8 results on '"Kochhäuser S"'
Search Results
2. Pre-procedural proton pump inhibition is associated with fewer peri-oesophageal lesions after cryoballoon pulmonary vein isolation
- Author
-
Cordes, F., Ellermann, C., Dechering, D. G., Frommeyer, G., Kochhäuser, S., Lange, P. S., Pott, C., Lenze, F., Kabar, I., Schmidt, H., Ullerich, H., and Eckardt, L.
- Published
- 2021
- Full Text
- View/download PDF
3. Role of catheter location on local impedance measurements and clinical outcome with the new direct sense technology in cardiac ablation procedures
- Author
-
Pesch, E., primary, Riesinger, L., additional, Vonderlin, N., additional, Kupusovic, J., additional, Koehler, M., additional, Bruns, F., additional, Janosi, R.A., additional, Kochhäuser, S., additional, Dobrev, D., additional, Rassaf, T., additional, Wakili, R., additional, and Siebermair, J., additional
- Published
- 2022
- Full Text
- View/download PDF
4. Predictors of Atrial Fibrillation in Patients with Embolic Stroke of Unknown Etiology and Implantable Loop Recorders-Further Insights of the TRACK AF Study on the Role of ECG and Echocardiography.
- Author
-
Höwel D, Leitz P, Frommeyer G, Ritter MA, Reinke F, Füting A, Reinsch N, Eckardt L, Kochhäuser S, and Dechering DG
- Abstract
Aims -Electrocardiography (ECG) and echocardiographic left atrial (LA) parameters may be helpful to assess the risk of atrial fibrillation (AF) in embolic stroke of unknown etiology (ESUS) and could therefore guide intensity of ECG monitoring. Methods -1153 consecutive patients with ischemic stroke or transient ischemic attack (TIA) were analyzed. An internal loop recorder (ILR) was implanted in 104 consecutive patients with ESUS. Multiple morphologic P-wave parameters in baseline 12-channel ECG and echocardiographic LA parameters were measured and analyzed in patients with and without ILR-detected AF. Using logistic regression, we evaluated the predictive value of several ECG parameters and LA dimensions on the occurrence of AF. Results -In 20 of 104 (19%) patients, AF was diagnosed by ILR during a mean monitoring time of 575 (IQR 470-580) days. Patients with AF were significantly older (72 (67-75) vs. 60 (52-72) years; p = 0.001) and premature atrial contractions (PAC) were more frequently observed (40% vs. 2%; p < 0.001) during baseline ECG. All morphologic P-wave parameters did not show a significant difference between groups. There was a non-significant trend towards a larger LA volume index (31 (24-36) vs. 29 (25-37) mL/m
2 ; p = 0.09) in AF patients. Conclusions -Age and PAC are independently associated with incident AF in ESUS and could be used as markers for selecting patients that may benefit from more extensive rhythm monitoring or ILR implantation. In our consecutive cohort of patients with ESUS, neither morphological P-wave parameters nor LA size were predictive of AF.- Published
- 2023
- Full Text
- View/download PDF
5. Progression of Atrial Fibrillation after Cryoablation or Drug Therapy.
- Author
-
Andrade JG, Deyell MW, Macle L, Wells GA, Bennett M, Essebag V, Champagne J, Roux JF, Yung D, Skanes A, Khaykin Y, Morillo C, Jolly U, Novak P, Lockwood E, Amit G, Angaran P, Sapp J, Wardell S, Lauck S, Cadrin-Tourigny J, Kochhäuser S, and Verma A
- Subjects
- Humans, Recurrence, Tachycardia etiology, Treatment Outcome, Disease Progression, Follow-Up Studies, Anti-Arrhythmia Agents adverse effects, Anti-Arrhythmia Agents therapeutic use, Atrial Fibrillation drug therapy, Atrial Fibrillation etiology, Catheter Ablation adverse effects, Catheter Ablation methods, Cryosurgery adverse effects, Cryosurgery methods
- Abstract
Background: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation., Methods: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected., Results: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group., Conclusions: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.)., (Copyright © 2022 Massachusetts Medical Society.)
- Published
- 2023
- Full Text
- View/download PDF
6. Role of catheter location on local impedance measurements and clinical outcome with the new direct sense technology in cardiac ablation procedures.
