1. Acute hemodynamic response to biventricular pacing in heart failure patients with narrow, moderately, and severely prolonged QRS duration.
- Author
-
Ploux S, Whinnett Z, Lumens J, Denis A, Zemmoura A, De Guillebon M, Ramoul K, Ritter P, Jaïs P, Clementy J, Haïssaguerre M, and Bordachar P
- Subjects
- Aged, Cardiac Pacing, Artificial, Cardiac Resynchronization Therapy, Female, Hemodynamics, Humans, Male, Middle Aged, Heart Conduction System physiopathology, Heart Failure physiopathology, Heart Failure therapy
- Abstract
Background: The efficacy of biventricular (BiV) pacing in patients with a narrow or moderately prolonged QRS duration remains questionable., Objective: To assess the hypothesis that electrical dyssynchrony is required to obtain hemodynamic benefit from BiV pacing by investigating the relationship between intrinsic QRS duration and hemodynamic response to BiV pacing in a patient population covering a broad spectrum of QRS duration., Methods: Eighty-two consecutive heart failure patients underwent cardiac resynchronization therapy implantation irrespective of their QRS duration. Thirty-four patients had a narrow QRS duration (<120 ms), whereas 11 patients had a moderately prolonged QRS duration (≥120 to <150 ms) and 37 patients had a severely prolonged QRS duration (≥150 ms). After implantation, invasive left ventricular (LV) dP/dt measurements were compared between intrinsic rhythm and simultaneous BiV pacing with an optimized atrioventricular delay., Results: A high correlation (r = .65; P < .001) was observed between baseline QRS duration and changes in LV dP/dt(max) induced by BiV pacing. BiV pacing was ineffective in patients with a narrow QRS duration (+0.4% ± 6.1%; P = ns). No significant increase in LV dP/dt(max) was observed in patients with a QRS duration of ≥120 to <150 ms (+4.4% ± 6.9%; P = .06), whereas patients with a QRS duration of ≥150 ms exhibited a significant increase in LV dP/dt(max) (+17.1% ± 13.4%; P <.001). Only 9% of the patients with a narrow QRS duration exhibited a ≥10% increase in LV dP/dt(max)., Conclusions: Baseline QRS duration is linearly related to acute hemodynamic response to BiV pacing. Patients with a narrow QRS duration do not derive hemodynamic improvement. This improvement is also limited in patients with a moderately prolonged QRS duration, raising questions about the potential clinical benefit of this therapy in these patients., (Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2012
- Full Text
- View/download PDF