1. Automatic intracranial abnormality detection and localization in head CT scans by learning from free-text reports.
- Author
-
Liu A, Guo Y, Lyu J, Xie J, Xu F, Lou X, Yong JH, and Dai Q
- Subjects
- Area Under Curve, ROC Curve, Tomography, X-Ray Computed
- Abstract
Deep learning has yielded promising results for medical image diagnosis but relies heavily on manual image annotations, which are expensive to acquire. We present Cross-DL, a cross-modality learning framework for intracranial abnormality detection and localization in head computed tomography (CT) scans by learning from free-text imaging reports. Cross-DL has a discretizer that automatically extracts discrete labels of abnormality types and locations from reports, which are utilized to train an image analyzer by a dynamic multi-instance learning approach. Benefiting from the low annotation cost and a consequent large-scale training set of 28,472 CT scans, Cross-DL achieves accurate performance, with an average area under the receiver operating characteristic curve (AUROC) of 0.956 (95% confidence interval: 0.952-0.959) in detecting 4 abnormality types in 17 regions while accurately localizing abnormalities at the voxel level. An intracranial hemorrhage classification experiment on the external dataset CQ500 achieves an AUROC of 0.928 (0.905-0.951). The model can also help review prioritization., Competing Interests: Declaration of interests The authors declare no competing interests., (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF