Neonicotinoids (NEOs), used as insecticides against aphids, whiteflies, lepidopterans, and beetles, have numerous detrimental impacts on human health, including chronic illnesses, cancer, infertility, and birth anomalies. Monitoring the residues in food products is necessary to guarantee public health and ecological balance. The present work validated a new method to measure seven neonicotinoid insecticides (acetamiprid ACT, clothianidin CLT, dinotefuran DNT, imidacloprid IMD, nitenpyram NTP, thiacloprid TCP, and thiamethoxan THT) in wheat. The analytical procedure was based on simple and fast wheat sample cleanup using solid-phase extraction (SPE) to remove interferents and enrich the NEOs, alongside the NEOs' separation and quantification by reverse-phase chromatography coupled with a diode array detector (DAD). The validation process was validated using the accuracy profile strategy, a straightforward decision tool based on the measure of the total error (bias plus standard deviation) of the method. Our results proved that, in the future, at least 95% of the results obtained with the proposed method would fall within the ±15% acceptance limits. The test's cost-effectiveness, rapidity, and simplicity suggest its use for determining the levels of acetamiprid, clothianidin, dinotefuran, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam in routine analyses of wheat. [ABSTRACT FROM AUTHOR]