1. Long-term results of revision total knee arthroplasty using a rotating hinge implant.
- Author
-
Wignadasan W, Chang JS, Kayani B, Kontoghiorghe C, and Haddad FS
- Subjects
- Aged, Arthroplasty, Replacement, Knee adverse effects, Female, Follow-Up Studies, Humans, Joint Diseases diagnostic imaging, Knee Joint diagnostic imaging, Knee Joint surgery, Male, Middle Aged, Prosthesis Design, Prosthesis Failure, Range of Motion, Articular, Recovery of Function, Reoperation, Retrospective Studies, Time Factors, Treatment Outcome, Arthroplasty, Replacement, Knee methods, Joint Diseases surgery, Knee Prosthesis
- Abstract
Background: Rotating hinge implants are commonly used in revision total knee arthroplasty (TKA) in the setting of significant ligamentous instability or bone deficiency. These highly constrained implants have been associated with variable clinical outcomes and uncertain long-term survivorship. The aim of this study is to establish long-term functional outcomes, radiographic results, and survivorship after revision TKA with a rotating hinge implant., Method: This is a retrospective study of prospectively collected data of 41 consecutive patients undergoing revision TKA with rotating hinge components and minimum 10-years follow-up. The study included 22 females (53.7%) and 19 males (46.3%) with a mean age of 66.6 ± 8.5 years. Clinical outcomes recorded included the Oxford Knee Score (OKS) preoperatively and at latest follow-up. Range of motion, implant survivorship, and complications were also recorded. Predefined radiological outcomes were obtained using plain radiographs., Results: There was a significant improvement in OKS after revision TKA with a rotating hinge implant compared to preoperative scores (40.7 ± 4.2 vs. 21.4 ± 4.9 respectively, p < 0.001). At latest follow-up, mean range of motion was 111.5° ± 9.3° and mean overall limb alignment was 0.2° ± 2.0° varus. Implant survivorship at minimum 10-year follow-up was 90.2%. Radiographic lucent lines were observed in 14 patients (34.1%)., Conclusion: Revision TKA with a rotating hinge implant leads to satisfactory clinical outcomes and very good implant survivorship at long-term follow-up. Surgeons should have a low threshold to use these versatile implants in complex revision knee arthroplasty., Competing Interests: Declaration of Competing Interest W Wignadasan, JS Chang, B Kayani and C Kontoghiorghe did not receive any financial support and do not have any conflicts of interest. FS Haddad reports board membership of the Bone and Joint Journal and the Annals of the Royal College of Surgeons; consultancy for Smith & Nephew, Corin, MatOrtho and Stryker; payment for lectures including service on speakers’ bureaus for Smith & Nephew and Stryker; royalties paid by Smith & Nephew, MatOrtho, Corin and Stryker, all outside the submitted work., (Copyright © 2020 Elsevier B.V. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF