14 results on '"Linzenbold W"'
Search Results
2. A new tissue-mimicking surrogate for pulmonary lesions using for RFA
- Author
-
Bühler, L, primary, Schulze, S, additional, Polke, M, additional, Kahn, N, additional, Schneider, M A, additional, Heussel, C P, additional, Herth, F J, additional, Enderle, M D, additional, and Linzenbold, W, additional
- Published
- 2022
- Full Text
- View/download PDF
3. Optimizing ureterorenoscopic biopsy quality in the upper urinary tract by cryobiopsy
- Author
-
Klein, J-T., primary, Bohnert, L., additional, Enderle, M., additional, Linzenbold, W., additional, John, A., additional, and Bolenz, C., additional
- Published
- 2022
- Full Text
- View/download PDF
4. Argon-Plasma-Coagulation (APC) zur lokalablativen Therapie des Cholangiokarzinoms
- Author
-
Genthner, A, Eickhoff, A, Albert, J, Enderle, MD, and Linzenbold, W
- Published
- 2024
- Full Text
- View/download PDF
5. Application of Deep Learning for Real-Time Ablation Zone Measurement in Ultrasound Imaging.
- Author
-
Zimmermann C, Michelmann A, Daniel Y, Enderle MD, Salkic N, and Linzenbold W
- Abstract
Background: The accurate delineation of ablation zones (AZs) is crucial for assessing radiofrequency ablation (RFA) therapy's efficacy. Manual measurement, the current standard, is subject to variability and potential inaccuracies., Aim: This study aims to assess the effectiveness of Artificial Intelligence (AI) in automating AZ measurements in ultrasound images and compare its accuracy with manual measurements in ultrasound images., Methods: An in vitro study was conducted using chicken breast and liver samples subjected to bipolar RFA. Ultrasound images were captured every 15 s, with the AI model Mask2Former trained for AZ segmentation. The measurements were compared across all methods, focusing on short-axis (SA) metrics., Results: We performed 308 RFA procedures, generating 7275 ultrasound images across liver and chicken breast tissues. Manual and AI measurement comparisons for ablation zone diameters revealed no significant differences, with correlation coefficients exceeding 0.96 in both tissues ( p < 0.001). Bland-Altman plots and a Deming regression analysis demonstrated a very close alignment between AI predictions and manual measurements, with the average difference between the two methods being -0.259 and -0.243 mm, for bovine liver and chicken breast tissue, respectively., Conclusion: The study validates the Mask2Former model as a promising tool for automating AZ measurement in RFA research, offering a significant step towards reducing manual measurement variability.
- Published
- 2024
- Full Text
- View/download PDF
6. Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial.
- Author
-
Jacques J, Neuhaus H, Enderle MD, Biber U, Linzenbold W, Schenk M, Khalaf K, and Repici A
- Abstract
Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60-65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife
® flex T-Type (HK-T) and the Olympus DualKnife® J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.- Published
- 2023
- Full Text
- View/download PDF
7. Immunomodulatory Effects of Endoscopic Ultrasound-Guided Thermal Ablation in Patients with Pancreatic Ductal Adenocarcinoma.
- Author
-
Testoni SGG, Minici C, Benetti E, Clemente F, Boselli D, Sciorati C, De Monte L, Petrone MC, Enderle M, Linzenbold W, Protti MP, Manfredi A, De Cobelli F, Reni M, Falconi M, Capurso G, Arcidiacono PG, and Della-Torre E
- Abstract
Immunological consequences of endoscopic ultrasound (EUS)-local thermal ablation (LTA) for pancreatic ductal adenocarcinoma (PDAC) have not been extensively assessed. We aimed to explore EUS-LTA effects on the systemic immune response in PDAC. Peripheral blood was collected from 10 treatment-naïve patients with borderline resectable and locally advanced PDAC, randomly allocated to Nab-paclitaxel plus Gemcitabine chemotherapy (CT-arm, n = 5) or EUS-LTA with HybridTherm Probe plus CT (HTP + CT-arm, n = 5). Twenty healthy donors were included as controls. Flow-cytometry and multiplex assays were used to profile immune cell subsets and measure serum cytokines/chemokines, respectively. At baseline, PDAC patients showed increased circulating monocytes and lower circulating lymphocytes and CD19+ B cells counts compared to healthy controls. After 4 months, CT induced decrease of B regulatory cells, CD4+ cytotoxic T cells and IL-1β. The addition of EUS-HTP to CT selectively decreased the serum levels of APRIL/TNFSF13 as well as T regulatory cells, total, classic and inflammatory monocytes. Serum levels of APRIL/TNFSF13 and total, classic and inflammatory monocytes counts at baseline were associated with worse overall survival. EUS-HTP has the potential to selectively impact on immune cells and cytokines associated with poor outcomes in PDAC.
- Published
- 2023
- Full Text
- View/download PDF
8. Bile duct tissue acquisition by cholangioscopy-guided cryobiopsy technique: first-in-human application.
- Author
-
Peveling-Oberhag J, Zimmermann C, Linzenbold W, Ott G, Enderle M, and Albert JG
- Abstract
Video 1Case description and video in cholangioscopic view demonstrating bile duct tissue acquisition by cholangioscopy-guided cryobiopsy technique., (Copyright © 2023 American Society for Gastrointestinal Endoscopy.)
- Published
- 2023
- Full Text
- View/download PDF
9. A new bipolar device for sealing and cutting: ex and in vivo studies for performance evaluation.
- Author
-
Thiel C, Frericks LT, Schenk M, Königsrainer A, Brucker SY, Kraemer B, Steger V, Biber U, Linzenbold W, Enderle MD, and Thiel K
- Subjects
- Swine, Animals, Veins surgery, Ligation, Electrocoagulation, Renal Artery surgery, Hemostasis, Surgical
- Abstract
Introduction: A novel multipurpose bipolar radiofrequency instrument, the Erbe Dissector (EDS), which simultaneously seals and cuts tissue, was developed. Ex vivo sealing rate and time, burst pressure, jaw temperature and thermal spread were studied in porcine renal arteries., Material and Methods: In vivo , 13 surgical tasks were performed in two pigs: beside sealing rate and time, overall performance in sharp and blunt dissection, tissue sticking, hemostasis, precision, etc., were evaluated by four surgeons compared with ENSEAL G2 (EG2) using surveys on a Likert scale (1 = very poor; 5 = very good)., Results: Ex vivo , the EDS sealing rate was 91.7% (33/36 arteries) at an average sealing time of 2.1 s (range 1.7-2.8) and a burst pressure of 1040 ± 350 mmHg. The maximum jaw temperature was 87 ± 4 °C and the mean lateral thermal spread was 0.8 ± 0.2 mm. In vivo , the sealing rate for arteries and veins was 92.6% (50/54) and the median seal and cut time was 1.6 s (range: 1.3-2.9). The average EDS performance score across all tasks was 4.4 ± 0.6 Likert points. For five shared tasks, EDS was better than EG2 (4.4 ± 0.5 versus 3.4 ± 0.6 Likert points; p = 0.016)., Conclusions: EDS seals and cuts arteries and veins rapidly with good safety and user-friendliness.
- Published
- 2022
- Full Text
- View/download PDF
10. EUS-guided ablation with the HybridTherm Probe as second-line treatment in patients with locally advanced pancreatic ductal adenocarcinoma: A case-control study.
- Author
-
Testoni SGG, Petrone MC, Reni M, Di Serio C, Rancoita PM, Rossi G, Balzano G, Linzenbold W, Enderle M, Della-Torre E, De Cobelli F, Falconi M, Capurso G, and Arcidiacono PG
- Abstract
Background and Objectives: Data on the clinical efficacy of EUS-guided ablation using the HybridTherm-Probe (EUS-HTP) in locally advanced pancreatic ductal adenocarcinoma (LA-PDAC) are lacking. The aim of the study was to assess the impact of EUS-HTP added to chemotherapy (CT) on overall survival (OS) and progression-free survival (PFS) of LA-PDAC patients with local disease progression (DP) after first-line therapy, compared to CT alone in controls., Methods: LA-PDAC cases, prospectively treated by EUS-HTP, were retrospectively compared to matched controls (1:2) receiving standard treatment. Study endpoints were the OS and PFS from local DP after first-line therapy, compared through log-rank test calculating hazard ratios and differences in restricted mean OS/PFS time (RMOST/RMPFST) within prespecified time points (4, 6, and 12 months)., Results: Thirteen cases and 26 controls were included. Clinical, tumor, and therapy features before and after first-line therapy were case-control balanced. The median OS and PFS were not significantly improved in cases over controls (months: 7 vs. 5 and 5 vs. 3, respectively). At 4 and 6 months, the RMPFST difference was in favor of cases (P = 0.0001 and P = 0.003, respectively). In cases and controls not candidate to further CT (N = 5 and N = 9), the median OS and PFS were not significantly improved in cases over controls (months: 6 vs. 3 and 4 vs. 2, respectively), but the RMPFST difference was in favor of cases at 4 months (P = 0.002)., Conclusions: In locally progressive PDAC patients experiencing failure of first-line therapy, EUS-HTP achieves a significantly better RMPFST up to 6 months compared to standard treatment, although without a significant impact on OS., Competing Interests: None
- Published
- 2022
- Full Text
- View/download PDF
11. A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy.
- Author
-
Wirsing L, Linzenbold W, Jaeger SU, Stahl P, Ott G, Leibold T, Enderle M, Albert J, and Peveling-Oberhag J
- Abstract
Background and study aims Indeterminate biliary strictures represent a major challenge in clinical diagnostics. Diagnostic yield of radiological, endoscopic imaging and histopathological diagnosis is insufficient. The cryobiopsy technique is a new method for tissue extraction already used in different clinical settings. The aim of this ex vivo clinical study was to investigate feasibility and tissue quality of cryobiopsy in the bile duct. Patients and methods We included 14 patients who underwent pancreaticoduodenectomy. Bile duct samples were taken with either a new prototype cryoprobe or one of two forceps types. Results were analyzed for general feasibility, specimen size, histological assessability as well as representativity of retrieved tissue. Results Feasibility of cholangioscopic forceps was poor compared to gastric biopsy forceps or cryobiopsy. Significantly larger tissue samples were obtained with cryobiopsy (5.6 ± 4.5 mm
2 ) compared to gastric biopsy forceps (3.3 ± 5.1 mm2 , P = 0.006). Furthermore, cryobiopsy was superior in histological assessment quality ( P = 0.02) and concerning representativity ( P = 0.03). Conclusions Cryobiopsy in the bile duct is feasible and the quality of the obtained tissue is high. Further investigation of bile duct cryobiopsy in vivo is warranted., Competing Interests: Competing interests The co-authors Walter Linzenbold and Markus Enderle are employees of ERBE Elektromedizin GmbH, Tuebingen, Germany. Cryoprobes were provided by ERBE Elektromedizin GmbH, Tuebingen, Germany. All other authors have no conflict of interest., (The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).)- Published
- 2022
- Full Text
- View/download PDF
12. Establishment of a Tissue-Mimicking Surrogate for Pulmonary Lesions to Improve the Development of RFA Instruments and Algorithms.
- Author
-
Bühler L, Enderle MD, Kahn N, Polke M, Schneider MA, Heußel CP, Herth FJF, and Linzenbold W
- Abstract
(1) Development of radiofrequency ablation (RFA) systems for pulmonary lesions is restricted by availability of human tumor specimens and limited comparability of animal tissue. We aimed to develop a new surrogate tissue overcoming these drawbacks. (2) Reference values for electrical impedance in lung tumor tissue were collected during routine lung tumor RFA (n = 10). Subsequently, a tissue-mimicking surrogate with comparable electrical impedance and facilitating detection of the ablation margins was developed. (3) The mean electrical impedance for all patients was 103.5 ± 14.7 Ω. In the optimized surrogate tissue model consisting of 68% agar solution, 23% egg yolk, 9% thermochromic ink, and variable amounts of sodium chloride, the mean electrical impedance was adjustable from 74.3 ± 0.4 Ω to 183.2 ± 5.6 Ω and was a function (y = 368.4x + 175.2; R2 = 0.96; p < 0.001) of sodium chloride concentration (between 0 and 0.3%). The surrogate tissue achieved sufficient dimensional stability, and sample cuts revealed clear margins of color change for temperatures higher 60 °C. (4) The tissue-mimicking surrogate can be adapted to lung tumor with respect to its electrical properties. As the surrogate tissue allows for simple and cost-effective manufacturing, it is suitable for extensive laboratory testing of RFA systems for pulmonary ablation.
- Published
- 2022
- Full Text
- View/download PDF
13. Improving the Quality of Human Upper Urinary Tract Specimens by Cryobiopsy.
- Author
-
Klein JT, John A, Bohnert L, Enderle MD, Linzenbold W, and Bolenz C
- Abstract
Objective: The quality of histopathological specimens obtained from the upper urinary tract with conventional flexible ureterorenoscopic biopsy needs to be improved. We investigated the feasibility and biopsy quality of specimens obtained by cryobiopsy, compared with standard ureterorenoscopic biopsy techniques in a human ex vivo model., Materials and Methods: Human ureters obtained from nephrectomy specimens (N=12) were dissected and canulated with an ureteral access sheath. Ureterorenoscopic biopsies were randomly obtained from different sites of the renal pelvic caliceal system using different types of instruments. The performance of two newly developed flexible cryoprobes with outer diameters of 1.1 mm (CB11) and 0.9 mm (CB09) was compared with that of the biopsy forceps(FB) and Bigopsy®(BiG) and two different Dormia baskets N-Gage (NG) and Zero-Tip (ZT). We assessed the feasibility of the various biopsy techniques based on the number of biopsy attempts needed to obtain macroscopically discernible biopsies. The specimens were examined histopathologically for size, biopsy quality, presence of various artifact types, and representativeness., Results: Biopsies taken with the cryoprobes showed a higher biopsy quality than biopsies taken with the comparative instruments. The CB11 provided significantly larger biopsies than forceps biopsies and also than biopsies with ZT. The CB09 was able to collect larger samples when compared with the FB and BiG biopsy forceps. There were no significant differences in artifact area, except for the CB11 cryoprobe compared with the NG. To clarify the results a subdivision of larger or smaller than 20% artifact area was performed. A significant difference was found between CB11 and the forceps biopsies, as well as between CB11 and NG and ZT in favor of the cryoprobe. The representation of the histopathological sample was also determined. Biopsies taken with CB11 were more representative compared with forceps biopsies BiG and FB and basket biopsies NG and ZT., Conclusions: In a standardized comparative ex vivo setting, larger biopsies were obtained by using the cryobiopsy technique with the CB11 probe. Qualitatively, cryobiopsy specimens were overlaid by fewer artifacts and a higher biopsy quality was achieved in histopathologic examination compared with standard instrumentation. Further stepwise development will transfer the promising cryobiopsy technique into the clinical setting., Competing Interests: ME and WL are employed by Erbe Elektromedizin GmbH, Tuebingen Germany. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (Copyright © 2022 Klein, John, Bohnert, Enderle, Linzenbold and Bolenz.)
- Published
- 2022
- Full Text
- View/download PDF
14. Replacing Needle Injection by a Novel Waterjet Technology Grants Improved Muscle Cell Delivery in Target Tissues.
- Author
-
Geng R, Knoll J, Harland N, Amend B, Enderle MD, Linzenbold W, Abruzzese T, Kalbe C, Kemter E, Wolf E, Schenk M, Stenzl A, and Aicher WK
- Subjects
- Animals, Humans, Male, Muscles, Swine, Technology, Urethra, Muscle Cells, Needles
- Abstract
Current regimen to treat patients suffering from stress urinary incontinence often seems not to yield satisfactory improvement or may come with severe side effects. To overcome these hurdles, preclinical studies and clinical feasibility studies explored the potential of cell therapies successfully and raised high hopes for better outcome. However, other studies were rather disappointing. We therefore developed a novel cell injection technology to deliver viable cells in the urethral sphincter complex by waterjet instead of using injection needles. We hypothesized that the risk of tissue injury and loss of cells could be reduced by a needle-free injection technology. Muscle-derived cells were obtained from young male piglets and characterized. Upon expansion and fluorescent labeling, cells were injected into cadaveric tissue samples by either waterjet or injection needle. In other experiments, labeled cells were injected by waterjet in the urethra of living pigs and incubated for up to 7 days of follow-up. The analyses documented that the cells injected by waterjet in vitro were viable and proliferated well. Upon injection in live animals, cells appeared undamaged, showed defined cellular somata with distinct nuclei, and contained intact chromosomal DNA. Most importantly, by in vivo waterjet injections, a significantly wider cell distribution was observed when compared with needle injections ( P < .05, n ≥ 12 samples). The success rates of waterjet cell application in living animals were significantly higher (≥95%, n = 24) when compared with needle injections, and the injection depth of cells in the urethra could be adapted to the need by adjusting waterjet pressures. We conclude that the novel waterjet technology injects viable muscle cells in tissues at distinct and predetermined depth depending on the injection pressure employed. After waterjet injection, loss of cells by full penetration or injury of the tissue targeted was reduced significantly in comparison with our previous studies employing needle injections.
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.