6 results on '"Hofman MBM"'
Search Results
2. Clinical implementation of a fully automated quantitative perfusion cardiovascular magnetic resonance imaging workflow with a simplified dual-bolus contrast administration scheme.
- Author
-
Borodzicz-Jazdzyk S, Vink CEM, Demirkiran A, Hoek R, de Mooij GW, Hofman MBM, Wilgenhof A, Appelman Y, Benovoy M, and Götte MJW
- Subjects
- Humans, Female, Male, Middle Aged, Aged, Magnetic Resonance Imaging methods, Coronary Angiography methods, Myocardial Perfusion Imaging methods, Gadolinium administration & dosage, Contrast Media administration & dosage, Workflow, Coronary Artery Disease diagnostic imaging
- Abstract
This study clinically implemented a ready-to-use quantitative perfusion (QP) cardiovascular magnetic resonance (QP CMR) workflow, encompassing a simplified dual-bolus gadolinium-based contrast agent (GBCA) administration scheme and fully automated QP image post-processing. Twenty-five patients with suspected obstructive coronary artery disease (CAD) underwent both adenosine stress perfusion CMR and an invasive coronary angiography or coronary computed tomography angiography. The dual-bolus protocol consisted of a pre-bolus (0.0075 mmol/kg GBCA at 0.5 mmol/ml concentration + 20 ml saline) and a main bolus (0.075 mmol/kg GBCA at 0.5 mmol/ml concentration + 20 ml saline) at an infusion rate of 3 ml/s. The arterial input function curves showed excellent quality. Stress MBF ≤ 1.84 ml/g/min accurately detected obstructive CAD (area under the curve 0.79; 95% Confidence Interval: 0.66 to 0.89). Combined visual assessment of color pixel QP maps and conventional perfusion images yielded a diagnostic accuracy of 84%, sensitivity of 70% and specificity of 93%. The proposed easy-to-use dual-bolus QP CMR workflow provides good image quality and holds promise for high accuracy in diagnosis of obstructive CAD. Implementation of this approach has the potential to serve as an alternative to current methods thus increasing the accessibility to offer high-quality QP CMR imaging by a wide range of CMR laboratories., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
3. Performance of Image-navigated and Diaphragm-navigated 3D Late Gadolinium-enhanced Cardiac MRI for the Assessment of Atrial Fibrosis.
- Author
-
Hopman LHGA, Solís-Lemus JA, Hofman MBM, Bhagirath P, Borodzicz-Jazdzyk S, van Pouderoijen N, Krafft AJ, Schmidt M, Allaart CP, Niederer SA, and Götte MJW
- Subjects
- Aged, Humans, Male, Middle Aged, Contrast Media, Gadolinium, Heart Atria diagnostic imaging, Magnetic Resonance Imaging, Prospective Studies, Female, Atrial Fibrillation diagnosis, Diaphragm
- Abstract
Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.
- Published
- 2024
- Full Text
- View/download PDF
4. MRI in patients with a cerebral aneurysm clip; review of the literature and incident databases and recommendations for the Netherlands.
- Author
-
Hofman MBM, Lavini C, van der Zwan A, van Pul C, Muller SH, Stam MK, van der Graaf M, Kloeze C, van Nierop BJ, Kappert P, and Kuijer JPA
- Subjects
- Humans, Netherlands, Magnetic Resonance Imaging methods, Surgical Instruments, Prostheses and Implants, Intracranial Aneurysm diagnostic imaging, Intracranial Aneurysm surgery
- Abstract
Background: In the past ferromagnetic cerebral aneurysm clips that are contraindicated for Magnetic Resonance Imaging (MRI) have been implanted. However, the specific clip model is often unknown for older clips, which poses a problem for individual patient management in clinical care., Methods: Literature and incident databases were searched, and a survey was performed in the Netherlands that identified time periods at which ferromagnetic and non-ferromagnetic clip models were implanted. Considering this information in combination with a national expert opinion, we describe an approach for risk assessment prior to MRI examinations in patients with aneurysm clips. The manuscript is limited to MRI at 1.5 T or 3 T whole body MRI systems with a horizontal closed bore superconducting magnet, covering the majority of clinical Magnetic Resonance (MR) systems., Results: From the literature a list of ferromagnetic clip models was obtained. The risk of movement or rotation of the clip due to the main magnetic field in case of a ferromagnetic clip is the main concern. In the incident databases records of four serious incidents due to aneurysm clips in MRI were found. The survey in the Netherlands showed that from 2000 onwards, no ferromagnetic clips were implanted in Dutch hospitals., Discussion: Recommendations are provided to help the MR safety expert assessing the risks when a patient with a cerebral aneurysm clip is referred for MRI, both for known and unknown clip models. This work was part of the development of a guideline by the Dutch Association of Medical Specialists., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
5. Clinical intra-cardiac 4D flow CMR: acquisition, analysis, and clinical applications.
- Author
-
Demirkiran A, van Ooij P, Westenberg JJM, Hofman MBM, van Assen HC, Schoonmade LJ, Asim U, Blanken CPS, Nederveen AJ, van Rossum AC, and Götte MJW
- Subjects
- Blood Flow Velocity physiology, Humans, Magnetic Resonance Imaging, Predictive Value of Tests, Cardiovascular System, Image Interpretation, Computer-Assisted methods
- Abstract
Identification of flow patterns within the heart has long been recognized as a potential contribution to the understanding of physiological and pathophysiological processes of cardiovascular diseases. Although the pulsatile flow itself is multi-dimensional and multi-directional, current available non-invasive imaging modalities in clinical practice provide calculation of flow in only 1-direction and lack 3-dimensional volumetric velocity information. Four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR) has emerged as a novel tool that enables comprehensive and critical assessment of flow through encoding velocity in all 3 directions in a volume of interest resolved over time. Following technical developments, 4D flow CMR is not only capable of visualization and quantification of conventional flow parameters such as mean/peak velocity and stroke volume but also provides new hemodynamic parameters such as kinetic energy. As a result, 4D flow CMR is being extensively exploited in clinical research aiming to improve understanding of the impact of cardiovascular disease on flow and vice versa. Of note, the analysis of 4D flow data is still complex and accurate analysis tools that deliver comparable quantification of 4D flow values are a necessity for a more widespread adoption in clinic. In this article, the acquisition and analysis processes are summarized and clinical applications of 4D flow CMR on the heart including conventional and novel hemodynamic parameters are discussed. Finally, clinical potential of other emerging intra-cardiac 4D flow imaging modalities is explored and a near-future perspective on 4D flow CMR is provided., (© The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology.)
- Published
- 2022
- Full Text
- View/download PDF
6. Comparison between cardiac magnetic resonance stress T1 mapping and [15O]H2O positron emission tomography in patients with suspected obstructive coronary artery disease.
- Author
-
Everaars H, van Diemen PA, Biesbroek PS, Hopman LHGA, Bom MJ, Schumacher SP, de Winter RW, van de Ven PM, Raijmakers PG, Lammertsma AA, Hofman MBM, Nijveldt R, Götte MJ, van Rossum AC, Danad I, Driessen RS, and Knaapen P
- Subjects
- Contrast Media, Coronary Circulation, Gadolinium, Humans, Magnetic Resonance Spectroscopy, Oxygen Radioisotopes, Positron-Emission Tomography methods, Coronary Artery Disease diagnostic imaging, Myocardial Perfusion Imaging methods
- Abstract
Aims: To compare cardiac magnetic resonance (CMR) measurement of T1 reactivity (ΔT1) with [15O]H2O positron emission tomography (PET) measurements of quantitative myocardial perfusion., Methods and Results: Forty-three patients with suspected obstructed coronary artery disease underwent [15O]H2O PET and CMR at 1.5-T, including rest and adenosine stress T1 mapping (ShMOLLI) and late gadolinium enhancement to rule out presence of scar tissue. ΔT1 was determined for the three main vascular territories and compared with [15O]H2O PET-derived regional stress myocardial blood flow (MBF) and myocardial flow reserve (MFR). ΔT1 showed a significant but poor correlation with stress MBF (R2 = 0.04, P = 0.03) and MFR (R2 = 0.07, P = 0.004). Vascular territories with impaired stress MBF (i.e. ≤2.30 mL/min/g) demonstrated attenuated ΔT1 compared with vascular territories with preserved stress MBF (2.9 ± 2.2% vs. 4.1 ± 2.2%, P = 0.008). In contrast, ΔT1 did not differ between vascular territories with impaired (i.e. <2.50) and preserved MFR (3.2 ± 2.6% vs. 4.0 ± 2.1%, P = 0.25). Receiver operating curve analysis of ΔT1 resulted in an area under the curve of 0.66 [95% confidence interval (CI): 0.57-0.75, P = 0.009] for diagnosing impaired stress MBF and 0.62 (95% CI: 0.53-0.71, P = 0.07) for diagnosing impaired MFR., Conclusions: CMR stress T1 mapping has poor agreement with [15O]H2O PET measurements of absolute myocardial perfusion. Stress T1 and ΔT1 are lower in vascular territories with reduced stress MBF but have poor accuracy for detecting impaired myocardial perfusion., (Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2021. For permissions, please email: journals.permissions@oup.com.)
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.