1. Thermal and Mechanical Analysis on the Cold Mass Support Assembly of Test Cryomodule for IMP ADSInjector- II.
- Author
-
Guo, X. L., Wang, L., Wang, J., Wang, S. Y., Liu, Y. Y., and Sun, S.
- Subjects
- *
ACCELERATOR-driven systems , *SUPERCONDUCTING device testing , *INJECTORS , *SUPERCONDUCTING cavity resonators , *SUPERCONDUCTING magnets , *THERMAL stresses - Abstract
The Injector-II of ADS project will include two cryomodules, each of which consists of eight HWR cavities and nine SC solenoid magnets. A test cryomodule (TCM1) containing one HWR cavity and two SC magnets was developed for verification of related technique at the first stage. The TCM1 cryostat was designed by Shanghai Institute of Applied Physics of Chinese Academy of Sciences (SINAP, CAS). The cold mass support assembly in the test cryomodule should accommodate the unbalanced loads induced by each cold mass assembly, the deformation induced by thermal shrinkage, and the thermal stress between different materials. In order to validate the structure design, coupled thermal and mechanical analysis on the cold mass support assembly was performed. The temperature, deformation and stress of the cold mass support assembly were obtained. The results effectively provide the guideline for the design and improvement of the cold mass support assembly. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF