1. Development of an n-channel CCD, CCD-NeXT1, for Soft X-ray Imager onboard the NeXT satellite
- Author
-
Hiroshi Tsunemi, Takeshi Go Tsuru, Kentaro Maeda, Hironori Matsumoto, Shin-ichiro Takagi, Kazuhisa Miyaguchi, Emi Miyata, Masakuni Tohiguchi, Tatsuya Inui, H. Ozawa, Daisuke Matsuura, Katsuji Koyama, and Hirohiko Kohno
- Subjects
Physics ,Nuclear and High Energy Physics ,business.industry ,Detector ,Astrophysics (astro-ph) ,Polishing ,FOS: Physical sciences ,Astrophysics ,Noise (electronics) ,law.invention ,Telescope ,Imaging spectroscopy ,Full width at half maximum ,Optics ,Depletion region ,law ,Optoelectronics ,Wafer ,business ,Instrumentation - Abstract
NeXT (New X-ray Telescope) is the next Japanese X-ray astronomical satellite mission after the Suzaku satellite. NeXT aims to perform wide band imaging spectroscopy. Due to the successful development of a multilayer coated mirror, called a supermirror, NeXT can focus X-rays in the energy range from 0.1 keV up to 80 keV. To cover this wide energy range, we are in the process of developing a hybrid X-ray camera, Wideband X-ray Imager (WXI) as a focal plane detector of the supermirror. The WXI consists of X-ray CCDs (SXI) and CdTe pixelized detectors (HXI), which cover the lower and higher X-ray energy bands of 0.1-80 keV, respectively. The X-ray CCDs of the SXI are stacked above the CdTe pixelized detectors of the HXI. The X-ray CCDs of the SXI detect soft X-rays below $\sim$ 10 keV and allow hard X-rays pass into the CdTe detectors of the HXI without loss. Thus, we have been developing a "back-supportless CCD" with a thick depletion layer, a thinned silicon wafer, and a back-supportless structure. In this paper, we report the development and performances of an evaluation model of CCD for the SXI, "CCD-NeXT1". We successfully fabricated two types of CCD-NeXT1, unthinned CCDs with 625-um thick wafer and 150-um thick thinned CCDs. By omitting the polishing process when making the thinned CCDs, we confirmed that the polishing process does not impact the X-ray performance. In addition, we did not find significant differences in the X-ray performance between the two types of CCDs. The energy resolution and readout noise are $\sim$ 140 eV (FWHM) at 5.9 keV and $\sim$5 electrons (RMS), respectively. The estimated thickness of the depletion layer is $\sim$80 um. The performances almost satisfy the requirements of the baseline plan of the SXI., Comment: 20 pages, 10 figures, Accepted for publication in NIMA
- Published
- 2007
- Full Text
- View/download PDF