1. Comparison of Sinus Deposition from an Aqueous Nasal Spray and Pressurised MDI in a Post-Endoscopic Sinus Surgery Nasal Replica.
- Author
-
Siu J, van Strien J, Campbell R, Roberts P, Tingle MD, Inthavong K, and Douglas RG
- Subjects
- Administration, Inhalation, Drug Compounding, Female, Fluticasone chemistry, Fluticasone metabolism, Glucocorticoids chemistry, Glucocorticoids metabolism, Humans, Metered Dose Inhalers, Middle Aged, Nasal Sprays, Paranasal Sinuses anatomy & histology, Paranasal Sinuses surgery, Printing, Three-Dimensional, Tissue Distribution, Transanal Endoscopic Surgery, Fluticasone administration & dosage, Glucocorticoids administration & dosage, Models, Anatomic, Paranasal Sinuses metabolism
- Abstract
Background: Optimising intranasal distribution and retention of topical therapy is essential for effectively managing patients with chronic rhinosinusitis, including those that have had functional endoscopic sinus surgery (FESS). This study presents a new technique for quantifying in vitro experiments of fluticasone propionate deposition within the sinuses of a 3D-printed model from a post-FESS patient., Methods: Circular filter papers were placed on the sinus surfaces of the model. Deposition of fluticasone on the filter paper was quantified using high-performance liquid chromatography (HPLC) assay-based techniques. The deposition patterns of two nasal drug delivery devices, an aqueous nasal spray (Flixonase) and metered dose inhaler (Flixotide), were compared. The effects of airflow (0 L/min vs. 12 L/min) and administration angle (30° vs. and 45°) were evaluated., Results: Inhaled airflow made little difference to sinus deposition for either device. A 45° administration angle improved frontal sinus deposition with the nasal spray and both ethmoidal and sphenoidal deposition with the inhaler. The inhaler provided significantly better deposition within the ethmoid sinuses (8.5x) and within the maxillary sinuses (3.9x) compared with the nasal spray under the same conditions., Conclusion: In the post-FESS model analysed, the inhaler produced better sinus deposition overall compared with the nasal spray. The techniques described can be used and adapted for in vitro performance testing of different drug formulations and intranasal devices under different experimental conditions. They can also help validate computational fluid dynamics modelling and in vivo studies., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF