1. Complications related to third space endoscopic procedures.
- Author
-
El Abiad R, Ashat M, and Khashab M
- Subjects
- Humans, Risk Factors, Myotomy adverse effects, Myotomy methods, Postoperative Complications etiology, Insufflation adverse effects, Gastroesophageal Reflux surgery, Gastroesophageal Reflux diagnosis, Natural Orifice Endoscopic Surgery adverse effects
- Abstract
Third space endoscopy (TSE) encompasses a breadth of procedures for the treatment of a variety of GI disorders. The widespread use of per-oral endoscopic myotomy (POEM) and its diversification to include extended indications and at locations other than the oesophagus has provided an insight into the potential complications encountered. The most common adverse events associated with POEM, the epitome of TSE procedures, include insufflation related injuries, bleeding, failure of mucosal barrier, infections, pain, blown out myotomy and gastroesophageal reflux disease. The purpose of this review is to highlight the pitfalls and to identify the risk factors that may lead to adverse events, and to recommend appropriate salvage interventions in the scope of the current evidence., Competing Interests: Declaration of competing interest Mouen Khashab: consultant for Boston Scientific, Olympus, and Medtronic. Rami El Abiad: none. Munish Ashat: none., (Copyright © 2024 Elsevier Ltd. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF