1. COMPARISON OF HEMOGRAM PARAMETERS OF SYSMEX XN9000 AND MINDRAY BC-6800 PLUS.
- Author
-
Uresin, Busra, Deniz, Levent, Arslan, Hilmi Furkan, and Isik, Reyhan
- Subjects
- *
REGRESSION analysis , *STATISTICAL correlation , *RANK correlation (Statistics) , *CONFIDENCE intervals , *BLOOD cell count - Abstract
OBJECTIVES: We aimed to compare some hemogram parameters with the Sysmex XN 9000 device that we routinely use to see the performance of the Mindray BC-6800 Plus device, which was newly installed in our laboratory. MATERIALS and METHODS: 80 patient samples were studied simultaneously on Mindray BC-6800 Plus(Shenzhen Mindray Bio-Medical Electronics Co.,Ltd.) and Sysmex XN 9000(Sysmex Corp.) devices, including data below and above the lower and upper reference values. The Kolmogorov Smirnov test was used to evaluate whether the data were compatible with the normal distribution. Spearman correlation analysis and Passing-Bablok regression analysis, Bland-Altman analysis were performed with MedCalc program. RESULTS: For erythrocyte; r = 0.995 (p <0.0001) in correlation analysis, y = 0.01346 + 0.9877x in Passing Bablok regression analysis (95% confidence intervals between slope 0.9759-1.0000, intercept -0.03000 – 0.06060 found.); For leukocyte; r = 0.997 (p <0.0001) in correlation analysis, y = -0.0331 + 1.016x in Passing Bablok regression analysis (95% confidence intervals between slope 1.0044-1.0275, intercept -0.1031 –0.0492 found.); For hemoglobin; r = 0.998 (p <0.0001) in correlation analysis, y = 0.0688525 + 1.0164x in Passing Bablok regression analysis (95% confidence intervals between slope 1.0000- 1.0274, intercept -0.04589 – 0.3000 found.); For Platelet; r = 0.988 (p <0.0001) in correlation analysis, y = 4.2923 + 0.9692x in Passing-Bablok regression analysis (95% confidence intervals between slope 0.9462-0.9935, intercept -1.3366 – 9.8226 found.); For neutrophil; r = 0.995 (p <0.0001) in correlation analysis, y = 0.06362 + 1.0328x in Passing Bablok regression analysis (95% confidence intervals between slope 1.0221-1.0498, intercept -0.002711 – 0,1103 found.); For lymphocyte; r = 0.990 (p <0.0001) in correlation analysis, y = -0.0100 + 1.0000x in Passing-Bablok regression analysis (95% confidence intervals between slope 0.985-1.0152, intercept -0.03621 – -0.02688 found.); For immature granulocyte; r = 0.903 (p <0.0001) in correlation analysis, y = -0.007647 + 0.8824x in Passing Bablok regression analysis (95% confidence intervals between slope 0.7727-1.0000, intercept -0,01000 – -0,05455 found) CONCLUSIONS: It has been shown that the intercept and slope values obtained as a result of the Passing Bablok regression analysis are within 95% confidence interval and 95% of the data in the Bland-Altman graph is within ± 1.96SD. It has been shown that the hemogram device newly installed in our laboratory is statistically compatible with the device we use routinely. [ABSTRACT FROM AUTHOR]
- Published
- 2020