7 results on '"Pucher, Elsa"'
Search Results
2. Registro Italiano pacemaker e defibrillatori bollettino periodico 2015: Associazione Italiana di Aritmologia e Cardiostimolazione
- Author
-
Proclemer, Alessandro, Zecchin, Massimo, D'Onofrio, Antonio, Boriani, Giuseppe, Botto, Giovanni Luca, Facchin, Domenico, Rebellato, Luca, Ghidina, Marco, Bianco, Giulia, Bernardelli, Emanuela, Pucher, Elsa, and Gregori, Dario
- Subjects
Adult ,Male ,Time Factors ,Adolescent ,Cardiology ,Arrhythmias ,Risk Factors ,Medical ,Surveys and Questionnaires ,80 and over ,Humans ,Implantable defibrillator ,Registries ,Child ,Pacemaker ,Aged ,Aged, 80 and over ,Arrhythmias, Cardiac ,Defibrillators, Implantable ,Female ,Italy ,Middle Aged ,Pacemaker, Artificial ,Societies, Medical ,Treatment Outcome ,Guideline Adherence ,Patient Selection ,Cardiology and Cardiovascular Medicine ,Artificial ,Implantable ,Societies ,Cardiac ,Defibrillators - Published
- 2017
3. [The Pacemaker and Implantable Cardioverter-Defibrillator Registry of the Italian Association of Arrhythmology and Cardiac Pacing - Annual report 2016].
- Author
-
Proclemer A, Zecchin M, D'Onofrio A, Boriani G, Facchin D, Rebellato L, Ghidina M, Bianco G, Bernardelli E, Pucher E, and Gregori D
- Subjects
- Aged, Aged, 80 and over, Arrhythmias, Cardiac epidemiology, Arrhythmias, Cardiac physiopathology, Electrocardiography, Female, Humans, Italy, Male, Middle Aged, Primary Prevention statistics & numerical data, Registries, Secondary Prevention statistics & numerical data, Societies, Medical, Arrhythmias, Cardiac therapy, Cardiac Resynchronization Therapy statistics & numerical data, Defibrillators, Implantable statistics & numerical data, Pacemaker, Artificial statistics & numerical data
- Abstract
Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2016 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers., Methods: The registry collects prospectively national PM and ICD implantation activity on the basis of European cards., Results: PM Registry: data about 23 496 PM implantations were collected (19 003 first implant and 4493 replacements). The number of collaborating centers was 204. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 39.8% of first PM implants, sick sinus syndrome in 22.1%, atrial fibrillation plus bradycardia in 14.1%, other in 24.0%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (22.18% of first implants). Use of single-chamber PMs was reported in 26.9% of first implants, of dual-chamber PMs in 65.0%, of PMs with cardiac resynchronization therapy (CRT) in 1.5%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 6.6%. ICD Registry: data about 20 350 ICD implantations were collected (14 763 first implants and 5587 replacements). The number of collaborating centers was 430. Median age of treated patients was 72 years (63 quartile I; 78 quartile III]. Primary prevention indication was reported in 79.0% of first implants, secondary prevention in 21.0% (cardiac arrest in 7.9%). A single-chamber ICD was used in 32.2% of first implants, dual-chamber in 31.1% and biventricular in 36.7%., Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a large use of prophylactic and biventricular ICD, reflecting a favorable adherence to trials and guidelines in clinical practice.
- Published
- 2018
- Full Text
- View/download PDF
4. [The Pacemaker and Implantable Cardioverter-Defibrillator Registry of the Italian Association of Arrhythmology and Cardiac Pacing - Annual report 2015].
- Author
-
Proclemer A, Zecchin M, D'Onofrio A, Boriani G, Botto GL, Facchin D, Rebellato L, Ghidina M, Bianco G, Bernardelli E, Pucher E, and Gregori D
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Arrhythmias, Cardiac physiopathology, Child, Female, Humans, Italy, Male, Middle Aged, Registries, Risk Factors, Societies, Medical, Surveys and Questionnaires, Time Factors, Treatment Outcome, Arrhythmias, Cardiac therapy, Cardiology, Defibrillators, Implantable statistics & numerical data, Guideline Adherence, Pacemaker, Artificial statistics & numerical data, Patient Selection
- Abstract
Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2015 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers., Methods: The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards., Results: PM Registry: data about 24 285 PM implantations were collected (19 194 first implant and 5091 replacements). The number of collaborating centers was 218. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 42.8% of first PM implants, sick sinus syndrome in 22.9%, atrial fibrillation plus bradycardia in 15.1%, other in 19.2%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.8% of first implants). Use of single-chamber PMs was reported in 26.9% of first implants, of dual-chamber PMs in 63.4%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 7.9%. ICD Registry: data about 15 363 ICD implantations were collected (11 453 first implants and 3910 replacements). The number of collaborating centers was 434. Median age of treated patients was 71 years (63 quartile I; 78 quartile III]. Primary prevention indication was reported in 77.3% of first implants, secondary prevention in 22.7% (cardiac arrest in 8.0%). A single-chamber ICD was used in 29.3% of first implants, dual-chamber in 34.6% and biventricular in 36.1%., Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a large use of prophylactic and biventricular ICD, reflecting a favorable adherence to trials and guidelines in clinical practice.
- Published
- 2017
- Full Text
- View/download PDF
5. [The Pacemaker and Implantable Cardioverter-Defibrillator Registry of the Italian Association of Arrhythmology and Cardiac Pacing--Annual report 2014].
- Author
-
Proclemer A, Zecchin M, D'Onofrio A, Botto GL, Facchin D, Rebellato L, Ghidina M, Bianco G, Bernardelli E, Pucher E, and Gregori D
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Cardiology, Child, Female, Humans, Italy, Male, Middle Aged, Societies, Medical, Young Adult, Defibrillators, Implantable statistics & numerical data, Pacemaker, Artificial statistics & numerical data, Registries
- Abstract
Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2014 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers., Methods: The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards., Results: PM Registry: data about 24 680 PM implantations were collected (19 480 first implant and 5200 replacements). The number of collaborating centers was 208. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 45.3% of first PM implants, sick sinus syndrome in 23.1%, atrial fibrillation plus bradycardia in 11.7%, other in 19.9%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (22.7% of first implants). Use of single-chamber PMs was reported in 26.9% of first implants, of dual-chamber PMs in 63.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.7%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 7.8%. ICD Registry: data about 17 116 ICD implantations were collected (11 274 first implants and 5842 replacements). The number of collaborating centers was 424. Median age of treated patients was 71 years (62 quartile I; 77 quartile III). Primary prevention indication was reported in 72.3% of first implants, secondary prevention in 27.7% (cardiac arrest in 10.1%). A single-chamber ICD was used in 32.2% of first implants, dual-chamber in 37.1% and biventricular in 30.7%., Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a large use of prophylactic and biventricular ICD, reflecting a favorable adherence to trials and guidelines in clinical practice.
- Published
- 2016
- Full Text
- View/download PDF
6. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].
- Author
-
Proclemer A, Zecchin M, D'Onofrio A, Botto GL, Rebellato L, Ghidina M, Bianco G, Bernardelli E, Pucher E, and Gregori D
- Subjects
- Aged, Aged, 80 and over, Arrhythmias, Cardiac physiopathology, Cooperative Behavior, Guideline Adherence, Humans, Italy, Middle Aged, Practice Guidelines as Topic, Registries, Societies, Medical, Arrhythmias, Cardiac therapy, Defibrillators, Implantable statistics & numerical data, Pacemaker, Artificial statistics & numerical data
- Abstract
Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers., Methods: The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards., Results: PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%., Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a constant increase in prophylactic and biventricular ICD use, reflecting a favorable adherence to trials and guidelines in clinical practice.
- Published
- 2014
- Full Text
- View/download PDF
7. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association of Arrhythmology and Cardiac Pacing - Annual Report 2012].
- Author
-
Proclemer A, Zecchin M, Lunati M, Rebellato L, Ghidina M, Bianco G, Bernardelli E, Pucher E, and Gregori D
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Female, Humans, Italy, Male, Middle Aged, Societies, Medical, Young Adult, Defibrillators, Implantable statistics & numerical data, Pacemaker, Artificial statistics & numerical data, Registries
- Abstract
Background: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2012 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers., Methods: The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards., Results: PM Registry: data about 25 611 PM implantations were collected (18 870 first implant and 6741 replacements). The number of collaborating centers was 245. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 41.9% of first PM implants, sick sinus syndrome in 26.0%, atrial fibrillation plus bradycardia in 13.7%, other in 18.4%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (21.7% of first implants). Use of single-chamber PMs was reported in 29.0% of first implants, of dual-chamber PMs in 61.3%, of PMs with cardiac resynchronization therapy (CRT) in 1.7%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.0%. ICD REGISTRY: data about 16 606 ICD implantations were collected (11 393 first implants and 5213 replacements). The number of collaborating centers was 427. Median age of treated patients was 71 years (62 quartile I; 77 quartile III). Primary prevention indication was reported in 68.6% of first implants, secondary prevention in 31.4% (cardiac arrest in 9.0%). A single-chamber ICD was used in 29.4% of first implants, dual-chamber in 37.6% and biventricular in 32.9%., Conclusions: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a constant increase in prophylactic and biventricular ICD use, reflecting a favorable adherence to trials and guidelines in clinical practice.
- Published
- 2013
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.