1. Randomised controlled trial to assess the effect of a Just-in-Time training on procedural performance: a proof-of-concept study to address procedural skill decay.
- Author
-
Branzetti JB, Adedipe AA, Gittinger MJ, Rosenman ED, Brolliar S, Chipman AK, Grand JA, and Fernandez R
- Subjects
- Adult, Checklist, Computer Simulation, Female, Humans, Male, Middle Aged, Pacemaker, Artificial, Prospective Studies, Time Factors, Cardiovascular Surgical Procedures education, Clinical Competence, Emergency Medicine education
- Abstract
Background: A subset of high-risk procedures present significant safety threats due to their (1) infrequent occurrence, (2) execution under time constraints and (3) immediate necessity for patient survival. A Just-in-Time (JIT) intervention could provide real-time bedside guidance to improve high-risk procedural performance and address procedural deficits associated with skill decay., Objective: To evaluate the impact of a novel JIT intervention on transvenous pacemaker (TVP) placement during a simulated patient event., Methods: This was a prospective, randomised controlled study to determine the effect of a JIT intervention on performance of TVP placement. Subjects included board-certified emergency medicine physicians from two hospitals. The JIT intervention consisted of a portable, bedside computer-based procedural adjunct. The primary outcome was performance during a simulated patient encounter requiring TVP placement, as assessed by trained raters using a technical skills checklist. Secondary outcomes included global performance ratings, time to TVP placement, number of critical omissions and System Usability Scale scores (intervention only)., Results: Groups were similar at baseline across all outcomes. Compared with the control group, the intervention group demonstrated statistically significant improvement in the technical checklist score (11.45 vs 23.44, p<0.001, Cohen's d effect size 4.64), the global rating scale (2.27 vs 4.54, p<0.001, Cohen's d effect size 3.76), and a statistically significant reduction in critical omissions (2.23 vs 0.68, p<0.001, Cohen's d effect size -1.86). The difference in time to procedural completion was not statistically significant between conditions (11.15 min vs 12.80 min, p=0.12, Cohen's d effect size 0.65). System Usability Scale scores demonstrated excellent usability., Conclusion: A JIT intervention improved procedure perfromance, suggesting a role for JIT interventions in rarely performed procedures., Competing Interests: Competing interests: RF, EDR received funds from Physio-Control for scientific research unrelated to this project., (© Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.)
- Published
- 2017
- Full Text
- View/download PDF