1. A study on energy resolution of CANDLES detector
- Author
-
Y. Tamagawa, H. Hiraoka, K. Nakajima, Ken-Ichi Fushimi, M. Tsuzuki, Masaharu Nomachi, Saori Umehara, B. T. Khai, Sei Yoshida, S. Ajimura, Tadafumi Kishimoto, Toshihiro Maeda, M. Tozawa, Y. Takihira, Y. Takemoto, W. M. Chan, K. Kanagawa, Ryuta Hazama, T. Ohata, Takashi Iida, K. Suzuki, Izumi Ogawa, and H. Kino
- Subjects
Physics ,Nuclear and High Energy Physics ,Photomultiplier ,Photon ,Physics - Instrumentation and Detectors ,Physics::Instrumentation and Detectors ,010308 nuclear & particles physics ,FOS: Physical sciences ,Instrumentation and Detectors (physics.ins-det) ,Scintillator ,01 natural sciences ,Photon counting ,High Energy Physics - Experiment ,Nuclear physics ,High Energy Physics - Experiment (hep-ex) ,Nuclear Energy and Engineering ,0103 physical sciences ,Sensitivity (control systems) ,Electrical and Electronic Engineering ,Neutrino ,Exponential decay ,Nuclear Experiment (nucl-ex) ,Nuclear Experiment ,Energy (signal processing) - Abstract
In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0\nu\beta\beta$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($\sigma_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $\sigma_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $\sigma_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $\sigma_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($\gamma$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($\gamma$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0\nu\beta\beta$ half-life of $^{48}$Ca can be improved by 1.09 times., Comment: This manuscript is prepared for submission to IEEE Transaction on Nuclear Science. It contains 11 pages, 19 figures, and 1 table
- Published
- 2020
- Full Text
- View/download PDF