- Author
-
Pesch E, Riesinger L, Vonderlin N, Kupusovic J, Koehler M, Bruns F, Janosi RA, Kochhäuser S, Dobrev D, Rassaf T, Wakili R, and Siebermair J
- Abstract
Background: A novel catheter technology (direct sense, DS) enables periprocedural local impedance (LI) measurement for estimation of tissue contact during radiofrequency ablation (RFA) for real-time assessment of lesion generation. This measure reflects specific local myocardial conduction properties in contrast to the established global impedance (GI) using a neutral body electrode. Our study aimed to assess representative LI values for the cardiac chambers, to evaluate LI drop in response to RF delivery and to compare those values to established GI measures in patients undergoing RFA procedures., Methods and Results: Seventy-three patients undergoing RFA with the DS technology were included. Within the cardiac chambers, baseline LI was significantly different, with the highest values in the left atrium (LA 107.5 ± 14.3 Ω; RV 104.6 Ω ± 12.9 Ω; LV 100.7 Ω ± 11.7 Ω, and RA 100.5 Ω ± 13.4 Ω). Baseline LI was positively correlated to the corresponding LI drop during RF delivery (R
2 = 0.26, p = 0.01) representing a promising surrogate of lesion generation. The observed mean LI drop (15.6 ± 9.5 Ω) was threefold higher as GI drop (4.9 ± 7.4 Ω), p < 0.01. We evaluated the clinical outcome in a subgroup of patients undergoing DS-guided pulmonary vein isolation, which was comparable regarding arrhythmia recurrence to a conventional ablation cohort (57 % vs 50 %, p = 0.2)., Conclusion: We provide detailed information on LI measures in electrophysiological procedures with significant differences within the cardiac chambers highlighting that RFA-related LI drop can serve as a promising surrogate for real-time assessment of lesion generation. Guiding the electrophysiologist in RFA procedures, this additional information promises to improve safety profile and success rates in the interventional treatment of arrhythmias., Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (© 2022 The Authors.)- Published
- 2022
- Full Text
- View/download PDF
7. Visualization of thermal damage using 68 Ga-FAPI-PET/CT after pulmonary vein isolation.
- Author
-
Kupusovic J, Kessler L, Nekolla SG, Riesinger L, Weber MM, Ferdinandus J, Kochhäuser S, Rassaf T, Wakili R, Rischpler C, and Siebermair J
- Subjects
- Gallium Radioisotopes, Humans, Positron Emission Tomography Computed Tomography, Positron-Emission Tomography, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Pulmonary Veins diagnostic imaging, Pulmonary Veins surgery
- Abstract
Purpose:
68 Ga-fibroblast-activation protein inhibitor (FAPI) positron emission tomography (PET) is a novel technique targeting FAP-alpha. This protein is expressed by activated fibroblasts which are the main contributors to tissue remodeling. The aim of this proof-of-concept study was to assess68 Ga-FAPI uptake in the pulmonary vein (PV) region of the left atrium after pulmonary vein isolation (PVI) with cryoballoon ablation (CBA) and radiofrequency (RFA) as a surrogate for thermal damage., Methods: Twelve PVI patients (5 RFA, 7 CBA) underwent68 Ga-FAPI-PET 20.5 ± 12.8 days after PVI. Five patients without atrial fibrillation or previous ablation served as controls. Standardized uptake values of localized tracer uptake were calculated., Results: Focal FAPI uptake around the PVs was observed in 10/12 (83.3%) PVI patients, no uptake was observed in 2 PVI patients and all controls. Patients after PVI had higher FAPI uptake in PVs compared to controls (SUVmax : 4.3 ± 2.2 vs. 1.6 ± 0.2, p < 0.01; SUVpeak : 2.9 ± 1.4 vs. 1.3 ± 0.2, p < 0.01). All CBA patients had an intense uptake, while in the RFA, group 2 (40%), 1 (20%), and 2 (40%) patients had an intense, moderate, and no uptake, respectively. We observed higher uptake values (SUVpeak ) in CBA compared to RFA patients (4.4 ± 1.5 vs. 2.5 ± 0.8, p = 0.02)., Conclusion: We demonstrate in-vivo visualization of68 Ga-FAPI uptake as a surrogate for fibroblast activation after PVI. CBA seems to cause more pronounced fibroblast activation following tissue injury than RFA. Future studies are warranted to assess if this modality can contribute to a better understanding of the mechanisms of AF recurrence after PVI by lesion creation and gap assessment., (© 2021. The Author(s).)- Published
- 2022
- Full Text
- View/download PDF
8. Catheter Ablation of Atrial Fibrillation in Patients with Previous Lobectomy or Partial Lung Resection: Long-Term Results of an International Multicenter Study.
- Author
-
Demarchi A, Conte G, Chen SA, Lo LW, Chen WT, De Potter T, Geelen P, Sarkozy A, Spera FR, Reichlin T, Roten L, Defaye P, Carabelli A, Boveda S, Bourenane H, Riesinger L, Kochhäuser S, Caixal G, Mont L, Scherr D, Manninger M, Pentimalli F, Cornara S, Klersy C, and Auricchio A
- Abstract
Introduction: Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients' previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of patients., Material and Methods: Twenty consecutive patients (8 females, 40%; median age 65.2 years old) with a history of pneumonectomy/lobectomy and paroxysmal or persistent AF, treated by means of pulmonary vein isolation (PVI) at ten participating centers were included. Procedural success, intra-procedural complications, and AF recurrences were considered., Results: Fifteen patients had a previous lobectomy and five patients had a complete pneumonectomy. A large proportion (65%) of PV stumps were electrically active and represented a source of firing in 20% of cases. PVI was performed by radiofrequency ablation in 13 patients (65%) and by cryoablation in the remaining 7 cases. Over a median follow up of 29.7 months, a total of 7 (33%) AF recurrences were recorded with neither a difference between patients treated with cryoablation or radiofrequency ablation or between the two genders., Conclusions: Catheter ablation by radiofrequency ablation or cryoablation in patients with pulmonary stumps is feasible and safe. Long-term outcomes are favorable, and a similar efficacy of catheter ablation has been noticed in both males and females.
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.