cut-off membranes (MCO), designed to improve the permeability, which could provide an efficacy similar to hemodiafiltration, have been incorporated into our therapeutic possibilities. To increase the knowledge about its use, the objective of the study was to evaluate the effect of the surface and blood flow (Qb) on the depurative efficacy in the MCO membranes. Material and methods: We included 19 patients in the hemodialysis. Each patient received 6 sessions, in which the membrane surface was varied, 1.7 or 2.0 m2, and/or the Qb (300, 350, 400 or 450 mL/min). In each session, different solutes were determined at the beginning and end of dialysis. Results: The surface change of the dialyzer did not show significant differences in the removal of small or large molecules, without changes in albumin loss. The increase in Qb was accompanied by an increase in clearance of small molecules, without showing differences in the percentage reduction of β2-microglobulin, myoglobin, prolactin, α1-microglobulin and α1-acid glycoprotein, except for some comparison with Qb 450 mL/min. There were also no differences in the loss of albumin in the dialysis fluid, less than 2.5 grams in all situations. Conclusion: The increase of the surface area of 1.7–2.0 m2 in the MCO dialyzer has not meant a greater depurative effectiveness. In these dialyzers the increase of Qb does not seem to be as determinant as in hemodiafiltration except for the clearance of small molecules. Resumen: Introducción: Recientemente, se han incorporado en nuestras posibilidades terapéuticas, una nueva clase de dializadores, membranas de medio cut-off (MCO), diseñados para mejorar la permeabilidad y podrían alcanzar una eficacia similar a la hemodiafiltración. Para aumentar el conocimiento sobre su utilización, el objetivo del estudio fue valorar en las membranas de MCO el efecto de la superficie y del flujo sanguíneo (Qb) sobre la eficacia depurativa. Material y métodos: Se incluyeron 19 pacientes en programa de hemodiálisis. Cada paciente recibió 6 sesiones, en las que se varió la superficie de membrana, 1.7 o 2.0 m2, y el Qb (300, 350, 400 o 450 mL/min). En cada sesión se determinaron diferentes solutos al inicio y al final de diálisis. Resultados: El cambio de superficie del dializador no mostró diferencias significativas en la depuración de pequeñas o grandes moléculas, sin cambios en la pérdida de albúmina. El aumento del Qb se acompaño de un aumento de depuración de pequeñas moléculas, sin mostrar diferencias en el porcentaje de reducción de β2-microglobulina, mioglobina, prolactina, α1-microglobulina y α1-glicoproteína ácida, a excepción de alguna comparación con Qb 450 mL/min. Tampoco se observaron diferencias en la pérdida de albúmina en el líquido de diálisis, inferior a 2.5 gramos en todas las situaciones. Conclusión: El incremento de la superficie de 1.7 a 2.0 m2 en el dializador de MCO no ha significado una mayor eficacia depurativa. En estos dializadores el aumento del Qb no parece ser tan determinante como en la hemodiafiltración a excepción de la depuración de pequeñas moléculas. Keywords: Dialyzer, Efficacy, Hemodiafiltration, Medium cut-off, Palabras clave: Dializador, Eficacia, Hemodiafiltración, Medio cut-off
- Published
- 2019
25. Una nueva generación de triacetato de celulosa adecuado para hemodiafiltración on-line
- Author
-
Manel Vera, Marta Arias-Guillén, Paola D. Mori, Miquel Gómez, Fanny Esquivel, Jessica Ugalde, Néstor Fontseré, Raquel Ojeda, Karen P. Huablocho, Nayra Rico, Valentina Hoffmann, Lida Rodas, and Francisco Maduell
- Subjects
03 medical and health sciences ,0302 clinical medicine ,Hemodiafiltración on-line ,Volumen convectivo ,Nephrology ,030232 urology & nephrology ,Biocompatibilidad ,030204 cardiovascular system & hematology ,lcsh:Diseases of the genitourinary system. Urology ,lcsh:RC870-923 ,Triacetato de celulosa - Abstract
Antecedentes: La hemodiafiltración on-line (HDF-OL) es actualmente la técnica de hemodiálisis (HD) más efectiva y aumenta la supervivencia. Hasta el momento presente las membranas de alta permeabilidad con baja pérdida de albúmina como las de polisulfona, poliamida y poliacrilonitrilo son las más utilizadas. Las membranas de triacetato de celulosa (TAC), limitadas inicialmente para su uso en HDF-OL, han evolucionado. El objetivo del estudio fue determinar si las membranas de nueva generación de TAC asimétrico (TACA) son más adecuadas para realizar alto transporte convectivo. Pacientes y métodos: Se estudiaron 16 pacientes, 10 hombres y 6 mujeres, en programa de HDF-OL. A cada paciente se le realizaron 4 sesiones diferentes, con HD o HDF-OL, o con filtros de TAC o TACA de 1,9 m2, aleatorizando el orden. En cada sesión se determinaron concentración de urea, creatinina, β2-microglobulina, mioglobina, prolactina, α1-microglobulina, α1-glicoproteína ácida y albúmina en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción. Así mismo, se cuantificó la pérdida de solutos y albúmina en el líquido de diálisis. Resultados: Con las membranas de TACA se consiguió un volumen de sustitución en HDF-OL significativamente superior a las membranas de TAC clásicas (32,1 ± 3,1 vs. 19,7 ± 4,5 L; p
- Published
- 2018
26. Valoración del diámetro interno del dializador en hemodiafiltración on-line
- Author
-
Ana Isabel Martinez-Díaz, Paula Munguía, Marta Arias-Guillén, Nayra Rico, Raquel Ojeda, Lara Belmar, Francisco Maduell, Néstor Fontseré, Miquel Gómez, Cristina Sango, Lida Rodas, and Manel Vera
- Subjects
03 medical and health sciences ,0302 clinical medicine ,Hemodiafiltración on-line ,Volumen convectivo ,Dializador ,Nephrology ,030232 urology & nephrology ,030204 cardiovascular system & hematology ,lcsh:Diseases of the genitourinary system. Urology ,lcsh:RC870-923 ,Diámetro interno - Abstract
Resumen Introducción: Se ha asociado la hemodiafiltración on-line (HDF-OL) a un aumento de la supervivencia. Hasta el momento no está bien establecida la influencia del diámetro interno de las fibras capilares del dializador sobre la capacidad convectiva. El objetivo del estudio fue valorar el efecto del aumento del diámetro interno del dializador sobre el volumen convectivo y la capacidad depurativa. Material y métodos: Se incluyeron 16 pacientes en HDF-OL posdilucional con reposición automática. Cada paciente recibió 4 sesiones, en las que se varió el diámetro interno, 185 μm (FX60 Cordiax y FX80 Cordiax) versus 210 μm (FX600 Cordiax y FX800 Cordiax). En cada sesión se determinaron diferentes solutos al inicio y al final de la diálisis. Resultados: El incremento de diámetro interno entre FX60 vs. FX600 y FX80 vs. FX800 no reflejó diferencias en el volumen convectivo: 32,3 ± 3,1 vs. 31,8 ± 3,6 y 33,7 ± 4,3 vs. 33,5 ± 3,8 L/sesión, respectivamente. Los porcentajes de reducción tampoco mostraron diferencias: urea 83,7 ± 4,5 vs. 84,1 ± 3,4 para FX60 y FX600 y 82,7 ± 4,1 vs. 83,6 ± 3,8 para FX80 vs. FX800; creatinina similar 78,2 ± 5,6 vs. 77,8 ± 4,6 y 77,1 ± 5,4 vs. 78,1 ± 4,9; β2-microglobulina 82,2 ± 4,3 vs. 82,9 ± 4,2 y 82,9 ± 4,7 vs. 84,0 ± 3,8; mioglobina 71,0 ± 10, vs. 70,2 ± 9 y 72,8 ± 11 vs. 75,0 ± 10; prolactina 70,4 ± 9 vs. 68,1 ± 9 y 72,2 ± 10 vs. 73,4 ± 8,2; y α1-microglobulina 22,9 ± 10 vs. 21,6 ± 10 y 26,5 ± 12 vs. 28,8 ± 11, respectivamente. Conclusión: El incremento del diámetro interno de las fibras capilares no ha significado una mayor eficacia en el volumen convectivo ni en la capacidad depurativa.
