1. A 3D and Explainable Artificial Intelligence Model for Evaluation of Chronic Otitis Media Based on Temporal Bone Computed Tomography: Model Development, Validation, and Clinical Application
- Author
-
Binjun Chen, Yike Li, Yu Sun, Haojie Sun, Yanmei Wang, Jihan Lyu, Jiajie Guo, Shunxing Bao, Yushu Cheng, Xun Niu, Lian Yang, Jianghong Xu, Juanmei Yang, Yibo Huang, Fanglu Chi, Bo Liang, and Dongdong Ren
- Subjects
Computer applications to medicine. Medical informatics ,R858-859.7 ,Public aspects of medicine ,RA1-1270 - Abstract
BackgroundTemporal bone computed tomography (CT) helps diagnose chronic otitis media (COM). However, its interpretation requires training and expertise. Artificial intelligence (AI) can help clinicians evaluate COM through CT scans, but existing models lack transparency and may not fully leverage multidimensional diagnostic information. ObjectiveWe aimed to develop an explainable AI system based on 3D convolutional neural networks (CNNs) for automatic CT-based evaluation of COM. MethodsTemporal bone CT scans were retrospectively obtained from patients operated for COM between December 2015 and July 2021 at 2 independent institutes. A region of interest encompassing the middle ear was automatically segmented, and 3D CNNs were subsequently trained to identify pathological ears and cholesteatoma. An ablation study was performed to refine model architecture. Benchmark tests were conducted against a baseline 2D model and 7 clinical experts. Model performance was measured through cross-validation and external validation. Heat maps, generated using Gradient-Weighted Class Activation Mapping, were used to highlight critical decision-making regions. Finally, the AI system was assessed with a prospective cohort to aid clinicians in preoperative COM assessment. ResultsInternal and external data sets contained 1661 and 108 patients (3153 and 211 eligible ears), respectively. The 3D model exhibited decent performance with mean areas under the receiver operating characteristic curves of 0.96 (SD 0.01) and 0.93 (SD 0.01), and mean accuracies of 0.878 (SD 0.017) and 0.843 (SD 0.015), respectively, for detecting pathological ears on the 2 data sets. Similar outcomes were observed for cholesteatoma identification (mean area under the receiver operating characteristic curve 0.85, SD 0.03 and 0.83, SD 0.05; mean accuracies 0.783, SD 0.04 and 0.813, SD 0.033, respectively). The proposed 3D model achieved a commendable balance between performance and network size relative to alternative models. It significantly outperformed the 2D approach in detecting COM (P≤.05) and exhibited a substantial gain in identifying cholesteatoma (P
- Published
- 2024
- Full Text
- View/download PDF