6 results on '"Câmara anterior"'
Search Results
2. Anti-inflammatory treatment after selective laser trabeculoplasty: a systematic review of the literature and meta-analysis of randomized control trials.
- Author
-
Panagiotis, Dervenis, Nikolaos, Dervenis, Dimitrios, Chiras, and Panagiotis, Vasilakis
- Subjects
TRABECULECTOMY ,FIXED effects model ,INTRAOCULAR pressure ,LASER therapy ,ANTI-inflammatory agents ,LASERS ,RANDOMIZED controlled trials ,STEROID drugs - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
3. HIPERTENSÃO OCULAR SECUNDÁRIA À LUXAÇÃO DE CRISTALINO PARA CÂMARA ANTERIOR NA SÍNDROME DE MARFAN
- Author
-
Daniel Prado Beraldo, Fernando Buzatto Mantovan, and Emanuele Moraes Mello
- Subjects
síndrome de Marfan ,ectopia do cristalino ,hipertensão ocular ,câmara anterior ,Medicine (General) ,R5-920 - Abstract
A síndrome de Marfan (SMF) é uma rara desordem metabólica autossômica dominante, causada por mutações no gene responsável pela codificação da proteína fibrilina-1. Caracteriza-se por manifestações cardiovasculares, musculoesqueléticas e oculares. O objetivo desse relato foi apresentar uma complicação oftalmológica rara em paciente portadora da SMF. Feminino, 51 anos, compareceu ao pronto socorro com queixa de dor intensa, baixa acuidade visual (AV) e hiperemia em olho direito (OD), há dois dias. Biomicroscopia: ectopia do cristalino (luxação) para câmara anterior; Tonometria: 56 mmHg. Foi prescrito medicamentos hipotensores, que reduziram a pressão intraocular (PIO) para 8 mmHg. Encaminhada para cirurgia de urgência (facectomia sem implante de LIO) a fim de evitar maiores danos à córnea e ao nervo óptico. No pós operatório, apresentou controle da PIO e melhora da AV para 20/50. Na SMF se faz necessário o acompanhamento multidisciplinar, possibilitando diagnósticos precoces, o que pode prevenir e minimizar eventuais complicações.
- Published
- 2022
4. Agreement of Vault Size Measurements between the Pentacam®, the Anterion® and the Spectralis®
- Author
-
Castro, Catarina, Abreu, Ana Carolina, Monteiro, Sílvia, and Pinto, Maria do Céu
- Subjects
Câmara Anterior ,Implante de Lente Intraocular ,Lens Implantation, Intraocular ,Anterior Chamber - Abstract
Introduction: Despite good refractive results, implantable collamer lens (ICL) implantation may lead to postoperative complications. One indicator of its safety is the vault size. Our purpose was to evaluate the agreement of vault size measurements between the Pentacam®, the Anterion® and the Spectralis®.Methods: Cross-sectional analysis of eyes previously submitted to ICL implantation. Vault size was evaluated with the Pentacam® HR, the Anterion® and the Spectralis® (anterior segment). Secondarily, the anterior chamber depth (ACD) was evaluated with the Pentacam® and the Anterion®. Images of the same patient were performed on the same day, by the same technician. Vault and ACD measurements were performed by two refractive surgeons. Images were randomly divided into three groups and each group was analyzed one week apart, by each observer, with images in a randomized order.Results: Fifty-five eyes (30 patients) were included. The intraclass correlation coefficient (ICC) for absolute agreement and consistency of vault measurements was good to excellent. The vault measurements obtained with Pentacam® were inferior to those obtained with the Anterion® and the Spectralis® (p0.697). The differences in the vault measurements between the Anterion® and the Pentacam® correlated positively with the increase of the vault size in the Anterion® (p, Introdução: Apesar dos bons resultados refrativos, o implante de implantable collamer lens (ICL) pode levar a complicações pós-operatórias. Um indicador da sua segurança é o tamanho do vault. O nosso objetivo foi avaliar a concordância nas medições do vault entre o Pentacam®, o Anterion® e o Spectralis®. Métodos: Análise transversal de olhos previamente submetidos a implante de ICL. O vault foi avaliado com o Pentacam® HR, o Anterion® e o Spectralis® (segmento anterior). Secundariamente, a profundidade da câmara anterior (ACD) foi avaliada com o Pentacam® e o Anterion®. As imagens do mesmo paciente foram realizadas no mesmo dia, pelo mesmo técnico. As medições do vault e da ACD foram realizadas por dois cirurgiões refrativos experientes. As imagens foram divididas aleatoriamente em três grupos e cada grupo foi analisado com uma semana de intervalo, por cada observador, com imagens em ordem aleatória. Resultados: Foram incluídos 55 olhos (30 doentes). O coeficiente de correlação intraclasse (ICC) para a concordância absoluta e a consistência das medições do vault foi bom a excelente. As medições do vault obtidas com Pentacam® foram inferiores às obtidas com o Anterion® e o Spectralis® (p
- Published
- 2023
5. Instabilidade do filme lacrimal e perda de glândulas meibomianas em pacientes com acne vulgaris
- Author
-
Acet,Yakup and Bilik,Leyla
- Subjects
Noninvasive break-up time test ,Ophthalmology ,Meibomian glands ,Acne vulgaris ,General Medicine ,Acne vulgar ,Filme lacrimal ,Teste não-invasivo de tempo de ruptura ,Anterior chamber ,Tear film ,Glândulas de Meibomius ,Câmara anterior - Abstract