- Published
- 2018
27. Valoración de la superficie del dializador en la hemodiafiltración on-line. Elección objetiva de la superficie del dializador
- Author
-
Néstor Fontseré, Manel Vera, Giannina Bazán, Raquel Ojeda, Lida Rodas, Francisco Maduell, Marta Arias-Guillén, Nayra Rico, Mario Jiménez-Hernández, Elisabeth Massó, Miquel Gómez, and Gastón J Piñeiro
- Subjects
Autosubstitution ,Online hemodiafiltration (OL-HDF) ,Hemodiafiltración on-line ,Volumen convectivo ,Convective volume ,Nephrology ,Membrane surface ,Superficie de membrana ,Autosustitución ,lcsh:Diseases of the genitourinary system. Urology ,lcsh:RC870-923 - Abstract
ResumenIntroducciónLa hemodiafiltración on-line (HDF-OL) es actualmente la técnica más efectiva. Varios estudios aleatorizados y metaanálisis han observado una reducción de la mortalidad, objetivándose una asociación en relación directa con el volumen convectivo. En el momento presente no está bien establecido si el aumento de superficie del dializador puede suponer mejores resultados en términos de eficacia convectiva y depurativa. El objetivo del estudio fue valorar el efecto del aumento de superficie del dializador sobre el volumen convectivo y la capacidad depurativa.Material y métodosSe incluyeron 37 pacientes (31 varones y 6 mujeres) que se encontraban en programa de HDF-OL con monitor 5008Cordiax con autosustitución. Cada paciente fue analizado en 3 sesiones en las que solo se varió la superficie del dializador (1,0, 1,4 o 1,8m2). En cada sesión se determinaron la concentración de urea (60Da), creatinina (113Da), β2-microglobulina (11.800Da), mioglobina (17.200Da) y α1-microglobulina (33.000Da) en suero al inicio y al final de cada sesión, para calcular el porcentaje de reducción de estos solutos.ResultadosEl volumen convectivo alcanzado fue de 29,8±3,0 con 1,0m2, de 32,7±3,1 (incremento del 6%) con 1,4m2 y de 34,7±3,3l (incremento del 16%) con 1,8m2 (p
- Published
- 2015
28. A multi-scale smoothing kernel for measuring time-series similarity
- Author
-
José C. Riquelme, Alicia Troncoso, Marta Arias, Universidad de Sevilla. Departamento de Lenguajes y Sistemas Informáticos, Universitat Politècnica de Catalunya. Departament de Ciències de la Computació, and Universitat Politècnica de Catalunya. LARCA - Laboratori d'Algorísmia Relacional, Complexitat i Aprenentatge
- Subjects
Cognitive Neuroscience ,computer.software_genre ,Kernel principal component analysis ,Similarity ,Artificial Intelligence ,String kernel ,Polynomial kernel ,Machine learning ,Aprenentatge automàtic ,Data mining ,Mathematics ,Support vector machines ,Distance ,Computer Science Applications ,Kernel ,Kernel method ,Kernel embedding of distributions ,Variable kernel density estimation ,Kernel (statistics) ,Radial basis function kernel ,Informàtica::Intel·ligència artificial [Àrees temàtiques de la UPC] ,Mineria de dades ,Algorithm ,computer ,Time-series classification - Abstract
In this paper a kernel for time-series data is introduced so that it can be used for any data mining task that relies on a similarity or distance metric. The main idea of our kernel is that it should recognize as highly similar time-series that are essentially the same but may be slightly perturbed from each other: for example, if one series is shifted with respect to the other or if it slightly misaligned. Namely, our kernel tries to focus on the shape of the time-series and ignores small perturbations such as misalignments or shifts. First, a recursive formulation of the kernel directly based on its definition is proposed. Then it is shown how to efficiently compute the kernel using an equivalent matrix-based formulation. To validate the proposed kernel three experiments have been carried out. As an initial step, several synthetic datasets have been generated from UCR time-series repository and the KDD challenge of 2007 with the purpose of validating the kernel-derived distance over shifted time-series. Also, the kernel has been applied to the original UCR time-series to analyze its potential in time-series classification in conjunction with Support Vector Machines. Finally, two real-world applications related to ozone concentration in atmosphere and electricity demand have been considered. Ministerio de Ciencia y Tecnología TIN2011-27479-C04-03 Ministerio de Ciencia y Tecnología TIN2011-28956-C02 Generalitat de Catalunya 2009-SGR-1428 Junta de Andalucía P12-TIC-1728 Universidad Pablo de Olavide APPB813097 Unión Europea Pascal2 Network of Excellence FP7-ICT-216886 Generalita de Catalunya BE-DGR2011
- Published
- 2015