1. Dual-energy CT Aortography with 50% Reduced Iodine Dose Versus Single-energy CT Aortography with Standard Iodine Dose.
- Author
-
Shuman WP, Chan KT, Busey JM, Mitsumori LM, and Koprowicz KM
- Subjects
- Aged, Aged, 80 and over, Aorta diagnostic imaging, Female, Humans, Image Processing, Computer-Assisted methods, Iohexol administration & dosage, Male, Middle Aged, Prospective Studies, Radiographic Image Enhancement methods, Signal-To-Noise Ratio, Triiodobenzoic Acids administration & dosage, Aortography methods, Computed Tomography Angiography methods, Contrast Media administration & dosage, Iodine administration & dosage, Radiation Dosage, Radiography, Dual-Energy Scanned Projection methods
- Abstract
Rationale and Objectives: Because many patients with aortic pathology also have compromised renal function, we wished to investigate dual-energy computed tomography (DECT) aortography with 50% reduced iodine dose compared to single-energy computed tomography (SECT) aortography with standard iodine dose., Materials and Methods: Fifty patients had DECT aortography with 50% reduced iodine dose. Thirty-four of these patients had prior SECT aortography with standard iodine dose. DECT images were reconstructed at both 50 and 77 keV and were compared to SECT 120 kVp images. Reviewers measured aortic attenuation, image noise, and scored vascular enhancement. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Volume CT dose index was recorded., Results: Mean iodine dose was 47 g for SECT and 24 g for DECT. Aortic attenuation was highest at reduced iodine dose DECT 50 keV (570 ± 105 Hounsfield units [HU]) compared to 77 keV (239 ± 40 HU) or to standard iodine dose SECT 120 kVp (356 ± 69 HU) (P < 0.05). Image noise was greatest at 50 keV compared to 77 keV and 120 kVp (P < 0.05) but was similar between 77 keV and 120 kVp (P > 0.05). SNR and CNR were the same at 50 keV and 120 kVp (P > 0.05). Mean vascular enhancement scores were all above 3.0 (good, typical enhancement). Volume CT dose index was 11.7 mGy for DECT and 11.8 mGy for SECT (P = 0.37)., Conclusions: DECT aortography with 50% reduced iodine reconstructed at 50 keV resulted in significantly greater aortic attenuation, good subjective vascular enhancement, and comparable SNR and CNR compared to standard iodine dose SECT. DECT image noise at 77 keV was similar to SECT at 120 kVp., (Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF