9 results on '"Moerman KM"'
Search Results
2. A clinical comparison of a digital versus conventional design methodology for transtibial prosthetic interfaces.
- Author
-
Lee DRC, Yang X, Riccio-Ackerman F, Alemón B, Ballesteros-Escamilla M, Solav D, Lipsitz SR, Moerman KM, Meyer CI, Jaeger AM, Huegel JC, and Herr HM
- Subjects
- Humans, Male, Female, Adult, Amputees rehabilitation, Middle Aged, Gait physiology, Walking physiology, Artificial Limbs, Prosthesis Design methods, Tibia surgery, Tibia diagnostic imaging
- Abstract
A transtibial prosthetic interface typically comprises a compliant liner and an outer rigid socket. The preponderance of today's conventional liners are mass produced in standard sizes, and conventional socket design is labor-intensive and artisanal, lacking clear scientific rationale. This work tests the clinical efficacy of a novel, physics-based digital design framework to create custom prosthetic liner-socket interfaces. In this investigation, we hypothesize that the novel digital approach will improve comfort outcomes compared to a conventional method of liner-socket design. The digital design framework generates custom transtibial prosthetic interfaces starting from MRI or CT image scans of the residual limb. The interface design employs FEA to simulate limb deformation under load. Interfaces are fabricated for 9 limbs from 8 amputees (1 bilateral). Testing compares novel and conventional interfaces across four assessments: 5-min walking trial, thermal imaging, 90-s standing pressure trial, and an evaluation questionnaire. Outcome measures include antalgic gait criterion, skin surface pressures, skin temperature changes, and direct questionnaire feedback. Antalgic gait is compared via a repeated measures linear mixed model while the other assessments are compared via a non-parametric Wilcoxon sign-rank test. A statistically significant ([Formula: see text]) decrease in pain is demonstrated when walking on the novel interfaces compared to the conventional. Standing pressure data show a significant decrease in pressure on novel interfaces at the anterior distal tibia ([Formula: see text]), with no significant difference at other measured locations. Thermal results show no statistically significant difference related to skin temperature. Questionnaire feedback shows improved comfort on novel interfaces on posterior and medial sides while standing and the medial side while walking. Study results support the hypothesis that the novel digital approach improves comfort outcomes compared to the evaluated conventional method. The digital interface design methodology also has the potential to provide benefits in design time, repeatability, and cost., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
3. 3D Ultrasound Shear Wave Elastography for Musculoskeletal Tissue Assessment Under Compressive Load: A Feasibility Study.
- Author
-
Ranger BJ, Moerman KM, Feigin M, Herr HM, and Anthony BW
- Subjects
- Humans, Elasticity Imaging Techniques methods, Feasibility Studies, Phantoms, Imaging, Imaging, Three-Dimensional methods
- Abstract
Given its real-time capability to quantify mechanical tissue properties, ultrasound shear wave elastography holds significant promise in clinical musculoskeletal imaging. However, existing shear wave elastography methods fall short in enabling full-limb analysis of 3D anatomical structures under diverse loading conditions, and may introduce measurement bias due to sonographer-applied force on the transducer. These limitations pose numerous challenges, particularly for 3D computational biomechanical tissue modeling in areas like prosthetic socket design. In this feasibility study, a clinical linear ultrasound transducer system with integrated shear wave elastography capabilities was utilized to scan both a calibrated phantom and human limbs in a water tank imaging setup. By conducting 2D and 3D scans under varying compressive loads, this study demonstrates the feasibility of volumetric ultrasound shear wave elastography of human limbs. Our preliminary results showcase a potential method for evaluating 3D spatially varying tissue properties, offering future extensions to computational biomechanical modeling of tissue for various clinical scenarios., Competing Interests: Declaration of Conflicting InterestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
- Published
- 2024
- Full Text
- View/download PDF
4. Experimental and computational analysis of energy absorption characteristics of three biomimetic lattice structures under compression.
- Author
-
Vafaeefar M, Moerman KM, and Vaughan TJ
- Subjects
- Humans, Finite Element Analysis, Physical Phenomena, Biomimetics
- Abstract
The objective of this study is to evaluate the mechanical properties and energy absorption characteristics of the gyroid, dual-lattice and spinodoid structures, as biomimetic lattices, through finite element analysis and experimental characterisation. As part of the study, gyroid and dual-lattice structures at 10% volume fraction were 3D-printed using an elastic resin, and mechanically tested under uniaxial compression. Computational models were calibrated to the observed experimental data and the response of higher volume fraction structures were simulated in an explicit finite element solver. Stress-strain data of groups of lattices at different volume fractions were studied and energy absorption parameters including total energy absorbed per unit volume, energy absorption efficiency and onset of densification strain were calculated. Also, the structures were characterized into bending-dominant and stretch-dominant structures, according to their nodal connectivity and Gibson-and-Ashby's law. The results of the study showed that the dual-lattice is capable of absorbing more energy at each volume fraction cohort. However, gyroid structures showed higher energy absorption efficiency and the onset of densification at higher strains. The spinodoid structure was found to be the poorest structure in terms of energy absorption, specifically at low volume fractions. Also, the results showed that the dual-lattice was a stretch dominated structure, while the gyroid structure was a bending dominated structure, which may be a reason that it is a better candidate for energy absorption applications., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023 Elsevier Ltd. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
5. Biomechanical Characterisation of Thoracic Ascending Aorta with Preserved Pre-Stresses.
- Author
-
Parikh S, Moerman KM, Ramaekers MJFG, Schalla S, Bidar E, Delhaas T, Reesink K, and Huberts W
- Abstract
Mechanical properties of an aneurysmatic thoracic aorta are potential markers of future growth and remodelling and can help to estimate the risk of rupture. Aortic geometries obtained from routine medical imaging do not display wall stress distribution and mechanical properties. Mechanical properties for a given vessel may be determined from medical images at different physiological pressures using inverse finite element analysis. However, without considering pre-stresses, the estimation of mechanical properties will lack accuracy. In the present paper, we propose and evaluate a mechanical parameter identification technique, which recovers pre-stresses by determining the zero-pressure configuration of the aortic geometry. We first validated the method on a cylindrical geometry and subsequently applied it to a realistic aortic geometry. The verification of the assessed parameters was performed using synthetically generated reference data for both geometries. The method was able to estimate the true mechanical properties with an accuracy ranging from 98% to 99%.
- Published
- 2023
- Full Text
- View/download PDF
6. Additively manufactured polyethylene terephthalate scaffolds for scapholunate interosseous ligament reconstruction.
- Author
-
Gomez-Cerezo MN, Perevoshchikova N, Ruan R, Moerman KM, Bindra R, Lloyd DG, Zheng MH, Saxby DJ, and Vaquette C
- Subjects
- Humans, Polyethylene Terephthalates, Ligaments, Articular surgery, Ligaments, Articular physiology, Wrist Joint, Scaphoid Bone surgery, Lunate Bone surgery
- Abstract
The regeneration of the ruptured scapholunate interosseous ligament (SLIL) represents a clinical challenge. Here, we propose the use of a Bone-Ligament-Bone (BLB) 3D-printed polyethylene terephthalate (PET) scaffold for achieving mechanical stabilisation of the scaphoid and lunate following SLIL rupture. The BLB scaffold featured two bone compartments bridged by aligned fibres (ligament compartment) mimicking the architecture of the native tissue. The scaffold presented tensile stiffness in the range of 260 ± 38 N/mm and ultimate load of 113 ± 13 N, which would support physiological loading. A finite element analysis (FEA), using inverse finite element analysis (iFEA) for material property identification, showed an adequate fit between simulation and experimental data. The scaffold was then biofunctionalized using two different methods: injected with a Gelatin Methacryloyl solution containing human mesenchymal stem cell spheroids (hMSC) or seeded with tendon-derived stem cells (TDSC) and placed in a bioreactor to undergo cyclic deformation. The first approach demonstrated high cell viability, as cells migrated out of the spheroid and colonised the interstitial space of the scaffold. These cells adopted an elongated morphology suggesting the internal architecture of the scaffold exerted topographical guidance. The second method demonstrated the high resilience of the scaffold to cyclic deformation and the secretion of a fibroblastic related protein was enhanced by the mechanical stimulation. This process promoted the expression of relevant proteins, such as Tenomodulin (TNMD), indicating mechanical stimulation may enhance cell differentiation and be useful prior to surgical implantation. In conclusion, the PET scaffold presented several promising characteristics for the immediate mechanical stabilisation of disassociated scaphoid and lunate and, in the longer-term, the regeneration of the ruptured SLIL., Competing Interests: Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Cedryck Vaquette reports financial support was provided by MTPConnect Biomedical Technology Horizons. Cedryck Vaquette reports a relationship with MTPConnect Biomedical Technology Horizons that includes: funding grants. Cedryck Vaquette, Randy Bindra have a patent #PCT/AU2018/000133 issued to U.S. Patent and Trademark Office., (Copyright © 2023 Elsevier B.V. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
7. A morphological, topological and mechanical investigation of gyroid, spinodoid and dual-lattice algorithms as structural models of trabecular bone.
- Author
-
Vafaeefar M, Moerman KM, Kavousi M, and Vaughan TJ
- Subjects
- Algorithms, Porosity, Models, Structural, Cancellous Bone, Software
- Abstract
In this study, we evaluate the performance of three algorithms as computational models of trabecular bone architecture, through systematic evaluation of morphometric, topological, and mechanical properties. Here, we consider the widely-used gyroid lattice structure, the recently-developed spinodoid structure and a structure similar to Voronoi lattices introduced here as the dual-lattice. While all computational models were calibrated to recreate the trabecular tissue volume (e.g. BV/TV), it was found that both the gyroid- and spinodoid-based structures showed substantial differences in many other morphometric and topological parameters and, in turn, showed lower effective mechanical properties compared to trabecular bone. The newly-developed dual-lattice structures better captured both morphometric parameters and mechanical properties, despite certain differences being evident their topological configuration compared to trabecular bone. Still, these computational algorithms provide useful platforms to investigate trabecular bone mechanics and for designing biomimetic structures, which could be produced through additive manufacturing for applications that include bone substitutes, scaffolds and porous implants. Furthermore, the software for the creation of the structures has been added to the open source toolbox GIBBON and is therefore freely available to the community., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2022 Elsevier Ltd. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
8. Constitutive parameter identification of transtibial residual limb soft tissue using ultrasound indentation and shear wave elastography.
- Author
-
Ranger BJ, Moerman KM, Anthony BW, and Herr HM
- Subjects
- Humans, Finite Element Analysis, Prosthesis Design, Ultrasonography, Disease Progression, Elasticity Imaging Techniques
- Abstract
Finite element analysis (FEA) can be used to evaluate applied interface pressures and internal tissue strains for computational prosthetic socket design. This type of framework requires realistic patient-specific limb geometry and constitutive properties. In recent studies, indentations and inverse FEA with MRI-derived 3D patient geometries were used for constitutive parameter identification. However, long computational times and use of specialized equipment presents challenges for clinical, deployment. In this study, we present a novel approach for constitutive parameter identification using a combination of FEA, ultrasound indentation, and shear wave elastography. Local shear modulus measurement using elastography during an ultrasound indentation experiment has particular significance for biomechanical modeling of the residual limb since there are known regional dependencies of soft tissue properties such as varying levels of scarring and atrophy. Beyond prosthesis design, this work has broader implications to the fields of muscle health and monitoring of disease progression., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2022 Elsevier Ltd. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
9. Development of a patient-specific cerebral vasculature fluid-structure-interaction model.
- Author
-
Moerman KM, Konduri P, Fereidoonnezhad B, Marquering H, van der Lugt A, Luraghi G, Bridio S, Migliavacca F, Rodriguez Matas JF, and McGarry P
- Subjects
- Computer Simulation, Hemodynamics, Humans, Models, Cardiovascular, Software, Arteries physiology, Thrombectomy
- Abstract
Development of in-silico models of patient-specific cerebral artery networks presents several significant technical challenges: (i) The resolution and smoothness of medical CT images are much lower than the required element/cell length for FEA/CFD/FSI models; (ii) contact between vessels, and indeed self contact of high tortuosity vessel segments are not clearly identifiable from medical CT images. Commercial model construction software does not provide customised solutions for such technical challenges, with the result that accurate, efficient and automated development of patient-specific models of the cerebral vessels is not facilitated. This paper presents the development of a customised and highly automated platform for the generation of high resolution patient-specific FEA/CFD/FSI models from clinical images. This platform is used to perform the first fluid-structure-interaction patient-specific analysis of blood flow and artery deformation of an occluded cerebral vessel. Results demonstrate that in addition to flow disruption, clot occlusion significantly alters the geometry and strain distribution in the vessel network, with the blocked M2 segment undergoing axial elongation. The new computational approach presented in this study can be further developed as a clinical diagnostic tool and as a platform for thrombectomy device design., (Copyright © 2021. Published by Elsevier Ltd.)
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.