1. Imaging modality for left ventricular ejection fraction estimation and effect of implantable cardioverter-defibrillator on mortality in patients with heart failure.
- Author
-
Smith A, Kumar S, Moore HJ, Iskandrian AE, Nanda NC, Raman VK, Singh S, Fletcher RD, Deedwania P, Fonarow GC, Greenberg MD, Ahmed A, and Lam PH
- Subjects
- Humans, Ventricular Function, Left, Stroke Volume, Proportional Hazards Models, Death, Sudden, Cardiac epidemiology, Death, Sudden, Cardiac etiology, Death, Sudden, Cardiac prevention & control, Defibrillators, Implantable adverse effects, Heart Failure diagnostic imaging, Heart Failure therapy
- Abstract
Background: Implantable cardioverter-defibrillators (ICDs) improve outcomes in patients with heart failure (HF) with left ventricular ejection fraction (LVEF) ≤35%. Less is known about whether outcomes varied between the 2 noninvasive imaging modalities used to estimate LVEF-2-dimensional echocardiography (2DE) and multigated acquisition radionuclide ventriculography (MUGA)-which use different principles (geometric vs count-based, respectively)., Objective: The purpose of this study was to examine whether the effect of ICD on mortality in patients with HF and LVEF ≤35% varied on the basis of LVEF measured by 2DE or MUGA., Methods: Of the 2521 patients with HF with LVEF ≤35% in the Sudden Cardiac Death in Heart Failure Trial, 1676 (66%) were randomized to either placebo or ICD, of whom 1386 (83%) had LVEF measured by 2DE (n = 971) or MUGA (n = 415). Hazard ratios (HRs) and 97.5% confidence intervals (CIs) for mortality associated with ICD were estimated overall, checking for interaction, and within the 2 imaging subgroups., Results: Of the 1386 patients in the present analysis, all-cause mortality occurred in 23.1% (160 of 692) and 29.7% (206 of 694) of patients randomized to ICD or placebo, respectively (HR 0.77; 97.5% CI 0.61-0.97), which is consistent with that in 1676 patients in the original report. HRs (97.5% CIs) for all-cause mortality in the 2DE and MUGA subgroups were 0.79 (0.60-1.04) and 0.72 (0.46-1.11), respectively (P = .693 for interaction). Similar associations were observed for cardiac and arrhythmic mortalities., Conclusion: We found no evidence that in patients with HF and LVEF ≤35%, the effect of ICD on mortality varied by the noninvasive imaging method used to measure LVEF., (Copyright © 2023 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF