3 results on '"Rana, Zaker"'
Search Results
2. Sexual, irritative, and voiding outcomes, following stereotactic body radiation therapy for prostate cancer.
- Author
-
Rana, Zaker, Hong, Robert L., Abugideiri, Mustafa, McRae, Donald, Cernica, George, Mordkin, Robert, Joel, Andrew B., Bernstein, Gregory, and Nasr, Nadim M.
- Subjects
- *
PROSTATE cancer treatment , *STEREOTACTIC radiotherapy , *HEALTH outcome assessment , *CANCER radiotherapy , *SYMPTOMS , *SEXUAL dysfunction - Abstract
Background: Urinary symptoms and sexual dysfunction are the two most common complaints following prostate radiotherapy. The impact of hypofractionated treatment on sexual function, irritative symptoms, and voiding symptoms has not been determined within the same patient population. Here we present our institutional data on sexual function, voiding function, irritative symptoms, and treatment response following SBRT. Methods: This retrospective analysis includes 102 non-metastatic patients treated with SBRT at a single institution between May 2008 and September 2014. The course of radiotherapy consisted of 36.25 Gy (range 35-40) over five daily fractions. International Prostate Symptom Score (IPSS), Sexual Health Inventory for Men (SHIM), and PSA were recorded at baseline, 1, 3, 6, 9, 12, 18, 24, and 36 months after treatment. Results: Median patient age was 72 years old with a median follow-up of 4.3 years. Pretreatment IPSS-I score was 5.21, increasing to 6.97 (p < .001) after 1 month. The mean IPSS-I score returned close to baseline after 3 months to 5.86 and decreased to below baseline after 2 years to 5.09. At 3 months, 9 months, and 2 years, 47.5, 76.2, and 91.1 % of patients had reached IPSS-I resolution. The mean IPSS-O score prior to treatment was 5.31 and there was an increase in the score to 6.45 (p = 0.344) at 1 month. The score remained close to baseline and decreased to 4.00 at 2 years and significantly decreased to 3.74 (p = 0.035) at 3 years. 64.4, 82.1, and 96.0 % of patients had IPSS-O resolution by 3 months, 9 months, and 2 years. The mean SHIM score prior to treatment was 13.52 and continually decreased to below baseline a year after treatment to 10.56 (p < .001). SHIM score began to improve at 18 months, but was still significantly less than baseline at 12.12 (p = .01). Conclusions: While an increase in AUA/IPSS score initially occurred, all patients resume normal activities immediately following treatment and the AUA/IPSS symptoms improved from baseline. Irittative symptoms take longer to resolve when compared to obstructive voiding symptoms in patients treated with SBRT. Three year PSA response, reported toxicity, erectile function preservation, and urinary function improvement, shows favorable results. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
3. Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes.
- Author
-
Rana, Zaker, Nasr, Nadim M., Ji, Huaying, Lorio, Virginia, Akbari, Stephanie, Sebastian, Molly, Martin, Mami, and Hong, Robert L.
- Subjects
- *
RADIATION dosimetry , *CATHETERS , *BREAST cancer treatment , *TOXICITY testing , *RETROSPECTIVE studies - Abstract
Purpose: Accelerated partial breast irradiation (APBI) with balloon and strut adjusted volume implants (SAVI) show promising results with excellent tumor control and minimal toxicity. Knowing the factors that contribute to a high skin dose, rib dose, and D95 coverage may reduce toxicity, improve tumor control, and help properly predict patient outcomes following APBI. Methods and materials: A retrospective analysis of 594 patients treated with brachytherapy based APBI at a single institution from May 2008 to September 2014 was grouped by applicator subtype. Patients were treated to a total of 34 Gy (3.4 Gy x 10 fractions over 5 days delivered BID) targeting a planning target volume (PTV) 1.0 cm beyond the lumpectomy cavity using a high dose rate source. Results: SAVI devices had the lowest statistically significant values of DmaxSkin (81.00 ± 29.83), highest values of D90 (101.50 ± 3.66), and D95 (96.09 ± 4.55). SAVI-mini devices had the lowest statistically significant values of DmaxRib (77.66 ± 32.92) and smallest V150 (18.01 ± 3.39). Multi-lumen balloons were able to obtain the smallest V200 (5.89 ± 2.21). Strut-based applicators were more likely to achieve a DmaxSkin and a DmaxRib less than or equal to 100 %. The effect of PTV on V150 showed a strong positive relationship (p < .001). PTV and DmaxSkin showed a weak negative relationship in multi-lumen applicators (p = .016) and SAVI-mini devices (p < .001). PTV and DmaxRib showed a weak negative relationship in multi-lumen applicators (p = .009), SAVI devices (p < .001), and SAVI-mini devices (p < .001). Conclusion: PTV volume is strongly correlated with V150 in all devices and V200 in strut based devices. Larger PTV volumes result in greater V150 and V200, which could help predict potential risks for hotspots and resulting toxicities in these devices. PTV volume is also weakly negatively correlated with max skin dose and max rib dose, meaning that as the PTV volumes increase one can expect slightly smaller max skin and rib doses. Strut based applicators are significantly more effective in keeping skin and rib dose constraints under 125 and 100 % when compared to any balloon based applicator. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.