Purpose: In this prospective study, we compared ocular clinical variables in patients with acne vulgaris with those of healthy controls. These variables included tear film break-up time, meibomian gland dropout rate, and anterior chamber parameters. Methods: Our sample comprised 73 eyes from 73 patients with acne vulgaris and 67 eyes from 67 healthy controls. All participants underwent a non-invasive first tear film break-up time test and the average tear film break-up time was evaluated. Meibography was used to identify any meibomian gland dropout. The parameters of the cornea and anterior chamber were measured using Scheimpflug topography imaging. Finally, the ocular surface disease index questionnaire was administered to score each participant on their subjective experience of ocular complaints. Results: The noninvasive first tear film break-up time values of the acne vulgaris Group and the control Group were 4.7 ± 2.8 and 6.4 ± 3.5 sec, respectively. There was a significant difference between the groups (p=0.016). The number of eyes with tear break-up at any time during the measurement period was also significantly higher in the acne Group (p=0.018). In the acne vulgaris Group, the mean meibomian gland dropout rates were 33.21 ± 15.5% in the upper lids and 45.4 ± 14.5% in the lower lids. In the control group, these rates were 15.7 ± 6.9% and 21 ± 9.7% respectively. Dropout was significantly higher in the acne group for both the upper and lower lids (p=0.000). Conclusion: We found impaired tear stability in patients with acne vulgaris and a high rate of meibomian gland dropout. These glands play a key role in tear stability and their dropout is likely to result in evaporative dry eye. Measurement of the variables in this study allows objective diagnosis of this condition using a non-invasive, dye-free methodology, with minimum contact. RESUMO Objetivo: Neste estudo prospectivo, pacientes com acne vulgaris e indivíduos saudáveis do grupo controle foram comparados em relação ao tempo de ruptura do filme lacrimal, taxa de abandono de glândulas meibomianas e parâmetros da câmara anterior, usando o tempo de ruptura do filme lacrimal topográfico não invasivo, meibografia não invasiva e fotografia de Scheimpflug, respectivamente. Métodos: Setenta e três olhos de 73 pacientes com acne vulgaris e 67 olhos de 67 indivíduos saudáveis foram incluídos. Todos os participantes submetidos ao primeiro tempo de ruptura do filme lacrimal não-invasivo e ao tempo médio de ruptura do filme lacrimal não-invasivo foram avaliados pelo uso do tempo de ruptura do filme lacrimal; perda de glândulas meibomianas foram avaliadas por meibografia; os parâmetros da córnea e da câmara anterior foram medidos por fotografia de Scheimpflug; e, finalmente, as queixas oculares subjetivas foram pontuadas com o uso do questionário do Indice de doenças de superfície ocular. Resultados: Os valores do tempo de ruptura do primeiro filme lacrimal não-invasivo do Grupo com acne vulgaris e do Grupo controle foram 4,7 ± 2,8 e 6,4 ± 3,5 segundos, respectivamente, refererindo-se a uma diferença significativa entre os valores dos grupos (p=0,016). Qualitativamente, o número de olhos com ruptura lacrimal a qualquer momento durante o período de medição foi significativamente maior no grupo de pacientes. (p=0,018). No Grupo com acne vulgaris, a perda de glândulas meibomianas nas pálpebras superiores foi de 33,21 ± 15,5% e nas pálpebras inferiores foi de 45,4 ± 14,5%; por outro lado, no Grupo controle foi de 15,7 ± 6,9% e 21 ± 9,7% respectivamente; ambos os casos referem-se a uma diferença significativa entre os grupos (p=0,000). Conclusão: Encontramos estabilidade comprometida do filme lacrimal em pacientes com acne vulgaris. No entanto, o comprometimento foi de grau muito menor, em comparação com a taxa de perda das glândulas meibomianas que desempenham um papel fundamental na estabilidade do filme lacrimal. Esta condição pode ser documentada de forma objetiva - uma metodologia parcialmente sem contato, totalmente não-invasiva e livre de corantes.
- Published
- 2022
6. A Boy with a Growing Mass in the Anterior Chamber
- Author
-
Leuzinger-Dias, Mariana, Fernandes, Vítor, and Freitas-da-Costa, Paulo
- Subjects
Câmara Anterior ,genetic structures ,Iris Diseases ,Anterior Chamber ,Cysts ,sense organs ,Doenças da Íris ,eye diseases ,Quistos - Abstract
An 18-year-old boy presented to our emergency department with a 1-month history of a painful left eye, photophobia, and progressive blurring of vision. His past ocular history included a penetrating left globe injury, surgically repaired 1 year before. Biomicroscopy revealed a scar in the inferior cornea and a huge epithelial iris cyst, reaching the visual axis (Panel A). BCVA of the left eye was 20/320, and intraocular pressure was 20 mmHg. Further investigation, namely ultrasound biomicroscopy (Panel B), and anterior segment-OCT (not shown) supported this diagnosis. Nd: YAG laser cystotomy was performed to rupture the cyst wall and drain its fluid content. Immediate shrinkage of the cyst was seen, but additional follow-up is required to rule out the development of procedure-related complications and cyst recurrence. With the evolution of surgical techniques, posttraumatic iris cysts have become rare entities. Nevertheless, its recognition and management are mandatory for any ophthalmologist.
- Published
- 2022
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.